{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/55063"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/55063","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Analysis and design of a high temperature liquid metal solar thermal receiver","abstract":"Current concentrated solar technologies are not cost-effective means of generating electricity and would benefit greatly from higher operating temperatures. To reach these temperatures at high efficiencies, a novel receiver design should be used in the plant. As a first step in the design of such a receiver, a sensitivity analysis is useful to determine what parameters most affect the performance of a generic cavity receiver. The results of this sensitivity analysis can be used to develop an optimized cavity receiver geometry intended to operate at a high efficiency (>80%) at extreme temperatures (1,350°C). It was found that limiting re-radiation and convection through the cavity aperture most improve the performance of the receiver; at the same time, the receiver must be designed in such a way as to minimize thermal stresses. Descriptions of many experimental components that have been developed to allow for a successful test of a laboratory scale receiver are also included in this thesis. Additionally, presented here are the results of some initial experiments intended to validate the simulations used to perform the aforementioned sensitivity analysis. Finally, some remarks are proffered detailing additional steps and considerations necessary to scale up the receiver design to an industrial scale.","abstract_html":"Current concentrated solar technologies are not cost-effective means of generating electricity and would benefit greatly from higher operating temperatures. To reach these temperatures at high efficiencies, a novel receiver design should be used in the plant. As a first step in the design of such a receiver, a sensitivity analysis is useful to determine what parameters most affect the performance of a generic cavity receiver. The results of this sensitivity analysis can be used to develop an optimized cavity receiver geometry intended to operate at a high efficiency (&gt;80%) at extreme temperatures (1,350°C). It was found that limiting re-radiation and convection through the cavity aperture most improve the performance of the receiver; at the same time, the receiver must be designed in such a way as to minimize thermal stresses. Descriptions of many experimental components that have been developed to allow for a successful test of a laboratory scale receiver are also included in this thesis. Additionally, presented here are the results of some initial experiments intended to validate the simulations used to perform the aforementioned sensitivity analysis. Finally, some remarks are proffered detailing additional steps and considerations necessary to scale up the receiver design to an industrial scale.","abstract_has_math":false,"creators":["Deangelis, Alfred N."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Henry, Asegun"],"committee_chairs":[],"committee_members":["Yee, Shannon","Graham, Samuel"],"year":2016,"date_issued":"2016-05-03","date_published":"2016-05-03","updated_at":"2026-11-19T04:07:03Z","subjects":["Solar","Liquid metal","Heat transfer","Energy"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/55063","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/55063","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F55063","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Henry, Asegun"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Yee, Shannon","Graham, Samuel"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Deangelis, Alfred N."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-05-27T13:25:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-05-27T13:25:14Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-05"]},{"key":"dc:date.issued","label":"Date","values":["2016-05-03"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2016"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2016-05-27T13:25:14Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["George W. Woodruff School of Mechanical Engineering Annual Distinguished Lectures","Master of Science in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["e749c709-2d0f-4c52-99a4-0934066ee2f5","028ba2d8-6c6e-4f8a-a480-51b555d14e9d"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Solar","Liquid metal","Heat transfer","Energy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/55063"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Current concentrated solar technologies are not cost-effective means of generating electricity and would benefit greatly from higher operating temperatures. To reach these temperatures at high efficiencies, a novel receiver design should be used in the plant. As a first step in the design of such a receiver, a sensitivity analysis is useful to determine what parameters most affect the performance of a generic cavity receiver. The results of this sensitivity analysis can be used to develop an optimized cavity receiver geometry intended to operate at a high efficiency (>80%) at extreme temperatures (1,350°C). It was found that limiting re-radiation and convection through the cavity aperture most improve the performance of the receiver; at the same time, the receiver must be designed in such a way as to minimize thermal stresses. Descriptions of many experimental components that have been developed to allow for a successful test of a laboratory scale receiver are also included in this thesis. Additionally, presented here are the results of some initial experiments intended to validate the simulations used to perform the aforementioned sensitivity analysis. Finally, some remarks are proffered detailing additional steps and considerations necessary to scale up the receiver design to an industrial scale."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Analysis and design of a high temperature liquid metal solar thermal receiver"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Henry, Asegun"],"dc:contributor.committeemember":["Yee, Shannon","Graham, Samuel"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Deangelis, Alfred N."],"dc:date.accessioned":["2016-05-27T13:25:14Z"],"dc:date.available":["2016-05-27T13:25:14Z"],"dc:date.created":["2016-05"],"dc:date.issued":["2016-05-03"],"dc:date.submitted":["May 2016"],"dc:date.updated":["2016-05-27T13:25:14Z"],"dc:description.abstract":["Current concentrated solar technologies are not cost-effective means of generating electricity and would benefit greatly from higher operating temperatures. To reach these temperatures at high efficiencies, a novel receiver design should be used in the plant. As a first step in the design of such a receiver, a sensitivity analysis is useful to determine what parameters most affect the performance of a generic cavity receiver. The results of this sensitivity analysis can be used to develop an optimized cavity receiver geometry intended to operate at a high efficiency (>80%) at extreme temperatures (1,350°C). It was found that limiting re-radiation and convection through the cavity aperture most improve the performance of the receiver; at the same time, the receiver must be designed in such a way as to minimize thermal stresses. Descriptions of many experimental components that have been developed to allow for a successful test of a laboratory scale receiver are also included in this thesis. Additionally, presented here are the results of some initial experiments intended to validate the simulations used to perform the aforementioned sensitivity analysis. Finally, some remarks are proffered detailing additional steps and considerations necessary to scale up the receiver design to an industrial scale."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/55063"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["George W. Woodruff School of Mechanical Engineering Annual Distinguished Lectures","Master of Science in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["e749c709-2d0f-4c52-99a4-0934066ee2f5","028ba2d8-6c6e-4f8a-a480-51b555d14e9d"],"dc:subject":["Solar","Liquid metal","Heat transfer","Energy"],"dc:title":["Analysis and design of a high temperature liquid metal solar thermal receiver"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T04:07:03Z"}