{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/55536"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/55536","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Magnetic resonance imaging of intraspinal stem cell grafts: Tracking and targeted transplantation","abstract":"Transplantation of cellular therapeutics into the spinal cord has been explored as treatment for a range of degenerative and traumatic diseases. The post-transplantation fate of cellular therapeutics is poorly understood in both large animal models and in human studies because of limitations in cell graft detection. A minimally invasive technology for cellular graft tracking to visualize grafts in vivo is needed. However, it is important that the diagnostic marker does not impact the engraftment or efficacy of transplanted cells. We developed a straightforward, rapidly translatable method to label human neural progenitor/stem cells with magnetic ferumoxytol nanoparticles. We investigated the potential effect of ferumoxytol labeling on biological properties of the cells and transplanted them into a large animal (porcine) spinal cord. We assessed the feasibility and safety of in vivo diagnostic cell graft tracking using Magnetic Resonance Imaging and post-mortem histological identification in a clinically relevant model. Furthermore, we leveraged this tracking approach to develop and assess a minimally invasive, Magnetic Resonance Imaging-guided technique for targeted intraspinal stem cell graft transplantation in a large animal model.","abstract_html":"Transplantation of cellular therapeutics into the spinal cord has been explored as treatment for a range of degenerative and traumatic diseases. The post-transplantation fate of cellular therapeutics is poorly understood in both large animal models and in human studies because of limitations in cell graft detection. A minimally invasive technology for cellular graft tracking to visualize grafts in vivo is needed. However, it is important that the diagnostic marker does not impact the engraftment or efficacy of transplanted cells. We developed a straightforward, rapidly translatable method to label human neural progenitor/stem cells with magnetic ferumoxytol nanoparticles. We investigated the potential effect of ferumoxytol labeling on biological properties of the cells and transplanted them into a large animal (porcine) spinal cord. We assessed the feasibility and safety of in vivo diagnostic cell graft tracking using Magnetic Resonance Imaging and post-mortem histological identification in a clinically relevant model. Furthermore, we leveraged this tracking approach to develop and assess a minimally invasive, Magnetic Resonance Imaging-guided technique for targeted intraspinal stem cell graft transplantation in a large animal model.","abstract_has_math":false,"creators":["Lamanna, Jason J."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Boulis, Nicholas M.","Oshinski, John N."],"committee_chairs":[],"committee_members":["Hochman, Shawn","Keilholz, Shella","Galipeau, Jacques"],"year":2015,"date_issued":"2015-07-22","date_published":"2015-07-22","updated_at":"2026-11-19T06:05:38Z","subjects":["Stem cell transplantation","Spinal cord","MRI","Molecular imaging","Interventional MRI","SPIO","Neural stem cell"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/55536","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/55536","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F55536","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Boulis, Nicholas M.","Oshinski, John N."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hochman, Shawn","Keilholz, Shella","Galipeau, Jacques"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Lamanna, Jason J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-08-22T12:20:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-08-22T12:20:59Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-08"]},{"key":"dc:date.issued","label":"Date","values":["2015-07-22"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2015"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2016-08-22T12:20:59Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["05472fe1-6d57-4489-af83-42115a3f55cc"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Stem cell transplantation","Spinal cord","MRI","Molecular imaging","Interventional MRI","SPIO","Neural stem cell"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/55536"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Transplantation of cellular therapeutics into the spinal cord has been explored as treatment for a range of degenerative and traumatic diseases. The post-transplantation fate of cellular therapeutics is poorly understood in both large animal models and in human studies because of limitations in cell graft detection. A minimally invasive technology for cellular graft tracking to visualize grafts in vivo is needed. However, it is important that the diagnostic marker does not impact the engraftment or efficacy of transplanted cells. We developed a straightforward, rapidly translatable method to label human neural progenitor/stem cells with magnetic ferumoxytol nanoparticles. We investigated the potential effect of ferumoxytol labeling on biological properties of the cells and transplanted them into a large animal (porcine) spinal cord. We assessed the feasibility and safety of in vivo diagnostic cell graft tracking using Magnetic Resonance Imaging and post-mortem histological identification in a clinically relevant model. Furthermore, we leveraged this tracking approach to develop and assess a minimally invasive, Magnetic Resonance Imaging-guided technique for targeted intraspinal stem cell graft transplantation in a large animal model."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Magnetic resonance imaging of intraspinal stem cell grafts: Tracking and targeted transplantation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Boulis, Nicholas M.","Oshinski, John N."],"dc:contributor.committeemember":["Hochman, Shawn","Keilholz, Shella","Galipeau, Jacques"],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["Lamanna, Jason J."],"dc:date.accessioned":["2016-08-22T12:20:59Z"],"dc:date.available":["2016-08-22T12:20:59Z"],"dc:date.created":["2015-08"],"dc:date.issued":["2015-07-22"],"dc:date.submitted":["August 2015"],"dc:date.updated":["2016-08-22T12:20:59Z"],"dc:description.abstract":["Transplantation of cellular therapeutics into the spinal cord has been explored as treatment for a range of degenerative and traumatic diseases. The post-transplantation fate of cellular therapeutics is poorly understood in both large animal models and in human studies because of limitations in cell graft detection. A minimally invasive technology for cellular graft tracking to visualize grafts in vivo is needed. However, it is important that the diagnostic marker does not impact the engraftment or efficacy of transplanted cells. We developed a straightforward, rapidly translatable method to label human neural progenitor/stem cells with magnetic ferumoxytol nanoparticles. We investigated the potential effect of ferumoxytol labeling on biological properties of the cells and transplanted them into a large animal (porcine) spinal cord. We assessed the feasibility and safety of in vivo diagnostic cell graft tracking using Magnetic Resonance Imaging and post-mortem histological identification in a clinically relevant model. Furthermore, we leveraged this tracking approach to develop and assess a minimally invasive, Magnetic Resonance Imaging-guided technique for targeted intraspinal stem cell graft transplantation in a large animal model."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/55536"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["05472fe1-6d57-4489-af83-42115a3f55cc"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Biomedical Engineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"],"dc:subject":["Stem cell transplantation","Spinal cord","MRI","Molecular imaging","Interventional MRI","SPIO","Neural stem cell"],"dc:title":["Magnetic resonance imaging of intraspinal stem cell grafts: Tracking and targeted transplantation"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T06:05:38Z"}