{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/55570"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/55570","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Improved diret analysis in real time-mass spectrometry sampling for reproducible quantitative analyses","abstract":"Transmission-mode direct analysis in real time (TM-DART) is presented as an alternative sampling strategy to traditional methods of sample introduction for DART MS analysis. A custom-designed sample holder was fabricated to rapidly and reproducibly position insecticide-treated nets normal to the ionizing metastable gas stream, enabling transmission of desorbed analyte ions through the holder cavity and into the MS. Introduction of the sample at this fixed geometry eliminates the need for optimizing sample position and allows spectra based on factors such as metastable gas temperature and flow to be systematically evaluated. The results presented here, supported by computational fluid dynamic simulations, demonstrate the effects of these factors on the resulting mass spectra and the potential of this sampling strategy to be used for qualitative and quantitative analyses. Transmission-mode desorption electrospray ionization (TM-DESI) experiments on similar insecticide-treated nets were performed for comparison purposes.","abstract_html":"Transmission-mode direct analysis in real time (TM-DART) is presented as an alternative sampling strategy to traditional methods of sample introduction for DART MS analysis. A custom-designed sample holder was fabricated to rapidly and reproducibly position insecticide-treated nets normal to the ionizing metastable gas stream, enabling transmission of desorbed analyte ions through the holder cavity and into the MS. Introduction of the sample at this fixed geometry eliminates the need for optimizing sample position and allows spectra based on factors such as metastable gas temperature and flow to be systematically evaluated. The results presented here, supported by computational fluid dynamic simulations, demonstrate the effects of these factors on the resulting mass spectra and the potential of this sampling strategy to be used for qualitative and quantitative analyses. Transmission-mode desorption electrospray ionization (TM-DESI) experiments on similar insecticide-treated nets were performed for comparison purposes.","abstract_has_math":false,"creators":["Perez, Jose Javier"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Chemistry and Biochemistry","school":null,"contributors":[],"advisors":["Fernández, Facundo M."],"committee_chairs":[],"committee_members":["Janata, Jiri","Sullards, Cameron"],"year":2016,"date_issued":"2016-05-10","date_published":"2016-05-10","updated_at":"2026-11-19T05:15:14Z","subjects":["Direct analysis in real time","Desorption electrospray ionization","Mass spectrometry","Ambient ionization","Pyrethroid insecticides","Bednets","Computational fluid dynamics"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/55570","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/55570","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F55570","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fernández, Facundo M."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Janata, Jiri","Sullards, Cameron"]},{"key":"dc:contributor.department","label":"Department","values":["Chemistry and Biochemistry"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Chemistry and Biochemistry","College of Sciences"]},{"key":"dc:creator","label":"Author","values":["Perez, Jose Javier"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-08-22T12:21:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-08-22T12:21:52Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-08"]},{"key":"dc:date.issued","label":"Date","values":["2016-05-10"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2016"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2016-08-22T12:21:52Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["60fbfa01-4d0f-42eb-93b1-7577bf996e40"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Chemistry"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["f1725b93-3ab8-4c47-a4c3-3596c03d6f1e","85042be6-2d68-4e07-b384-e1f908fae48a"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["8954817e-f914-4a18-bccd-8e0ecaf17c10"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Direct analysis in real time","Desorption electrospray ionization","Mass spectrometry","Ambient ionization","Pyrethroid insecticides","Bednets","Computational fluid dynamics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/55570"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Transmission-mode direct analysis in real time (TM-DART) is presented as an alternative sampling strategy to traditional methods of sample introduction for DART MS analysis. A custom-designed sample holder was fabricated to rapidly and reproducibly position insecticide-treated nets normal to the ionizing metastable gas stream, enabling transmission of desorbed analyte ions through the holder cavity and into the MS. Introduction of the sample at this fixed geometry eliminates the need for optimizing sample position and allows spectra based on factors such as metastable gas temperature and flow to be systematically evaluated. The results presented here, supported by computational fluid dynamic simulations, demonstrate the effects of these factors on the resulting mass spectra and the potential of this sampling strategy to be used for qualitative and quantitative analyses. Transmission-mode desorption electrospray ionization (TM-DESI) experiments on similar insecticide-treated nets were performed for comparison purposes."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Improved diret analysis in real time-mass spectrometry sampling for reproducible quantitative analyses"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fernández, Facundo M."],"dc:contributor.committeemember":["Janata, Jiri","Sullards, Cameron"],"dc:contributor.department":["Chemistry and Biochemistry"],"dc:contributor.other":["School of Chemistry and Biochemistry","College of Sciences"],"dc:creator":["Perez, Jose Javier"],"dc:date.accessioned":["2016-08-22T12:21:52Z"],"dc:date.available":["2016-08-22T12:21:52Z"],"dc:date.created":["2016-08"],"dc:date.issued":["2016-05-10"],"dc:date.submitted":["August 2016"],"dc:date.updated":["2016-08-22T12:21:52Z"],"dc:description.abstract":["Transmission-mode direct analysis in real time (TM-DART) is presented as an alternative sampling strategy to traditional methods of sample introduction for DART MS analysis. A custom-designed sample holder was fabricated to rapidly and reproducibly position insecticide-treated nets normal to the ionizing metastable gas stream, enabling transmission of desorbed analyte ions through the holder cavity and into the MS. Introduction of the sample at this fixed geometry eliminates the need for optimizing sample position and allows spectra based on factors such as metastable gas temperature and flow to be systematically evaluated. The results presented here, supported by computational fluid dynamic simulations, demonstrate the effects of these factors on the resulting mass spectra and the potential of this sampling strategy to be used for qualitative and quantitative analyses. Transmission-mode desorption electrospray ionization (TM-DESI) experiments on similar insecticide-treated nets were performed for comparison purposes."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/55570"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["60fbfa01-4d0f-42eb-93b1-7577bf996e40"],"dc:relation.ispartofseries":["Master of Science in Chemistry"],"dc:relation.orgunit":["f1725b93-3ab8-4c47-a4c3-3596c03d6f1e","85042be6-2d68-4e07-b384-e1f908fae48a"],"dc:relation.seriesentity":["8954817e-f914-4a18-bccd-8e0ecaf17c10"],"dc:subject":["Direct analysis in real time","Desorption electrospray ionization","Mass spectrometry","Ambient ionization","Pyrethroid insecticides","Bednets","Computational fluid dynamics"],"dc:title":["Improved diret analysis in real time-mass spectrometry sampling for reproducible quantitative analyses"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:15:14Z"}