{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/56162"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/56162","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Development of a bulk acoustic resonator sensing platform for cancer biomarker detection","abstract":"Cancer is one of the leading causes of death for patients within the United States and throughout the world. When diagnosed in early growth stages, tumors (regions of uncontrolled cell division) can be more effectively treated and patients are more likely to survive. Therefore, the development of screening technology for early detection of cancer is essential to improve patient survival rates and serves as the motivation for this work. The objective of this dissertation is the design and implementation of a sensing platform for the detection of cancer biomarkers within aqueous patient samples. The system’s transducer is based on previously developed zinc oxide (ZnO) bulk acoustic wave (BAW) resonators that are capable of exciting multiple types of acoustic modes. Chapter 1 presents the motivation for this work along with a short review of gravimetric biosensors used in aqueous applications. Chapter 2 focuses on the history, theoretical derivation, and fabrication protocol for the system transducers and array configuration. In Chapter 3, the Universal Serial Bus (USB) is examined as a potential radio frequency bus for device characterization of MEMs devices. Chapter 4 presents the optimization of a module design for isolating the circuitry from the fluidics pathways for sample exposure. Combining the work of the previous chapters, Chapter 5 validates the ability of the designed system to serve as a biosensing platform. Each individual sensor is functionalized with antibodies selectively binding the desired biomarker. Lastly, Chapter 6 demonstrates a protocol for extracting features from raw sensor data to develop classification models. Thus, providing diagnostic information about the sample exposed to the device.","abstract_html":"Cancer is one of the leading causes of death for patients within the United States and throughout the world. When diagnosed in early growth stages, tumors (regions of uncontrolled cell division) can be more effectively treated and patients are more likely to survive. Therefore, the development of screening technology for early detection of cancer is essential to improve patient survival rates and serves as the motivation for this work. The objective of this dissertation is the design and implementation of a sensing platform for the detection of cancer biomarkers within aqueous patient samples. The system’s transducer is based on previously developed zinc oxide (ZnO) bulk acoustic wave (BAW) resonators that are capable of exciting multiple types of acoustic modes. Chapter 1 presents the motivation for this work along with a short review of gravimetric biosensors used in aqueous applications. Chapter 2 focuses on the history, theoretical derivation, and fabrication protocol for the system transducers and array configuration. In Chapter 3, the Universal Serial Bus (USB) is examined as a potential radio frequency bus for device characterization of MEMs devices. Chapter 4 presents the optimization of a module design for isolating the circuitry from the fluidics pathways for sample exposure. Combining the work of the previous chapters, Chapter 5 validates the ability of the designed system to serve as a biosensing platform. Each individual sensor is functionalized with antibodies selectively binding the desired biomarker. Lastly, Chapter 6 demonstrates a protocol for extracting features from raw sensor data to develop classification models. Thus, providing diagnostic information about the sample exposed to the device.","abstract_has_math":false,"creators":["Mobley, Stephen J."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Bhatti, Pamela T."],"committee_chairs":[],"committee_members":["Hunt, William D.","Brand, Oliver","Doetsch, Paul","Kenney, James S."],"year":2015,"date_issued":"2015-08-11","date_published":"2015-08-11","updated_at":"2026-11-19T06:10:24Z","subjects":["Surface mount resonator","Cancer biomarker","Zinc oxide","Bulk acoustic wave"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/56162","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/56162","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F56162","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bhatti, Pamela T."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hunt, William D.","Brand, Oliver","Doetsch, Paul","Kenney, James S."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Mobley, Stephen J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-01-11T13:56:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-01-11T13:56:31Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-12"]},{"key":"dc:date.issued","label":"Date","values":["2015-08-11"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2015"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2017-01-11T13:56:31Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["de58a4f5-0f0d-4a2c-91f6-bae53faf8e56"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Surface mount resonator","Cancer biomarker","Zinc oxide","Bulk acoustic wave"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/56162"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cancer is one of the leading causes of death for patients within the United States and throughout the world. When diagnosed in early growth stages, tumors (regions of uncontrolled cell division) can be more effectively treated and patients are more likely to survive. Therefore, the development of screening technology for early detection of cancer is essential to improve patient survival rates and serves as the motivation for this work. The objective of this dissertation is the design and implementation of a sensing platform for the detection of cancer biomarkers within aqueous patient samples. The system’s transducer is based on previously developed zinc oxide (ZnO) bulk acoustic wave (BAW) resonators that are capable of exciting multiple types of acoustic modes. Chapter 1 presents the motivation for this work along with a short review of gravimetric biosensors used in aqueous applications. Chapter 2 focuses on the history, theoretical derivation, and fabrication protocol for the system transducers and array configuration. In Chapter 3, the Universal Serial Bus (USB) is examined as a potential radio frequency bus for device characterization of MEMs devices. Chapter 4 presents the optimization of a module design for isolating the circuitry from the fluidics pathways for sample exposure. Combining the work of the previous chapters, Chapter 5 validates the ability of the designed system to serve as a biosensing platform. Each individual sensor is functionalized with antibodies selectively binding the desired biomarker. Lastly, Chapter 6 demonstrates a protocol for extracting features from raw sensor data to develop classification models. Thus, providing diagnostic information about the sample exposed to the device."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of a bulk acoustic resonator sensing platform for cancer biomarker detection"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bhatti, Pamela T."],"dc:contributor.committeemember":["Hunt, William D.","Brand, Oliver","Doetsch, Paul","Kenney, James S."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Mobley, Stephen J."],"dc:date.accessioned":["2017-01-11T13:56:31Z"],"dc:date.available":["2017-01-11T13:56:31Z"],"dc:date.created":["2015-12"],"dc:date.issued":["2015-08-11"],"dc:date.submitted":["December 2015"],"dc:date.updated":["2017-01-11T13:56:31Z"],"dc:description.abstract":["Cancer is one of the leading causes of death for patients within the United States and throughout the world. When diagnosed in early growth stages, tumors (regions of uncontrolled cell division) can be more effectively treated and patients are more likely to survive. Therefore, the development of screening technology for early detection of cancer is essential to improve patient survival rates and serves as the motivation for this work. The objective of this dissertation is the design and implementation of a sensing platform for the detection of cancer biomarkers within aqueous patient samples. The system’s transducer is based on previously developed zinc oxide (ZnO) bulk acoustic wave (BAW) resonators that are capable of exciting multiple types of acoustic modes. Chapter 1 presents the motivation for this work along with a short review of gravimetric biosensors used in aqueous applications. Chapter 2 focuses on the history, theoretical derivation, and fabrication protocol for the system transducers and array configuration. In Chapter 3, the Universal Serial Bus (USB) is examined as a potential radio frequency bus for device characterization of MEMs devices. Chapter 4 presents the optimization of a module design for isolating the circuitry from the fluidics pathways for sample exposure. Combining the work of the previous chapters, Chapter 5 validates the ability of the designed system to serve as a biosensing platform. Each individual sensor is functionalized with antibodies selectively binding the desired biomarker. Lastly, Chapter 6 demonstrates a protocol for extracting features from raw sensor data to develop classification models. Thus, providing diagnostic information about the sample exposed to the device."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/56162"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["de58a4f5-0f0d-4a2c-91f6-bae53faf8e56"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Surface mount resonator","Cancer biomarker","Zinc oxide","Bulk acoustic wave"],"dc:title":["Development of a bulk acoustic resonator sensing platform for cancer biomarker detection"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T06:10:24Z"}