{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/56212"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/56212","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Development of a combined angiography and late gadolinium enhancement MR sequence","abstract":"With the rapid growth of catheter-based interventional cardiology procedures, knowledge of the vasculature surrounding the heart relative to the distribution of scar tissue can provide important information for procedural planning and appropriate patient selection. We developed an MR sequence that would acquire inherently co-registered angiography and scar images by Sharing K-space (SharK) and created image processing methods for a combined display. The SharK sequence was validated by comparing its performance against its respective gold standards for angiographic and scar imaging. The SharK sequence was applied in patients with previous myocardial infarction to create a combined coronary vein and scar display that could be used for pre-procedural planning in patients undergoing Cardiac Resynchronization Therapy. The SharK sequence was also applied in patients post-Pulmonary Vein Isolation to quantify the amount of scar encircling the pulmonary veins by developing a pulmonary vein bullseye. The pulmonary vein bullseyes can be used to improve the ablation process or guide repeat ablations.","abstract_html":"With the rapid growth of catheter-based interventional cardiology procedures, knowledge of the vasculature surrounding the heart relative to the distribution of scar tissue can provide important information for procedural planning and appropriate patient selection. We developed an MR sequence that would acquire inherently co-registered angiography and scar images by Sharing K-space (SharK) and created image processing methods for a combined display. The SharK sequence was validated by comparing its performance against its respective gold standards for angiographic and scar imaging. The SharK sequence was applied in patients with previous myocardial infarction to create a combined coronary vein and scar display that could be used for pre-procedural planning in patients undergoing Cardiac Resynchronization Therapy. The SharK sequence was also applied in patients post-Pulmonary Vein Isolation to quantify the amount of scar encircling the pulmonary veins by developing a pulmonary vein bullseye. The pulmonary vein bullseyes can be used to improve the ablation process or guide repeat ablations.","abstract_has_math":false,"creators":["Lam, Adrian"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Oshinski, John N."],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-11-13","date_published":"2015-11-13","updated_at":"2026-11-19T05:52:19Z","subjects":["Magnetic resonance imaging","Cardiac resynchronization therapy","Atrial fibrillation","Pulmonary vein isolation","Electrophysiology","Image processing"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/56212","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/56212","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F56212","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Oshinski, John N."]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Lam, Adrian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-01-11T14:00:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-01-11T14:00:30Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-12"]},{"key":"dc:date.issued","label":"Date","values":["2015-11-13"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2015"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2017-01-11T14:00:30Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["05472fe1-6d57-4489-af83-42115a3f55cc"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Magnetic resonance imaging","Cardiac resynchronization therapy","Atrial fibrillation","Pulmonary vein isolation","Electrophysiology","Image processing"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/56212"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["With the rapid growth of catheter-based interventional cardiology procedures, knowledge of the vasculature surrounding the heart relative to the distribution of scar tissue can provide important information for procedural planning and appropriate patient selection. We developed an MR sequence that would acquire inherently co-registered angiography and scar images by Sharing K-space (SharK) and created image processing methods for a combined display. The SharK sequence was validated by comparing its performance against its respective gold standards for angiographic and scar imaging. The SharK sequence was applied in patients with previous myocardial infarction to create a combined coronary vein and scar display that could be used for pre-procedural planning in patients undergoing Cardiac Resynchronization Therapy. The SharK sequence was also applied in patients post-Pulmonary Vein Isolation to quantify the amount of scar encircling the pulmonary veins by developing a pulmonary vein bullseye. The pulmonary vein bullseyes can be used to improve the ablation process or guide repeat ablations."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of a combined angiography and late gadolinium enhancement MR sequence"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Oshinski, John N."],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["Lam, Adrian"],"dc:date.accessioned":["2017-01-11T14:00:30Z"],"dc:date.available":["2017-01-11T14:00:30Z"],"dc:date.created":["2015-12"],"dc:date.issued":["2015-11-13"],"dc:date.submitted":["December 2015"],"dc:date.updated":["2017-01-11T14:00:30Z"],"dc:description.abstract":["With the rapid growth of catheter-based interventional cardiology procedures, knowledge of the vasculature surrounding the heart relative to the distribution of scar tissue can provide important information for procedural planning and appropriate patient selection. We developed an MR sequence that would acquire inherently co-registered angiography and scar images by Sharing K-space (SharK) and created image processing methods for a combined display. The SharK sequence was validated by comparing its performance against its respective gold standards for angiographic and scar imaging. The SharK sequence was applied in patients with previous myocardial infarction to create a combined coronary vein and scar display that could be used for pre-procedural planning in patients undergoing Cardiac Resynchronization Therapy. The SharK sequence was also applied in patients post-Pulmonary Vein Isolation to quantify the amount of scar encircling the pulmonary veins by developing a pulmonary vein bullseye. The pulmonary vein bullseyes can be used to improve the ablation process or guide repeat ablations."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/56212"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["05472fe1-6d57-4489-af83-42115a3f55cc"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Biomedical Engineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"],"dc:subject":["Magnetic resonance imaging","Cardiac resynchronization therapy","Atrial fibrillation","Pulmonary vein isolation","Electrophysiology","Image processing"],"dc:title":["Development of a combined angiography and late gadolinium enhancement MR sequence"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:52:19Z"}