{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/58132"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/58132","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Troubleshooting ultrashort pulse measurement: the coherent artifact and other issues","abstract":"Theoretical limitations of several ultrashort pulse measurement techniques are investigated. Particular attention is paid to the consequences of averaging over many pulses of different shapes. Averaging over many pulses is a very common practice, and if the pulse shape varies then the measurement result will be incorrect. This issue, referred to as a coherent artifact, is simulated for frequency-resolved optical gating using several nonlinearities, spectral interferometry for direct electric field reconstruction, two-dimensional spectral shearing interferometry, self-referenced spectral interferometry using cross-polarized wave generation, and multiphoton intrapulse interference phase scan. The role of measurement feedback in identifying pulse-shape instability is explored where possible. Several techniques receive additional analysis, such as searching for ambiguities or simulating convergence conditions. In addition, a method for intuitively displaying spatiotemporally distorted pulses is explored and developed.","abstract_html":"Theoretical limitations of several ultrashort pulse measurement techniques are investigated. Particular attention is paid to the consequences of averaging over many pulses of different shapes. Averaging over many pulses is a very common practice, and if the pulse shape varies then the measurement result will be incorrect. This issue, referred to as a coherent artifact, is simulated for frequency-resolved optical gating using several nonlinearities, spectral interferometry for direct electric field reconstruction, two-dimensional spectral shearing interferometry, self-referenced spectral interferometry using cross-polarized wave generation, and multiphoton intrapulse interference phase scan. The role of measurement feedback in identifying pulse-shape instability is explored where possible. Several techniques receive additional analysis, such as searching for ambiguities or simulating convergence conditions. In addition, a method for intuitively displaying spatiotemporally distorted pulses is explored and developed.","abstract_has_math":false,"creators":["Rhodes, Michelle Ann"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Physics","school":null,"contributors":[],"advisors":["Trebino, Rick"],"committee_chairs":[],"committee_members":["Curtis, Jennifer","Uzer, Turgay","Raman, Chandra","Perry, Joseph"],"year":2016,"date_issued":"2016-03-14","date_published":"2016-03-14","updated_at":"2026-11-19T05:53:49Z","subjects":["Ultrafast optics","Ultrashort pulse measurement"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/58132","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/58132","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F58132","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Trebino, Rick"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Curtis, Jennifer","Uzer, Turgay","Raman, Chandra","Perry, Joseph"]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Sciences","School of Physics"]},{"key":"dc:creator","label":"Author","values":["Rhodes, Michelle Ann"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-06-07T17:32:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-06-07T17:32:36Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-05"]},{"key":"dc:date.issued","label":"Date","values":["2016-03-14"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2016"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2017-06-07T17:32:36Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["40e4f324-6c45-4fe1-ac68-68c3ea37970f"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Physics"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["85042be6-2d68-4e07-b384-e1f908fae48a","2ba39017-11f1-40f4-9bc5-66f17b8f1539"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c1062152-d026-4fb3-84db-ceedbfbbbf56"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ultrafast optics","Ultrashort pulse measurement"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/58132"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Theoretical limitations of several ultrashort pulse measurement techniques are investigated. Particular attention is paid to the consequences of averaging over many pulses of different shapes. Averaging over many pulses is a very common practice, and if the pulse shape varies then the measurement result will be incorrect. This issue, referred to as a coherent artifact, is simulated for frequency-resolved optical gating using several nonlinearities, spectral interferometry for direct electric field reconstruction, two-dimensional spectral shearing interferometry, self-referenced spectral interferometry using cross-polarized wave generation, and multiphoton intrapulse interference phase scan. The role of measurement feedback in identifying pulse-shape instability is explored where possible. Several techniques receive additional analysis, such as searching for ambiguities or simulating convergence conditions. In addition, a method for intuitively displaying spatiotemporally distorted pulses is explored and developed."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Troubleshooting ultrashort pulse measurement: the coherent artifact and other issues"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Trebino, Rick"],"dc:contributor.committeemember":["Curtis, Jennifer","Uzer, Turgay","Raman, Chandra","Perry, Joseph"],"dc:contributor.department":["Physics"],"dc:contributor.other":["College of Sciences","School of Physics"],"dc:creator":["Rhodes, Michelle Ann"],"dc:date.accessioned":["2017-06-07T17:32:36Z"],"dc:date.available":["2017-06-07T17:32:36Z"],"dc:date.created":["2016-05"],"dc:date.issued":["2016-03-14"],"dc:date.submitted":["May 2016"],"dc:date.updated":["2017-06-07T17:32:36Z"],"dc:description.abstract":["Theoretical limitations of several ultrashort pulse measurement techniques are investigated. Particular attention is paid to the consequences of averaging over many pulses of different shapes. Averaging over many pulses is a very common practice, and if the pulse shape varies then the measurement result will be incorrect. This issue, referred to as a coherent artifact, is simulated for frequency-resolved optical gating using several nonlinearities, spectral interferometry for direct electric field reconstruction, two-dimensional spectral shearing interferometry, self-referenced spectral interferometry using cross-polarized wave generation, and multiphoton intrapulse interference phase scan. The role of measurement feedback in identifying pulse-shape instability is explored where possible. Several techniques receive additional analysis, such as searching for ambiguities or simulating convergence conditions. In addition, a method for intuitively displaying spatiotemporally distorted pulses is explored and developed."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/58132"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["40e4f324-6c45-4fe1-ac68-68c3ea37970f"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Physics"],"dc:relation.orgunit":["85042be6-2d68-4e07-b384-e1f908fae48a","2ba39017-11f1-40f4-9bc5-66f17b8f1539"],"dc:relation.seriesentity":["c1062152-d026-4fb3-84db-ceedbfbbbf56"],"dc:subject":["Ultrafast optics","Ultrashort pulse measurement"],"dc:title":["Troubleshooting ultrashort pulse measurement: the coherent artifact and other issues"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:53:49Z"}