{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/58601"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/58601","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Computational optimization of transcatheter aortic valve leaflet design","abstract":"Transcatheter aortic valve (TAV) replacement is now the standard of care treatment for aortic stenosis in high-risk patients. There has been a recent push in the industry to develop smaller profile TAVs to make this treatment a safe and effective alternative to valve surgery in an even wider spectrum of patients. Smaller devices requiring thinner leaflets may come with the tradeoff of reduced durability. However, the impacts of different TAV leaflet materials and valve designs on TAV function and durability, particularly under non-ideal deployment conditions, have not been thoroughly assessed. By combining material modeling and geometric parameterization of valve leaflets, performance and safety of TAV devices can be comprehensively evaluated. The objectives of this study were to employ constitutive modeling tools to describe the material properties of pericardial tissues, and then to implement them in the development of a computational framework for exploring the impacts of leaflet material and design on TAV function. The mechanical properties of pericardial tissue have not been well characterized, particularly under flexure, which is an important mode of deformation for native and bioprosthetic heart valves. Pericardia material models were implemented in finite element simulations of valve deformation and directly compared. The impact of TAV leaflet material and geometry on mechanical stress was closely examined and fundamental relationships between design characteristics and leaflet deformation were established. Eccentric TAV expansion was modeled and optimization tools were employed to identify leaflet geometries which minimize stress during mechanical loading to increase durability. The results from these studies may offer scientific rationale for the design of durable and robust next-generation TAV devices.","abstract_html":"Transcatheter aortic valve (TAV) replacement is now the standard of care treatment for aortic stenosis in high-risk patients. There has been a recent push in the industry to develop smaller profile TAVs to make this treatment a safe and effective alternative to valve surgery in an even wider spectrum of patients. Smaller devices requiring thinner leaflets may come with the tradeoff of reduced durability. However, the impacts of different TAV leaflet materials and valve designs on TAV function and durability, particularly under non-ideal deployment conditions, have not been thoroughly assessed. By combining material modeling and geometric parameterization of valve leaflets, performance and safety of TAV devices can be comprehensively evaluated. The objectives of this study were to employ constitutive modeling tools to describe the material properties of pericardial tissues, and then to implement them in the development of a computational framework for exploring the impacts of leaflet material and design on TAV function. The mechanical properties of pericardial tissue have not been well characterized, particularly under flexure, which is an important mode of deformation for native and bioprosthetic heart valves. Pericardia material models were implemented in finite element simulations of valve deformation and directly compared. The impact of TAV leaflet material and geometry on mechanical stress was closely examined and fundamental relationships between design characteristics and leaflet deformation were established. Eccentric TAV expansion was modeled and optimization tools were employed to identify leaflet geometries which minimize stress during mechanical loading to increase durability. The results from these studies may offer scientific rationale for the design of durable and robust next-generation TAV devices.","abstract_has_math":false,"creators":["Murdock, Kyle"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Sun, Wei"],"committee_chairs":[],"committee_members":["Wang, Yan","Padala, Muralidhar","Sarin, Eric"],"year":2016,"date_issued":"2016-07-21","date_published":"2016-07-21","updated_at":"2026-11-19T05:17:26Z","subjects":["Transcatheter aortic valve","Geometric optimization"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/58601","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/58601","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F58601","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sun, Wei"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wang, Yan","Padala, Muralidhar","Sarin, Eric"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Murdock, Kyle"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-08-17T18:57:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-08-17T18:57:23Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-08"]},{"key":"dc:date.issued","label":"Date","values":["2016-07-21"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2016"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2017-08-17T18:57:23Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Transcatheter aortic valve","Geometric optimization"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/58601"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Transcatheter aortic valve (TAV) replacement is now the standard of care treatment for aortic stenosis in high-risk patients. There has been a recent push in the industry to develop smaller profile TAVs to make this treatment a safe and effective alternative to valve surgery in an even wider spectrum of patients. Smaller devices requiring thinner leaflets may come with the tradeoff of reduced durability. However, the impacts of different TAV leaflet materials and valve designs on TAV function and durability, particularly under non-ideal deployment conditions, have not been thoroughly assessed. By combining material modeling and geometric parameterization of valve leaflets, performance and safety of TAV devices can be comprehensively evaluated. The objectives of this study were to employ constitutive modeling tools to describe the material properties of pericardial tissues, and then to implement them in the development of a computational framework for exploring the impacts of leaflet material and design on TAV function. The mechanical properties of pericardial tissue have not been well characterized, particularly under flexure, which is an important mode of deformation for native and bioprosthetic heart valves. Pericardia material models were implemented in finite element simulations of valve deformation and directly compared. The impact of TAV leaflet material and geometry on mechanical stress was closely examined and fundamental relationships between design characteristics and leaflet deformation were established. Eccentric TAV expansion was modeled and optimization tools were employed to identify leaflet geometries which minimize stress during mechanical loading to increase durability. The results from these studies may offer scientific rationale for the design of durable and robust next-generation TAV devices."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Computational optimization of transcatheter aortic valve leaflet design"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sun, Wei"],"dc:contributor.committeemember":["Wang, Yan","Padala, Muralidhar","Sarin, Eric"],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["Murdock, Kyle"],"dc:date.accessioned":["2017-08-17T18:57:23Z"],"dc:date.available":["2017-08-17T18:57:23Z"],"dc:date.created":["2016-08"],"dc:date.issued":["2016-07-21"],"dc:date.submitted":["August 2016"],"dc:date.updated":["2017-08-17T18:57:23Z"],"dc:description.abstract":["Transcatheter aortic valve (TAV) replacement is now the standard of care treatment for aortic stenosis in high-risk patients. There has been a recent push in the industry to develop smaller profile TAVs to make this treatment a safe and effective alternative to valve surgery in an even wider spectrum of patients. Smaller devices requiring thinner leaflets may come with the tradeoff of reduced durability. However, the impacts of different TAV leaflet materials and valve designs on TAV function and durability, particularly under non-ideal deployment conditions, have not been thoroughly assessed. By combining material modeling and geometric parameterization of valve leaflets, performance and safety of TAV devices can be comprehensively evaluated. The objectives of this study were to employ constitutive modeling tools to describe the material properties of pericardial tissues, and then to implement them in the development of a computational framework for exploring the impacts of leaflet material and design on TAV function. The mechanical properties of pericardial tissue have not been well characterized, particularly under flexure, which is an important mode of deformation for native and bioprosthetic heart valves. Pericardia material models were implemented in finite element simulations of valve deformation and directly compared. The impact of TAV leaflet material and geometry on mechanical stress was closely examined and fundamental relationships between design characteristics and leaflet deformation were established. Eccentric TAV expansion was modeled and optimization tools were employed to identify leaflet geometries which minimize stress during mechanical loading to increase durability. The results from these studies may offer scientific rationale for the design of durable and robust next-generation TAV devices."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/58601"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Master of Science in Biomedical Engineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"],"dc:subject":["Transcatheter aortic valve","Geometric optimization"],"dc:title":["Computational optimization of transcatheter aortic valve leaflet design"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:17:26Z"}