{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/58634"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/58634","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Novel methods for iterative reconstruction and noise estimation in CT imaging","abstract":"Computed tomography (CT) has become an important clinical imaging modality, and has been extended into a wide range of usage with the development of novel CT scanners such as dual energy CT (DECT). However, the imaging dose during CT scanning increasingly raises public concern. Iterative reconstruction algorithms have shown promise on improving quality of CT images with reduced radiation. In the first part of this study, a novel iterative reconstruction method is developed to enable a new data acquisition scheme for potential reduction in imaging dose and engineering cost of DECT. As iterative CT reconstruction continues to advance, the spatial distribution of noise standard deviation (STD) and accurate noise power spectrum (NPS) on the reconstructed CT images become important for method evaluation as well as optimization of algorithm parameters. In the second part of this study, a practical method for pixel-wise calculation of noise statistics on an iteratively reconstructed CT image is developed, which enables accurate calculation of noise STD for each pixel and NPS.","abstract_html":"Computed tomography (CT) has become an important clinical imaging modality, and has been extended into a wide range of usage with the development of novel CT scanners such as dual energy CT (DECT). However, the imaging dose during CT scanning increasingly raises public concern. Iterative reconstruction algorithms have shown promise on improving quality of CT images with reduced radiation. In the first part of this study, a novel iterative reconstruction method is developed to enable a new data acquisition scheme for potential reduction in imaging dose and engineering cost of DECT. As iterative CT reconstruction continues to advance, the spatial distribution of noise standard deviation (STD) and accurate noise power spectrum (NPS) on the reconstructed CT images become important for method evaluation as well as optimization of algorithm parameters. In the second part of this study, a practical method for pixel-wise calculation of noise statistics on an iteratively reconstructed CT image is developed, which enables accurate calculation of noise STD for each pixel and NPS.","abstract_has_math":false,"creators":["Wang, Tonghe"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Zhu, Lei"],"committee_chairs":[],"committee_members":["Wang, C.-K. Chris","Tang, Xiangyang","Roper, Justin","Aarsvold, John N."],"year":2017,"date_issued":"2017-04-24","date_published":"2017-04-24","updated_at":"2026-11-19T05:56:14Z","subjects":["Iterative reconstruction","CT","Noise estimation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/58634","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/58634","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F58634","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhu, Lei"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wang, C.-K. Chris","Tang, Xiangyang","Roper, Justin","Aarsvold, John N."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Wang, Tonghe"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-08-17T18:58:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-08-17T18:58:20Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-08"]},{"key":"dc:date.issued","label":"Date","values":["2017-04-24"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2017"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2017-08-17T18:58:20Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Iterative reconstruction","CT","Noise estimation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/58634"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Computed tomography (CT) has become an important clinical imaging modality, and has been extended into a wide range of usage with the development of novel CT scanners such as dual energy CT (DECT). However, the imaging dose during CT scanning increasingly raises public concern. Iterative reconstruction algorithms have shown promise on improving quality of CT images with reduced radiation. In the first part of this study, a novel iterative reconstruction method is developed to enable a new data acquisition scheme for potential reduction in imaging dose and engineering cost of DECT. As iterative CT reconstruction continues to advance, the spatial distribution of noise standard deviation (STD) and accurate noise power spectrum (NPS) on the reconstructed CT images become important for method evaluation as well as optimization of algorithm parameters. In the second part of this study, a practical method for pixel-wise calculation of noise statistics on an iteratively reconstructed CT image is developed, which enables accurate calculation of noise STD for each pixel and NPS."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Novel methods for iterative reconstruction and noise estimation in CT imaging"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zhu, Lei"],"dc:contributor.committeemember":["Wang, C.-K. Chris","Tang, Xiangyang","Roper, Justin","Aarsvold, John N."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Wang, Tonghe"],"dc:date.accessioned":["2017-08-17T18:58:20Z"],"dc:date.available":["2017-08-17T18:58:20Z"],"dc:date.created":["2017-08"],"dc:date.issued":["2017-04-24"],"dc:date.submitted":["August 2017"],"dc:date.updated":["2017-08-17T18:58:20Z"],"dc:description.abstract":["Computed tomography (CT) has become an important clinical imaging modality, and has been extended into a wide range of usage with the development of novel CT scanners such as dual energy CT (DECT). However, the imaging dose during CT scanning increasingly raises public concern. Iterative reconstruction algorithms have shown promise on improving quality of CT images with reduced radiation. In the first part of this study, a novel iterative reconstruction method is developed to enable a new data acquisition scheme for potential reduction in imaging dose and engineering cost of DECT. As iterative CT reconstruction continues to advance, the spatial distribution of noise standard deviation (STD) and accurate noise power spectrum (NPS) on the reconstructed CT images become important for method evaluation as well as optimization of algorithm parameters. In the second part of this study, a practical method for pixel-wise calculation of noise statistics on an iteratively reconstructed CT image is developed, which enables accurate calculation of noise STD for each pixel and NPS."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/58634"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Iterative reconstruction","CT","Noise estimation"],"dc:title":["Novel methods for iterative reconstruction and noise estimation in CT imaging"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:56:14Z"}