{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/58687"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/58687","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Investigation of fluid dynamic effects of endovascular intervention in a model of descending aortic dissection","abstract":"With advances in endovascular technology and technique, Thoracic EndoVascular Aortic Repair (TEVAR) has emerged as an integral component of the management of Stanford Type B dissection of the descending aorta. Whereas this modality is considered vital in the treatment of patients experiencing severe complications as a result of dissection, it has not been shown to be demonstratively superior to treatment with medical therapy alone in the absence of malperfusion, rupture, or aneurysmal degeneration. However, results from various clinical studies on the relative benefits of these therapies may be confounded by the vast heterogeneity in dissection anatomy and hemodynamics. Therefore, little is known regarding which patients should undergo TEVAR, as well as the effect of stent-graft deployment on the functional status of the aorta. In order to address this knowledge gap, compliant models of the aorta possessing a mobile intimal flap mimicking dissection were fabricated and imaged via four-dimensional phase contrast magnetic resonance (4D PCMR) imaging sensitive to fluid flow. We aimed to understand how the fluid flow varies with changes to the dissection anatomy as well as the effect of varying anatomies on the fluid shear rate, which has been related to the thrombotic potential of blood-contacting surfaces. Furthermore, we aimed to study the effects of graft deployment on these hemodynamic effects. Dissection induced flow reversal in the aorta, with concomitant low and oscillatory shear zones, which were reduced in dissections with multiple tears. Device deployment was found to restore normal hemodynamics locally, while preserving distal hemodynamic alterations. These findings suggest a potential for risk-stratification based on anatomical and functional imaging as well as more aggressive intervention to rectify aberrant fluid mechanics of the dissected aorta.","abstract_html":"With advances in endovascular technology and technique, Thoracic EndoVascular Aortic Repair (TEVAR) has emerged as an integral component of the management of Stanford Type B dissection of the descending aorta. Whereas this modality is considered vital in the treatment of patients experiencing severe complications as a result of dissection, it has not been shown to be demonstratively superior to treatment with medical therapy alone in the absence of malperfusion, rupture, or aneurysmal degeneration. However, results from various clinical studies on the relative benefits of these therapies may be confounded by the vast heterogeneity in dissection anatomy and hemodynamics. Therefore, little is known regarding which patients should undergo TEVAR, as well as the effect of stent-graft deployment on the functional status of the aorta. In order to address this knowledge gap, compliant models of the aorta possessing a mobile intimal flap mimicking dissection were fabricated and imaged via four-dimensional phase contrast magnetic resonance (4D PCMR) imaging sensitive to fluid flow. We aimed to understand how the fluid flow varies with changes to the dissection anatomy as well as the effect of varying anatomies on the fluid shear rate, which has been related to the thrombotic potential of blood-contacting surfaces. Furthermore, we aimed to study the effects of graft deployment on these hemodynamic effects. Dissection induced flow reversal in the aorta, with concomitant low and oscillatory shear zones, which were reduced in dissections with multiple tears. Device deployment was found to restore normal hemodynamics locally, while preserving distal hemodynamic alterations. These findings suggest a potential for risk-stratification based on anatomical and functional imaging as well as more aggressive intervention to rectify aberrant fluid mechanics of the dissected aorta.","abstract_has_math":false,"creators":["Birjiniuk, Joav"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Oshinski, John N.","Ku, David N."],"committee_chairs":[],"committee_members":["Veeraswamy, Ravi K","Taylor, W. Robert","Sun, Wei","Dixon, J. B"],"year":2017,"date_issued":"2017-07-24","date_published":"2017-07-24","updated_at":"2026-11-19T06:03:21Z","subjects":["aortic dissection, fluid mechanics, hemodynamics, experimental model"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/58687","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/58687","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F58687","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Oshinski, John N.","Ku, David N."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Veeraswamy, Ravi K","Taylor, W. Robert","Sun, Wei","Dixon, J. B"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Birjiniuk, Joav"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-08-17T18:59:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-08-17T18:59:55Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-08"]},{"key":"dc:date.issued","label":"Date","values":["2017-07-24"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2017"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2017-08-17T18:59:55Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["05472fe1-6d57-4489-af83-42115a3f55cc","fcccb519-e993-4e74-80be-d919b82c6af4"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["aortic dissection, fluid mechanics, hemodynamics, experimental model"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/58687"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["With advances in endovascular technology and technique, Thoracic EndoVascular Aortic Repair (TEVAR) has emerged as an integral component of the management of Stanford Type B dissection of the descending aorta. Whereas this modality is considered vital in the treatment of patients experiencing severe complications as a result of dissection, it has not been shown to be demonstratively superior to treatment with medical therapy alone in the absence of malperfusion, rupture, or aneurysmal degeneration. However, results from various clinical studies on the relative benefits of these therapies may be confounded by the vast heterogeneity in dissection anatomy and hemodynamics. Therefore, little is known regarding which patients should undergo TEVAR, as well as the effect of stent-graft deployment on the functional status of the aorta. In order to address this knowledge gap, compliant models of the aorta possessing a mobile intimal flap mimicking dissection were fabricated and imaged via four-dimensional phase contrast magnetic resonance (4D PCMR) imaging sensitive to fluid flow. We aimed to understand how the fluid flow varies with changes to the dissection anatomy as well as the effect of varying anatomies on the fluid shear rate, which has been related to the thrombotic potential of blood-contacting surfaces. Furthermore, we aimed to study the effects of graft deployment on these hemodynamic effects. Dissection induced flow reversal in the aorta, with concomitant low and oscillatory shear zones, which were reduced in dissections with multiple tears. Device deployment was found to restore normal hemodynamics locally, while preserving distal hemodynamic alterations. These findings suggest a potential for risk-stratification based on anatomical and functional imaging as well as more aggressive intervention to rectify aberrant fluid mechanics of the dissected aorta."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Investigation of fluid dynamic effects of endovascular intervention in a model of descending aortic dissection"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Oshinski, John N.","Ku, David N."],"dc:contributor.committeemember":["Veeraswamy, Ravi K","Taylor, W. Robert","Sun, Wei","Dixon, J. B"],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["Birjiniuk, Joav"],"dc:date.accessioned":["2017-08-17T18:59:55Z"],"dc:date.available":["2017-08-17T18:59:55Z"],"dc:date.created":["2017-08"],"dc:date.issued":["2017-07-24"],"dc:date.submitted":["August 2017"],"dc:date.updated":["2017-08-17T18:59:55Z"],"dc:description.abstract":["With advances in endovascular technology and technique, Thoracic EndoVascular Aortic Repair (TEVAR) has emerged as an integral component of the management of Stanford Type B dissection of the descending aorta. Whereas this modality is considered vital in the treatment of patients experiencing severe complications as a result of dissection, it has not been shown to be demonstratively superior to treatment with medical therapy alone in the absence of malperfusion, rupture, or aneurysmal degeneration. However, results from various clinical studies on the relative benefits of these therapies may be confounded by the vast heterogeneity in dissection anatomy and hemodynamics. Therefore, little is known regarding which patients should undergo TEVAR, as well as the effect of stent-graft deployment on the functional status of the aorta. In order to address this knowledge gap, compliant models of the aorta possessing a mobile intimal flap mimicking dissection were fabricated and imaged via four-dimensional phase contrast magnetic resonance (4D PCMR) imaging sensitive to fluid flow. We aimed to understand how the fluid flow varies with changes to the dissection anatomy as well as the effect of varying anatomies on the fluid shear rate, which has been related to the thrombotic potential of blood-contacting surfaces. Furthermore, we aimed to study the effects of graft deployment on these hemodynamic effects. Dissection induced flow reversal in the aorta, with concomitant low and oscillatory shear zones, which were reduced in dissections with multiple tears. Device deployment was found to restore normal hemodynamics locally, while preserving distal hemodynamic alterations. These findings suggest a potential for risk-stratification based on anatomical and functional imaging as well as more aggressive intervention to rectify aberrant fluid mechanics of the dissected aorta."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/58687"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["05472fe1-6d57-4489-af83-42115a3f55cc","fcccb519-e993-4e74-80be-d919b82c6af4"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Biomedical Engineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"],"dc:subject":["aortic dissection, fluid mechanics, hemodynamics, experimental model"],"dc:title":["Investigation of fluid dynamic effects of endovascular intervention in a model of descending aortic dissection"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T06:03:21Z"}