{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/59192"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/59192","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Noncontact nonlinear resonance ultrasound spectroscopy for small metallic samples","abstract":"The aim of this research is to evaluate the influence of microscopic material damage to the hysteretic nonlinearity parameter, α. Therefore, this study applies contact and noncontact setup combinations of the nonlinear resonance ultrasound spectroscopy (NRUS) technique to small metallic specimen and analyzes their validity and significance. The various resonance modes of small plates (20mm x 1mm) and slender bars (10mm x 10mm x 100mm) are excited by contact-coupled and noncontact air-coupled piezoelectric transducers and a laser vibrometer detects the out-of-plane velocity of the vibrating specimen surfaces. The amount of the shift of the resonance frequency for increasing excitation levels represents the nonlinear behavior of the material. The experimental setups together with the measuring and data processing protocols are optimized and analyzed for measurement accuracy and system nonlinearity and evaluated with the results of a thermally aged 17-PH stainless steel measurement series. The results show the advantages of noncontact over contact excitation and demonstrate the sensitivity of this NRUS technique to microstructural changes in stainless steel.","abstract_html":"The aim of this research is to evaluate the influence of microscopic material damage to the hysteretic nonlinearity parameter, α. Therefore, this study applies contact and noncontact setup combinations of the nonlinear resonance ultrasound spectroscopy (NRUS) technique to small metallic specimen and analyzes their validity and significance. The various resonance modes of small plates (20mm x 1mm) and slender bars (10mm x 10mm x 100mm) are excited by contact-coupled and noncontact air-coupled piezoelectric transducers and a laser vibrometer detects the out-of-plane velocity of the vibrating specimen surfaces. The amount of the shift of the resonance frequency for increasing excitation levels represents the nonlinear behavior of the material. The experimental setups together with the measuring and data processing protocols are optimized and analyzed for measurement accuracy and system nonlinearity and evaluated with the results of a thermally aged 17-PH stainless steel measurement series. The results show the advantages of noncontact over contact excitation and demonstrate the sensitivity of this NRUS technique to microstructural changes in stainless steel.","abstract_has_math":false,"creators":["Maier, Steffen Georg"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Jacobs, Laurence J."],"committee_chairs":[],"committee_members":["Kim, Jin-Yeon","Qu, Jianmin"],"year":2017,"date_issued":"2017-08-14","date_published":"2017-08-14","updated_at":"2026-11-19T05:13:53Z","subjects":["NRUS, Nonlinear Ultrasound, Nondestructive Evaluation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/59192","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/59192","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F59192","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jacobs, Laurence J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kim, Jin-Yeon","Qu, Jianmin"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Maier, Steffen Georg"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-22T21:08:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-22T21:08:34Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-12"]},{"key":"dc:date.issued","label":"Date","values":["2017-08-14"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2017"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2018-01-22T21:08:34Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["5af40958-ece2-4a76-b071-5ba4c6d99d80"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Engineering Science and Mechanics"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["7a332c00-0af4-4db0-8d23-dbf522cc0e99"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["NRUS, Nonlinear Ultrasound, Nondestructive Evaluation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/59192"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The aim of this research is to evaluate the influence of microscopic material damage to the hysteretic nonlinearity parameter, α. Therefore, this study applies contact and noncontact setup combinations of the nonlinear resonance ultrasound spectroscopy (NRUS) technique to small metallic specimen and analyzes their validity and significance. The various resonance modes of small plates (20mm x 1mm) and slender bars (10mm x 10mm x 100mm) are excited by contact-coupled and noncontact air-coupled piezoelectric transducers and a laser vibrometer detects the out-of-plane velocity of the vibrating specimen surfaces. The amount of the shift of the resonance frequency for increasing excitation levels represents the nonlinear behavior of the material. The experimental setups together with the measuring and data processing protocols are optimized and analyzed for measurement accuracy and system nonlinearity and evaluated with the results of a thermally aged 17-PH stainless steel measurement series. The results show the advantages of noncontact over contact excitation and demonstrate the sensitivity of this NRUS technique to microstructural changes in stainless steel."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Noncontact nonlinear resonance ultrasound spectroscopy for small metallic samples"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jacobs, Laurence J."],"dc:contributor.committeemember":["Kim, Jin-Yeon","Qu, Jianmin"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Maier, Steffen Georg"],"dc:date.accessioned":["2018-01-22T21:08:34Z"],"dc:date.available":["2018-01-22T21:08:34Z"],"dc:date.created":["2017-12"],"dc:date.issued":["2017-08-14"],"dc:date.submitted":["December 2017"],"dc:date.updated":["2018-01-22T21:08:34Z"],"dc:description.abstract":["The aim of this research is to evaluate the influence of microscopic material damage to the hysteretic nonlinearity parameter, α. Therefore, this study applies contact and noncontact setup combinations of the nonlinear resonance ultrasound spectroscopy (NRUS) technique to small metallic specimen and analyzes their validity and significance. The various resonance modes of small plates (20mm x 1mm) and slender bars (10mm x 10mm x 100mm) are excited by contact-coupled and noncontact air-coupled piezoelectric transducers and a laser vibrometer detects the out-of-plane velocity of the vibrating specimen surfaces. The amount of the shift of the resonance frequency for increasing excitation levels represents the nonlinear behavior of the material. The experimental setups together with the measuring and data processing protocols are optimized and analyzed for measurement accuracy and system nonlinearity and evaluated with the results of a thermally aged 17-PH stainless steel measurement series. The results show the advantages of noncontact over contact excitation and demonstrate the sensitivity of this NRUS technique to microstructural changes in stainless steel."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/59192"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["5af40958-ece2-4a76-b071-5ba4c6d99d80"],"dc:relation.ispartofseries":["Master of Science in Engineering Science and Mechanics"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["7a332c00-0af4-4db0-8d23-dbf522cc0e99"],"dc:subject":["NRUS, Nonlinear Ultrasound, Nondestructive Evaluation"],"dc:title":["Noncontact nonlinear resonance ultrasound spectroscopy for small metallic samples"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:13:53Z"}