{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/59193"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/59193","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Nonlinear ultrasonic phased array imaging of partially-closed fatigue cracks","abstract":"Phased array ultrasound is a highly advanced technique that is not only used in the nondestructive evaluation (NDE) of defects in materials but also in the medical diagnostic, for instance, e.g. for a noninvasive examination of the heart. However, difficulties occur in NDE applications when it comes to monitoring some challenging (nonlinear) defects such as small fatigue cracks in the early stages or partially- or fully- closed cracks. Small cracks may be undetected or sizes of closed cracks maybe underestimated. The aim of this research is to obtain images of the closed part of a fatigue crack using the nonlinear ultrasonic phased array method. The present technique is based on a subtraction of response signals received at a sufficiently high and low energy level. In this study, the essential experiments are performed on an aluminum CT specimen of 15 mm thickness that has a fatigue crack of 25 mm length and a Plexiglas specimen of 50 mm thickness. The crack in the Plexiglas specimen was produced by stretching the initial notch width of 2 mm to a final width of 2.5 mm. In order to investigate and evaluate these cracks, a commercial phased array system, with a 16 element probe operating at a frequency of 1.5 MHz, is used. The image of the crack tip is successfully generated by post-processing of the received signals at two excitation levels. The results clearly demonstrate the efficiency of the presented method to detect and image nonlinear defects.","abstract_html":"Phased array ultrasound is a highly advanced technique that is not only used in the nondestructive evaluation (NDE) of defects in materials but also in the medical diagnostic, for instance, e.g. for a noninvasive examination of the heart. However, difficulties occur in NDE applications when it comes to monitoring some challenging (nonlinear) defects such as small fatigue cracks in the early stages or partially- or fully- closed cracks. Small cracks may be undetected or sizes of closed cracks maybe underestimated. The aim of this research is to obtain images of the closed part of a fatigue crack using the nonlinear ultrasonic phased array method. The present technique is based on a subtraction of response signals received at a sufficiently high and low energy level. In this study, the essential experiments are performed on an aluminum CT specimen of 15 mm thickness that has a fatigue crack of 25 mm length and a Plexiglas specimen of 50 mm thickness. The crack in the Plexiglas specimen was produced by stretching the initial notch width of 2 mm to a final width of 2.5 mm. In order to investigate and evaluate these cracks, a commercial phased array system, with a 16 element probe operating at a frequency of 1.5 MHz, is used. The image of the crack tip is successfully generated by post-processing of the received signals at two excitation levels. The results clearly demonstrate the efficiency of the presented method to detect and image nonlinear defects.","abstract_has_math":false,"creators":["Saljanin, Miralem"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Jacobs, Laurence J."],"committee_chairs":[],"committee_members":["Kim, Jin-Yeon","Qu, Jianmin"],"year":2017,"date_issued":"2017-08-14","date_published":"2017-08-14","updated_at":"2026-11-19T05:00:16Z","subjects":["Nonlinear ultrasonic phased array imaging","Partially-closed crack"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/59193","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/59193","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F59193","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jacobs, Laurence J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kim, Jin-Yeon","Qu, Jianmin"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Saljanin, Miralem"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-22T21:08:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-22T21:08:36Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-12"]},{"key":"dc:date.issued","label":"Date","values":["2017-08-14"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2017"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2018-01-22T21:08:36Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["5af40958-ece2-4a76-b071-5ba4c6d99d80"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Engineering Science and Mechanics"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["7a332c00-0af4-4db0-8d23-dbf522cc0e99"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nonlinear ultrasonic phased array imaging","Partially-closed crack"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/59193"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Phased array ultrasound is a highly advanced technique that is not only used in the nondestructive evaluation (NDE) of defects in materials but also in the medical diagnostic, for instance, e.g. for a noninvasive examination of the heart. However, difficulties occur in NDE applications when it comes to monitoring some challenging (nonlinear) defects such as small fatigue cracks in the early stages or partially- or fully- closed cracks. Small cracks may be undetected or sizes of closed cracks maybe underestimated. The aim of this research is to obtain images of the closed part of a fatigue crack using the nonlinear ultrasonic phased array method. The present technique is based on a subtraction of response signals received at a sufficiently high and low energy level. In this study, the essential experiments are performed on an aluminum CT specimen of 15 mm thickness that has a fatigue crack of 25 mm length and a Plexiglas specimen of 50 mm thickness. The crack in the Plexiglas specimen was produced by stretching the initial notch width of 2 mm to a final width of 2.5 mm. In order to investigate and evaluate these cracks, a commercial phased array system, with a 16 element probe operating at a frequency of 1.5 MHz, is used. The image of the crack tip is successfully generated by post-processing of the received signals at two excitation levels. The results clearly demonstrate the efficiency of the presented method to detect and image nonlinear defects."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Nonlinear ultrasonic phased array imaging of partially-closed fatigue cracks"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jacobs, Laurence J."],"dc:contributor.committeemember":["Kim, Jin-Yeon","Qu, Jianmin"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Saljanin, Miralem"],"dc:date.accessioned":["2018-01-22T21:08:36Z"],"dc:date.available":["2018-01-22T21:08:36Z"],"dc:date.created":["2017-12"],"dc:date.issued":["2017-08-14"],"dc:date.submitted":["December 2017"],"dc:date.updated":["2018-01-22T21:08:36Z"],"dc:description.abstract":["Phased array ultrasound is a highly advanced technique that is not only used in the nondestructive evaluation (NDE) of defects in materials but also in the medical diagnostic, for instance, e.g. for a noninvasive examination of the heart. However, difficulties occur in NDE applications when it comes to monitoring some challenging (nonlinear) defects such as small fatigue cracks in the early stages or partially- or fully- closed cracks. Small cracks may be undetected or sizes of closed cracks maybe underestimated. The aim of this research is to obtain images of the closed part of a fatigue crack using the nonlinear ultrasonic phased array method. The present technique is based on a subtraction of response signals received at a sufficiently high and low energy level. In this study, the essential experiments are performed on an aluminum CT specimen of 15 mm thickness that has a fatigue crack of 25 mm length and a Plexiglas specimen of 50 mm thickness. The crack in the Plexiglas specimen was produced by stretching the initial notch width of 2 mm to a final width of 2.5 mm. In order to investigate and evaluate these cracks, a commercial phased array system, with a 16 element probe operating at a frequency of 1.5 MHz, is used. The image of the crack tip is successfully generated by post-processing of the received signals at two excitation levels. The results clearly demonstrate the efficiency of the presented method to detect and image nonlinear defects."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/59193"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["5af40958-ece2-4a76-b071-5ba4c6d99d80"],"dc:relation.ispartofseries":["Master of Science in Engineering Science and Mechanics"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["7a332c00-0af4-4db0-8d23-dbf522cc0e99"],"dc:subject":["Nonlinear ultrasonic phased array imaging","Partially-closed crack"],"dc:title":["Nonlinear ultrasonic phased array imaging of partially-closed fatigue cracks"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:00:16Z"}