{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/59282"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/59282","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Sensitivity analysis and parameterization of passively measured prompt-diagnostic signatures from a nuclear detonation and the effects on early-time attribution","abstract":"An orphaned nuclear detonation in an urban environment would create enormous pressure on policy makers to act quickly requiring strong attribution evidence. To answer these needs, this research examines prompt emissions within 60 seconds after detonation. This time period is defined as peri-detonation nuclear forensics and supports traditional post-detonation nuclear forensics which focus on sample/particulate collection and analysis. The competing physical effects and number of unknowns that affect prompt emissions, global and local sensitivity methods must be employed for determining which device characteristics can be determined at early-times. The results of these sensitivities and trends aid a Monte Carlo Filtering matching algorithm that accurately determines yield, fuel-type, mass, and height-of-burst from hypothetical photon emissions from simplified Fat Man and Little Boy design derivatives. Additionally, signatures emanating from nuclear cloud rise models between approximately 3 and 60 seconds refined the results from the Monte Carlo Filtering algorithm, reducing uncertainty and improving accuracy. Superior Monte Carlo Filtering accuracy and lowered uncertainty indicates promise of using signatures from nuclear cloud rise as diagnostic indicators, if earlier data is destroyed or unavailable. Additionally, experimental photon emission sensitivities were shown with varying masses of Pu-239 within 0.01 seconds using select energy ranges from the 47-group photon energy structure. The derived early signatures may provide policy makers with empirical attribution evidence when combined with intelligence from other collection disciplines.","abstract_html":"An orphaned nuclear detonation in an urban environment would create enormous pressure on policy makers to act quickly requiring strong attribution evidence. To answer these needs, this research examines prompt emissions within 60 seconds after detonation. This time period is defined as peri-detonation nuclear forensics and supports traditional post-detonation nuclear forensics which focus on sample/particulate collection and analysis. The competing physical effects and number of unknowns that affect prompt emissions, global and local sensitivity methods must be employed for determining which device characteristics can be determined at early-times. The results of these sensitivities and trends aid a Monte Carlo Filtering matching algorithm that accurately determines yield, fuel-type, mass, and height-of-burst from hypothetical photon emissions from simplified Fat Man and Little Boy design derivatives. Additionally, signatures emanating from nuclear cloud rise models between approximately 3 and 60 seconds refined the results from the Monte Carlo Filtering algorithm, reducing uncertainty and improving accuracy. Superior Monte Carlo Filtering accuracy and lowered uncertainty indicates promise of using signatures from nuclear cloud rise as diagnostic indicators, if earlier data is destroyed or unavailable. Additionally, experimental photon emission sensitivities were shown with varying masses of Pu-239 within 0.01 seconds using select energy ranges from the 47-group photon energy structure. The derived early signatures may provide policy makers with empirical attribution evidence when combined with intelligence from other collection disciplines.","abstract_has_math":false,"creators":["Redd, Evan M."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Erickson, Anna S."],"committee_chairs":[],"committee_members":["Sjoden, Glenn","Shannon, Michael","Stulberg, Adam","Grogan, Brandon"],"year":2017,"date_issued":"2017-11-21","date_published":"2017-11-21","updated_at":"2026-11-19T05:05:22Z","subjects":["Nuclear forensics","Post-detonation nuclear forensics","Peri-detonation nuclear forensics","Attribution","Sensitivity analysis","Monte Carlo Filtering"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/59282","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/59282","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F59282","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Erickson, Anna S."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sjoden, Glenn","Shannon, Michael","Stulberg, Adam","Grogan, Brandon"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Redd, Evan M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-22T21:13:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-22T21:13:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-12"]},{"key":"dc:date.issued","label":"Date","values":["2017-11-21"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2017"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2018-01-22T21:13:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["df2e2349-4cf3-4d53-89e5-adc9b56c9ac6"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear forensics","Post-detonation nuclear forensics","Peri-detonation nuclear forensics","Attribution","Sensitivity analysis","Monte Carlo Filtering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/59282"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An orphaned nuclear detonation in an urban environment would create enormous pressure on policy makers to act quickly requiring strong attribution evidence. To answer these needs, this research examines prompt emissions within 60 seconds after detonation. This time period is defined as peri-detonation nuclear forensics and supports traditional post-detonation nuclear forensics which focus on sample/particulate collection and analysis. The competing physical effects and number of unknowns that affect prompt emissions, global and local sensitivity methods must be employed for determining which device characteristics can be determined at early-times. The results of these sensitivities and trends aid a Monte Carlo Filtering matching algorithm that accurately determines yield, fuel-type, mass, and height-of-burst from hypothetical photon emissions from simplified Fat Man and Little Boy design derivatives. Additionally, signatures emanating from nuclear cloud rise models between approximately 3 and 60 seconds refined the results from the Monte Carlo Filtering algorithm, reducing uncertainty and improving accuracy. Superior Monte Carlo Filtering accuracy and lowered uncertainty indicates promise of using signatures from nuclear cloud rise as diagnostic indicators, if earlier data is destroyed or unavailable. Additionally, experimental photon emission sensitivities were shown with varying masses of Pu-239 within 0.01 seconds using select energy ranges from the 47-group photon energy structure. The derived early signatures may provide policy makers with empirical attribution evidence when combined with intelligence from other collection disciplines."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Sensitivity analysis and parameterization of passively measured prompt-diagnostic signatures from a nuclear detonation and the effects on early-time attribution"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Erickson, Anna S."],"dc:contributor.committeemember":["Sjoden, Glenn","Shannon, Michael","Stulberg, Adam","Grogan, Brandon"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Redd, Evan M."],"dc:date.accessioned":["2018-01-22T21:13:00Z"],"dc:date.available":["2018-01-22T21:13:00Z"],"dc:date.created":["2017-12"],"dc:date.issued":["2017-11-21"],"dc:date.submitted":["December 2017"],"dc:date.updated":["2018-01-22T21:13:00Z"],"dc:description.abstract":["An orphaned nuclear detonation in an urban environment would create enormous pressure on policy makers to act quickly requiring strong attribution evidence. To answer these needs, this research examines prompt emissions within 60 seconds after detonation. This time period is defined as peri-detonation nuclear forensics and supports traditional post-detonation nuclear forensics which focus on sample/particulate collection and analysis. The competing physical effects and number of unknowns that affect prompt emissions, global and local sensitivity methods must be employed for determining which device characteristics can be determined at early-times. The results of these sensitivities and trends aid a Monte Carlo Filtering matching algorithm that accurately determines yield, fuel-type, mass, and height-of-burst from hypothetical photon emissions from simplified Fat Man and Little Boy design derivatives. Additionally, signatures emanating from nuclear cloud rise models between approximately 3 and 60 seconds refined the results from the Monte Carlo Filtering algorithm, reducing uncertainty and improving accuracy. Superior Monte Carlo Filtering accuracy and lowered uncertainty indicates promise of using signatures from nuclear cloud rise as diagnostic indicators, if earlier data is destroyed or unavailable. Additionally, experimental photon emission sensitivities were shown with varying masses of Pu-239 within 0.01 seconds using select energy ranges from the 47-group photon energy structure. The derived early signatures may provide policy makers with empirical attribution evidence when combined with intelligence from other collection disciplines."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/59282"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["df2e2349-4cf3-4d53-89e5-adc9b56c9ac6"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Nuclear Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"],"dc:subject":["Nuclear forensics","Post-detonation nuclear forensics","Peri-detonation nuclear forensics","Attribution","Sensitivity analysis","Monte Carlo Filtering"],"dc:title":["Sensitivity analysis and parameterization of passively measured prompt-diagnostic signatures from a nuclear detonation and the effects on early-time attribution"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:05:22Z"}