{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/59800"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/59800","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Reduced-wire readout systems-on-chip for high-frequency intravascular ultrasound imaging","abstract":"The objective of the proposed research is to minimize and integrate intravascular ultrasound imaging (IVUS) system on a guidewire and to develop wireless data communication for general capacitive micromachined ultrasonic transducer (CMUT) based ultrasound imaging system. Several innovative system- and circuit-level techniques are proposed towards the development of CMUT modeling, optimizing front-end circuits, wireless data communication, and inductive power transmission to reduce the system size and the required number of interconnections. Since it provides real-time and high-resolution images of the arteries with negligible side effects, intravascular ultra- sound (IVUS) has been a common imaging modality for cardio-vascular interventions. Current solid-state IVUS catheters (3F-8.2F in diameter) are bulky, cannot reach to lesions in narrow arteries, and require an additional catheter exchange, prolonging the critical cardio-vascular procedures. To address this issue, the way to integrate ASIC and CMUT array on a guidewire by reducing the number of connections is proposed in this research. The proposed research presents three approaches to design and implement the reduced-wire IVUS system: 1) optimized the front-end circuit with properly modeled CMUT equivalent circuits, 2) on-chip quadrature sampler with time-division multiplexing (TDM) based on the synthetic aperture imaging algorithm, and 3) impulse-radio pulse width modulation (IR-PWM) for a wireless data acquisition.","abstract_html":"The objective of the proposed research is to minimize and integrate intravascular ultrasound imaging (IVUS) system on a guidewire and to develop wireless data communication for general capacitive micromachined ultrasonic transducer (CMUT) based ultrasound imaging system. Several innovative system- and circuit-level techniques are proposed towards the development of CMUT modeling, optimizing front-end circuits, wireless data communication, and inductive power transmission to reduce the system size and the required number of interconnections. Since it provides real-time and high-resolution images of the arteries with negligible side effects, intravascular ultra- sound (IVUS) has been a common imaging modality for cardio-vascular interventions. Current solid-state IVUS catheters (3F-8.2F in diameter) are bulky, cannot reach to lesions in narrow arteries, and require an additional catheter exchange, prolonging the critical cardio-vascular procedures. To address this issue, the way to integrate ASIC and CMUT array on a guidewire by reducing the number of connections is proposed in this research. The proposed research presents three approaches to design and implement the reduced-wire IVUS system: 1) optimized the front-end circuit with properly modeled CMUT equivalent circuits, 2) on-chip quadrature sampler with time-division multiplexing (TDM) based on the synthetic aperture imaging algorithm, and 3) impulse-radio pulse width modulation (IR-PWM) for a wireless data acquisition.","abstract_has_math":false,"creators":["Lim, Jaemyung"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Ghovanloo, Maysam"],"committee_chairs":[],"committee_members":["Degertekin, F. Levent","Ayazi, Farrokh","Rincón-Mora, Gabriel A.","Freear, Steven"],"year":2017,"date_issued":"2017-04-07","date_published":"2017-04-07","updated_at":"2026-11-19T04:12:52Z","subjects":["IVUS","Ultrasound imaging","Intravascular","Capacitive micromachined ultrasonic transducer","CMUT"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/59800","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/59800","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F59800","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ghovanloo, Maysam"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Degertekin, F. Levent","Ayazi, Farrokh","Rincón-Mora, Gabriel A.","Freear, Steven"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Lim, Jaemyung"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-05-31T18:09:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-05-31T18:09:27Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-05"]},{"key":"dc:date.issued","label":"Date","values":["2017-04-07"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2017"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2018-05-31T18:09:29Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["IVUS","Ultrasound imaging","Intravascular","Capacitive micromachined ultrasonic transducer","CMUT"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/59800"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of the proposed research is to minimize and integrate intravascular ultrasound imaging (IVUS) system on a guidewire and to develop wireless data communication for general capacitive micromachined ultrasonic transducer (CMUT) based ultrasound imaging system. Several innovative system- and circuit-level techniques are proposed towards the development of CMUT modeling, optimizing front-end circuits, wireless data communication, and inductive power transmission to reduce the system size and the required number of interconnections. Since it provides real-time and high-resolution images of the arteries with negligible side effects, intravascular ultra- sound (IVUS) has been a common imaging modality for cardio-vascular interventions. Current solid-state IVUS catheters (3F-8.2F in diameter) are bulky, cannot reach to lesions in narrow arteries, and require an additional catheter exchange, prolonging the critical cardio-vascular procedures. To address this issue, the way to integrate ASIC and CMUT array on a guidewire by reducing the number of connections is proposed in this research. The proposed research presents three approaches to design and implement the reduced-wire IVUS system: 1) optimized the front-end circuit with properly modeled CMUT equivalent circuits, 2) on-chip quadrature sampler with time-division multiplexing (TDM) based on the synthetic aperture imaging algorithm, and 3) impulse-radio pulse width modulation (IR-PWM) for a wireless data acquisition."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Reduced-wire readout systems-on-chip for high-frequency intravascular ultrasound imaging"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ghovanloo, Maysam"],"dc:contributor.committeemember":["Degertekin, F. Levent","Ayazi, Farrokh","Rincón-Mora, Gabriel A.","Freear, Steven"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Lim, Jaemyung"],"dc:date.accessioned":["2018-05-31T18:09:27Z"],"dc:date.available":["2018-05-31T18:09:27Z"],"dc:date.created":["2017-05"],"dc:date.issued":["2017-04-07"],"dc:date.submitted":["May 2017"],"dc:date.updated":["2018-05-31T18:09:29Z"],"dc:description.abstract":["The objective of the proposed research is to minimize and integrate intravascular ultrasound imaging (IVUS) system on a guidewire and to develop wireless data communication for general capacitive micromachined ultrasonic transducer (CMUT) based ultrasound imaging system. Several innovative system- and circuit-level techniques are proposed towards the development of CMUT modeling, optimizing front-end circuits, wireless data communication, and inductive power transmission to reduce the system size and the required number of interconnections. Since it provides real-time and high-resolution images of the arteries with negligible side effects, intravascular ultra- sound (IVUS) has been a common imaging modality for cardio-vascular interventions. Current solid-state IVUS catheters (3F-8.2F in diameter) are bulky, cannot reach to lesions in narrow arteries, and require an additional catheter exchange, prolonging the critical cardio-vascular procedures. To address this issue, the way to integrate ASIC and CMUT array on a guidewire by reducing the number of connections is proposed in this research. The proposed research presents three approaches to design and implement the reduced-wire IVUS system: 1) optimized the front-end circuit with properly modeled CMUT equivalent circuits, 2) on-chip quadrature sampler with time-division multiplexing (TDM) based on the synthetic aperture imaging algorithm, and 3) impulse-radio pulse width modulation (IR-PWM) for a wireless data acquisition."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/59800"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["IVUS","Ultrasound imaging","Intravascular","Capacitive micromachined ultrasonic transducer","CMUT"],"dc:title":["Reduced-wire readout systems-on-chip for high-frequency intravascular ultrasound imaging"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T04:12:52Z"}