{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/59939"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/59939","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Bioluminescent calcium indicator protein and gold nanoparticle-enhanced bioluminescence","abstract":"Bioluminescent proteins have been extensively used as a light emission source for many fusion proteins and have a wide range of applications in imaging and cell signaling studies. In this study, the smallest known luciferase from the marine copepod, Gaussia princeps, was used to engineer novel bioluminescent sensors and novel methods to enhance bioluminescence intensity. In the First part of the study, two bioluminescent calcium sensors were developed, which were composed of a variant of Gaussia luciferase (sbGLuc) and the fluorescent calcium indicator protein, GCaMP6s. The two designs allowed bioluminescence resonance energy transfer (BRET) and they exhibited excellent dynamic range. In the Second part of the study, several strategies to enhance bioluminescence by conjugating sbGLuc with gold nanoparticles were carefully examined. On average, 26% enhancement on bioluminescence was achieved. The new sensors together with the gold nanoparticle-enhanced bioluminescence should be useful for various studies in various fields such as neuroscience and cell biology.","abstract_html":"Bioluminescent proteins have been extensively used as a light emission source for many fusion proteins and have a wide range of applications in imaging and cell signaling studies. In this study, the smallest known luciferase from the marine copepod, Gaussia princeps, was used to engineer novel bioluminescent sensors and novel methods to enhance bioluminescence intensity. In the First part of the study, two bioluminescent calcium sensors were developed, which were composed of a variant of Gaussia luciferase (sbGLuc) and the fluorescent calcium indicator protein, GCaMP6s. The two designs allowed bioluminescence resonance energy transfer (BRET) and they exhibited excellent dynamic range. In the Second part of the study, several strategies to enhance bioluminescence by conjugating sbGLuc with gold nanoparticles were carefully examined. On average, 26% enhancement on bioluminescence was achieved. The new sensors together with the gold nanoparticle-enhanced bioluminescence should be useful for various studies in various fields such as neuroscience and cell biology.","abstract_has_math":false,"creators":["Wang, Zuhui"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Gross, Robert E."],"committee_chairs":[],"committee_members":["Konstantinidis, Kostas T.","Cheung, Lily S."],"year":2018,"date_issued":"2018-04-25","date_published":"2018-04-25","updated_at":"2026-11-19T06:07:51Z","subjects":["Bioluminescence","Gaussia luciferase","Calcium indicator","Genetically encoded calcium indicator","GCaMP","Gold nanoparticle","Bioluminescence enhancement","Ni-NTA-Au"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/59939","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/59939","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F59939","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gross, Robert E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Konstantinidis, Kostas T.","Cheung, Lily S."]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Wang, Zuhui"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-05-31T18:17:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-05-31T18:17:08Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-05"]},{"key":"dc:date.issued","label":"Date","values":["2018-04-25"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2018"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2018-05-31T18:17:08Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["89002865-712a-460d-b3f2-d6fa13e129fd"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Bioengineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["a5c9fe8c-5d03-4de6-a761-459fb2af0dea"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bioluminescence","Gaussia luciferase","Calcium indicator","Genetically encoded calcium indicator","GCaMP","Gold nanoparticle","Bioluminescence enhancement","Ni-NTA-Au"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/59939"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Bioluminescent proteins have been extensively used as a light emission source for many fusion proteins and have a wide range of applications in imaging and cell signaling studies. In this study, the smallest known luciferase from the marine copepod, Gaussia princeps, was used to engineer novel bioluminescent sensors and novel methods to enhance bioluminescence intensity. In the First part of the study, two bioluminescent calcium sensors were developed, which were composed of a variant of Gaussia luciferase (sbGLuc) and the fluorescent calcium indicator protein, GCaMP6s. The two designs allowed bioluminescence resonance energy transfer (BRET) and they exhibited excellent dynamic range. In the Second part of the study, several strategies to enhance bioluminescence by conjugating sbGLuc with gold nanoparticles were carefully examined. On average, 26% enhancement on bioluminescence was achieved. The new sensors together with the gold nanoparticle-enhanced bioluminescence should be useful for various studies in various fields such as neuroscience and cell biology."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Bioluminescent calcium indicator protein and gold nanoparticle-enhanced bioluminescence"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gross, Robert E."],"dc:contributor.committeemember":["Konstantinidis, Kostas T.","Cheung, Lily S."],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Wang, Zuhui"],"dc:date.accessioned":["2018-05-31T18:17:08Z"],"dc:date.available":["2018-05-31T18:17:08Z"],"dc:date.created":["2018-05"],"dc:date.issued":["2018-04-25"],"dc:date.submitted":["May 2018"],"dc:date.updated":["2018-05-31T18:17:08Z"],"dc:description.abstract":["Bioluminescent proteins have been extensively used as a light emission source for many fusion proteins and have a wide range of applications in imaging and cell signaling studies. In this study, the smallest known luciferase from the marine copepod, Gaussia princeps, was used to engineer novel bioluminescent sensors and novel methods to enhance bioluminescence intensity. In the First part of the study, two bioluminescent calcium sensors were developed, which were composed of a variant of Gaussia luciferase (sbGLuc) and the fluorescent calcium indicator protein, GCaMP6s. The two designs allowed bioluminescence resonance energy transfer (BRET) and they exhibited excellent dynamic range. In the Second part of the study, several strategies to enhance bioluminescence by conjugating sbGLuc with gold nanoparticles were carefully examined. On average, 26% enhancement on bioluminescence was achieved. The new sensors together with the gold nanoparticle-enhanced bioluminescence should be useful for various studies in various fields such as neuroscience and cell biology."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/59939"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["89002865-712a-460d-b3f2-d6fa13e129fd"],"dc:relation.ispartofseries":["Master of Science in Bioengineering"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["a5c9fe8c-5d03-4de6-a761-459fb2af0dea"],"dc:subject":["Bioluminescence","Gaussia luciferase","Calcium indicator","Genetically encoded calcium indicator","GCaMP","Gold nanoparticle","Bioluminescence enhancement","Ni-NTA-Au"],"dc:title":["Bioluminescent calcium indicator protein and gold nanoparticle-enhanced bioluminescence"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T06:07:51Z"}