{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/59954"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/59954","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Positional estimation of soft actuators through embedded sensing","abstract":"Soft robotic systems are prone to bending in undesired modes due to the compliant materials used to fabricate them. These systems use pneumatic soft actuators relying on internal pressure to induce specific deformations. Controlling soft actuators requires system modeling, specifically in systems of multiple actuators. Acquiring accurate models through analytical methods is challenging due to embedded components constraining elastic deformations of the body. A less arduous approach to this challenge is observing system parameters through integrated sensing to develop an estimated model. As packaged soft sensing components are limited, research and development of the physical sensor and technique for implementation is required. Developing these methods involves mechanical design of components, electronic instrumentation, placement for target deformations, interpretation of response for embedded control, and benchmarking performance. The documentation of these attempts at sensor development serves to expand the toolbox of techniques for sensing in soft robotic bodies. Two approaches were made to the process. The first involved embedding conductive fluidic strain sensors in a bidirectional soft actuator of an assistive grasp prosthetic to characterize the undesired modes of deformation it was experiencing. Sensors were placed to observe the intended mode of bending as well as undesired rotational sag and twist of the actuator body. These sensors provided haptic feedback of actuator position that enabled users to correctly identify grasp in 83.3% of responses. The second was the design and fabrication of a soft grasp prosthetic incorporating control from embedded positional sensing. The primary grasping actuators were deployed with an embedded fiber optic array monitoring reflectance against an internal diaphragm. These sensor embedded actuators were employed in feedback control to independently alter grasp configuration to objects of varying shapes.","abstract_html":"Soft robotic systems are prone to bending in undesired modes due to the compliant materials used to fabricate them. These systems use pneumatic soft actuators relying on internal pressure to induce specific deformations. Controlling soft actuators requires system modeling, specifically in systems of multiple actuators. Acquiring accurate models through analytical methods is challenging due to embedded components constraining elastic deformations of the body. A less arduous approach to this challenge is observing system parameters through integrated sensing to develop an estimated model. As packaged soft sensing components are limited, research and development of the physical sensor and technique for implementation is required. Developing these methods involves mechanical design of components, electronic instrumentation, placement for target deformations, interpretation of response for embedded control, and benchmarking performance. The documentation of these attempts at sensor development serves to expand the toolbox of techniques for sensing in soft robotic bodies. Two approaches were made to the process. The first involved embedding conductive fluidic strain sensors in a bidirectional soft actuator of an assistive grasp prosthetic to characterize the undesired modes of deformation it was experiencing. Sensors were placed to observe the intended mode of bending as well as undesired rotational sag and twist of the actuator body. These sensors provided haptic feedback of actuator position that enabled users to correctly identify grasp in 83.3% of responses. The second was the design and fabrication of a soft grasp prosthetic incorporating control from embedded positional sensing. The primary grasping actuators were deployed with an embedded fiber optic array monitoring reflectance against an internal diaphragm. These sensor embedded actuators were employed in feedback control to independently alter grasp configuration to objects of varying shapes.","abstract_has_math":false,"creators":["Hart, Alexander M."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Hammond, Frank L., III"],"committee_chairs":[],"committee_members":["Dorozhkin, Dennis","Ueda, Jun"],"year":2018,"date_issued":"2018-04-26","date_published":"2018-04-26","updated_at":"2026-11-19T06:00:13Z","subjects":["Robotics","Soft robotics","Compliant systems","Embedded sensing","Sensing","Kinematic","Feedback control"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/59954","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/59954","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F59954","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hammond, Frank L., III"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Dorozhkin, Dennis","Ueda, Jun"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Hart, Alexander M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-05-31T18:17:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-05-31T18:17:31Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-05"]},{"key":"dc:date.issued","label":"Date","values":["2018-04-26"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2018"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2018-05-31T18:17:31Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["25430b41-a2e6-4931-9877-41bf8c4a6f2a"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Robotics","Soft robotics","Compliant systems","Embedded sensing","Sensing","Kinematic","Feedback control"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/59954"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Soft robotic systems are prone to bending in undesired modes due to the compliant materials used to fabricate them. These systems use pneumatic soft actuators relying on internal pressure to induce specific deformations. Controlling soft actuators requires system modeling, specifically in systems of multiple actuators. Acquiring accurate models through analytical methods is challenging due to embedded components constraining elastic deformations of the body. A less arduous approach to this challenge is observing system parameters through integrated sensing to develop an estimated model. As packaged soft sensing components are limited, research and development of the physical sensor and technique for implementation is required. Developing these methods involves mechanical design of components, electronic instrumentation, placement for target deformations, interpretation of response for embedded control, and benchmarking performance. The documentation of these attempts at sensor development serves to expand the toolbox of techniques for sensing in soft robotic bodies. Two approaches were made to the process. The first involved embedding conductive fluidic strain sensors in a bidirectional soft actuator of an assistive grasp prosthetic to characterize the undesired modes of deformation it was experiencing. Sensors were placed to observe the intended mode of bending as well as undesired rotational sag and twist of the actuator body. These sensors provided haptic feedback of actuator position that enabled users to correctly identify grasp in 83.3% of responses. The second was the design and fabrication of a soft grasp prosthetic incorporating control from embedded positional sensing. The primary grasping actuators were deployed with an embedded fiber optic array monitoring reflectance against an internal diaphragm. These sensor embedded actuators were employed in feedback control to independently alter grasp configuration to objects of varying shapes."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Positional estimation of soft actuators through embedded sensing"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hammond, Frank L., III"],"dc:contributor.committeemember":["Dorozhkin, Dennis","Ueda, Jun"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Hart, Alexander M."],"dc:date.accessioned":["2018-05-31T18:17:31Z"],"dc:date.available":["2018-05-31T18:17:31Z"],"dc:date.created":["2018-05"],"dc:date.issued":["2018-04-26"],"dc:date.submitted":["May 2018"],"dc:date.updated":["2018-05-31T18:17:31Z"],"dc:description.abstract":["Soft robotic systems are prone to bending in undesired modes due to the compliant materials used to fabricate them. These systems use pneumatic soft actuators relying on internal pressure to induce specific deformations. Controlling soft actuators requires system modeling, specifically in systems of multiple actuators. Acquiring accurate models through analytical methods is challenging due to embedded components constraining elastic deformations of the body. A less arduous approach to this challenge is observing system parameters through integrated sensing to develop an estimated model. As packaged soft sensing components are limited, research and development of the physical sensor and technique for implementation is required. Developing these methods involves mechanical design of components, electronic instrumentation, placement for target deformations, interpretation of response for embedded control, and benchmarking performance. The documentation of these attempts at sensor development serves to expand the toolbox of techniques for sensing in soft robotic bodies. Two approaches were made to the process. The first involved embedding conductive fluidic strain sensors in a bidirectional soft actuator of an assistive grasp prosthetic to characterize the undesired modes of deformation it was experiencing. Sensors were placed to observe the intended mode of bending as well as undesired rotational sag and twist of the actuator body. These sensors provided haptic feedback of actuator position that enabled users to correctly identify grasp in 83.3% of responses. The second was the design and fabrication of a soft grasp prosthetic incorporating control from embedded positional sensing. The primary grasping actuators were deployed with an embedded fiber optic array monitoring reflectance against an internal diaphragm. These sensor embedded actuators were employed in feedback control to independently alter grasp configuration to objects of varying shapes."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/59954"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["25430b41-a2e6-4931-9877-41bf8c4a6f2a"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Robotics","Soft robotics","Compliant systems","Embedded sensing","Sensing","Kinematic","Feedback control"],"dc:title":["Positional estimation of soft actuators through embedded sensing"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T06:00:13Z"}