{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/60675"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/60675","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Application of model predictive control to heating and cooling of off-grid shelters","abstract":"An increasing concern at off-grid forward operating bases (FOBs), disaster relief camps, refugee aid camps and other encampments is the rising cost of supplying and sustaining shelters to accommodate the occupant(s). This is due to high risk burdened costs of liquid fuel deliveries, needed for local electricity generation in remote, and often hostile regions, where such contingency bases are located. A significant part of the non-combat mission related energy consumption in such bases is towards the heating and cooling of shelters. The Environmental Control Unit (ECU) for a shelter, consisting of the components and controls of a packaged terminal air conditioner & heat pump, is operated with a simple set-point temperature control. For such shelters, more efficient use of energy can be accomplished by applying a model predictive control (MPC) approach to the ECU. MPC selects the most fuel efficient operation of the shelter ECU, based on shelter size, materials and construction, internal thermal loads, weather profile, including wind speed, solar insolation, infiltration, and ground coupling. The thesis demonstrates a first-of-its-kind, more energy-efficient and more thermally comfort application of the MPC approach on an Alaska soft shell shelter, equipped with an ECU, by performing a combination of MATLAB and EnergyPlus modeling.","abstract_html":"An increasing concern at off-grid forward operating bases (FOBs), disaster relief camps, refugee aid camps and other encampments is the rising cost of supplying and sustaining shelters to accommodate the occupant(s). This is due to high risk burdened costs of liquid fuel deliveries, needed for local electricity generation in remote, and often hostile regions, where such contingency bases are located. A significant part of the non-combat mission related energy consumption in such bases is towards the heating and cooling of shelters. The Environmental Control Unit (ECU) for a shelter, consisting of the components and controls of a packaged terminal air conditioner &amp; heat pump, is operated with a simple set-point temperature control. For such shelters, more efficient use of energy can be accomplished by applying a model predictive control (MPC) approach to the ECU. MPC selects the most fuel efficient operation of the shelter ECU, based on shelter size, materials and construction, internal thermal loads, weather profile, including wind speed, solar insolation, infiltration, and ground coupling. The thesis demonstrates a first-of-its-kind, more energy-efficient and more thermally comfort application of the MPC approach on an Alaska soft shell shelter, equipped with an ECU, by performing a combination of MATLAB and EnergyPlus modeling.","abstract_has_math":false,"creators":["De, Sumit Kumar"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Joshi, Yogendra"],"committee_chairs":[],"committee_members":["Kumar, Satish","Graham, Samuel"],"year":2017,"date_issued":"2017-08-31","date_published":"2017-08-31","updated_at":"2026-11-19T05:56:25Z","subjects":["Field application","Military","Model predictive control","Off-grid","Shelter","Forward operating base","Energy efficiency","Thermal comfort","MATLAB","EnergyPlus","MLE+","Linux","Ubuntu","EIO application","Microgrid","Disaster relief camp","Refugee aid camp","Environmental control unit","Liquid fuel","Heating ventilation and air conditioning","HVAC"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/60675","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/60675","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F60675","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Joshi, Yogendra"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kumar, Satish","Graham, Samuel"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["De, Sumit Kumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-01-16T17:20:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-01-16T17:20:07Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-12"]},{"key":"dc:date.issued","label":"Date","values":["2017-08-31"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2017"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-01-16T17:20:07Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["63ef328b-076b-44b7-92a9-0f7dd03fa1fa"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Field application","Military","Model predictive control","Off-grid","Shelter","Forward operating base","Energy efficiency","Thermal comfort","MATLAB","EnergyPlus","MLE+","Linux","Ubuntu","EIO application","Microgrid","Disaster relief camp","Refugee aid camp","Environmental control unit","Liquid fuel","Heating ventilation and air conditioning","HVAC"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/60675"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An increasing concern at off-grid forward operating bases (FOBs), disaster relief camps, refugee aid camps and other encampments is the rising cost of supplying and sustaining shelters to accommodate the occupant(s). This is due to high risk burdened costs of liquid fuel deliveries, needed for local electricity generation in remote, and often hostile regions, where such contingency bases are located. A significant part of the non-combat mission related energy consumption in such bases is towards the heating and cooling of shelters. The Environmental Control Unit (ECU) for a shelter, consisting of the components and controls of a packaged terminal air conditioner & heat pump, is operated with a simple set-point temperature control. For such shelters, more efficient use of energy can be accomplished by applying a model predictive control (MPC) approach to the ECU. MPC selects the most fuel efficient operation of the shelter ECU, based on shelter size, materials and construction, internal thermal loads, weather profile, including wind speed, solar insolation, infiltration, and ground coupling. The thesis demonstrates a first-of-its-kind, more energy-efficient and more thermally comfort application of the MPC approach on an Alaska soft shell shelter, equipped with an ECU, by performing a combination of MATLAB and EnergyPlus modeling."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Application of model predictive control to heating and cooling of off-grid shelters"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Joshi, Yogendra"],"dc:contributor.committeemember":["Kumar, Satish","Graham, Samuel"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["De, Sumit Kumar"],"dc:date.accessioned":["2019-01-16T17:20:07Z"],"dc:date.available":["2019-01-16T17:20:07Z"],"dc:date.created":["2017-12"],"dc:date.issued":["2017-08-31"],"dc:date.submitted":["December 2017"],"dc:date.updated":["2019-01-16T17:20:07Z"],"dc:description.abstract":["An increasing concern at off-grid forward operating bases (FOBs), disaster relief camps, refugee aid camps and other encampments is the rising cost of supplying and sustaining shelters to accommodate the occupant(s). This is due to high risk burdened costs of liquid fuel deliveries, needed for local electricity generation in remote, and often hostile regions, where such contingency bases are located. A significant part of the non-combat mission related energy consumption in such bases is towards the heating and cooling of shelters. The Environmental Control Unit (ECU) for a shelter, consisting of the components and controls of a packaged terminal air conditioner & heat pump, is operated with a simple set-point temperature control. For such shelters, more efficient use of energy can be accomplished by applying a model predictive control (MPC) approach to the ECU. MPC selects the most fuel efficient operation of the shelter ECU, based on shelter size, materials and construction, internal thermal loads, weather profile, including wind speed, solar insolation, infiltration, and ground coupling. The thesis demonstrates a first-of-its-kind, more energy-efficient and more thermally comfort application of the MPC approach on an Alaska soft shell shelter, equipped with an ECU, by performing a combination of MATLAB and EnergyPlus modeling."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/60675"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["63ef328b-076b-44b7-92a9-0f7dd03fa1fa"],"dc:relation.ispartofseries":["Master of Science in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"],"dc:subject":["Field application","Military","Model predictive control","Off-grid","Shelter","Forward operating base","Energy efficiency","Thermal comfort","MATLAB","EnergyPlus","MLE+","Linux","Ubuntu","EIO application","Microgrid","Disaster relief camp","Refugee aid camp","Environmental control unit","Liquid fuel","Heating ventilation and air conditioning","HVAC"],"dc:title":["Application of model predictive control to heating and cooling of off-grid shelters"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:56:25Z"}