{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/60779"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/60779","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"System configuration for proportional control of an assistive technology for patients with cervical spinal cord injuries","abstract":"Prior Work in the GTBionics Lab at Georgia Tech has lead to the design of an assistive technology device for people with quadriplegia in the form of a wearable headset incorporating multiple magnetic sensors for measuring magnetic fields generated by a rare-earth magnet placed on a patientâ€™s tongue. The aim is to track this magnet, and thereby the tongueâ€™s position, and then use those measurements to issue commands to a computer or smart phone. Past versions of the headset have used classification techniques to accomplish this, but it has been a desideratum to provide more refined tracking and proportional control. The intended nonlinear filtering algorithms require model estimation. Performing estimation requires access to calibrated measurements with known sensor orientations and positions. The sensor positions are flexible to the user, so it is necessary to find these values without the use of specialized equipment. The presented research describes a sequence of methods to synthesize the sensor information and estimate the model parameters; implementation considerations and potential problems are also presented.","abstract_html":"Prior Work in the GTBionics Lab at Georgia Tech has lead to the design of an assistive technology device for people with quadriplegia in the form of a wearable headset incorporating multiple magnetic sensors for measuring magnetic fields generated by a rare-earth magnet placed on a patientâ€™s tongue. The aim is to track this magnet, and thereby the tongueâ€™s position, and then use those measurements to issue commands to a computer or smart phone. Past versions of the headset have used classification techniques to accomplish this, but it has been a desideratum to provide more refined tracking and proportional control. The intended nonlinear filtering algorithms require model estimation. Performing estimation requires access to calibrated measurements with known sensor orientations and positions. The sensor positions are flexible to the user, so it is necessary to find these values without the use of specialized equipment. The presented research describes a sequence of methods to synthesize the sensor information and estimate the model parameters; implementation considerations and potential problems are also presented.","abstract_has_math":false,"creators":["Parrish, Nathan VerDon"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Anderson, David V."],"committee_chairs":[],"committee_members":["Davenport, Mark A.","Klein, Benjamin D. B.","Inan, Omer T.","Kacher, Joshua P."],"year":2018,"date_issued":"2018-11-09","date_published":"2018-11-09","updated_at":"2026-11-19T05:01:40Z","subjects":["Magnetometer","Sensor calibration","Assistive technology","Spinal cord injury","Tongue"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/60779","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/60779","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F60779","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Anderson, David V."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Davenport, Mark A.","Klein, Benjamin D. B.","Inan, Omer T.","Kacher, Joshua P."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Parrish, Nathan VerDon"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-01-16T17:24:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-01-16T17:24:11Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-12"]},{"key":"dc:date.issued","label":"Date","values":["2018-11-09"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2018"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-01-16T17:24:12Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["eefeec08-2c7a-4e05-9f4b-7d25059e20a0"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Magnetometer","Sensor calibration","Assistive technology","Spinal cord injury","Tongue"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/60779"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Prior Work in the GTBionics Lab at Georgia Tech has lead to the design of an assistive technology device for people with quadriplegia in the form of a wearable headset incorporating multiple magnetic sensors for measuring magnetic fields generated by a rare-earth magnet placed on a patientâ€™s tongue. The aim is to track this magnet, and thereby the tongueâ€™s position, and then use those measurements to issue commands to a computer or smart phone. Past versions of the headset have used classification techniques to accomplish this, but it has been a desideratum to provide more refined tracking and proportional control. The intended nonlinear filtering algorithms require model estimation. Performing estimation requires access to calibrated measurements with known sensor orientations and positions. The sensor positions are flexible to the user, so it is necessary to find these values without the use of specialized equipment. The presented research describes a sequence of methods to synthesize the sensor information and estimate the model parameters; implementation considerations and potential problems are also presented."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["System configuration for proportional control of an assistive technology for patients with cervical spinal cord injuries"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Anderson, David V."],"dc:contributor.committeemember":["Davenport, Mark A.","Klein, Benjamin D. B.","Inan, Omer T.","Kacher, Joshua P."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Parrish, Nathan VerDon"],"dc:date.accessioned":["2019-01-16T17:24:11Z"],"dc:date.available":["2019-01-16T17:24:11Z"],"dc:date.created":["2018-12"],"dc:date.issued":["2018-11-09"],"dc:date.submitted":["December 2018"],"dc:date.updated":["2019-01-16T17:24:12Z"],"dc:description.abstract":["Prior Work in the GTBionics Lab at Georgia Tech has lead to the design of an assistive technology device for people with quadriplegia in the form of a wearable headset incorporating multiple magnetic sensors for measuring magnetic fields generated by a rare-earth magnet placed on a patientâ€™s tongue. The aim is to track this magnet, and thereby the tongueâ€™s position, and then use those measurements to issue commands to a computer or smart phone. Past versions of the headset have used classification techniques to accomplish this, but it has been a desideratum to provide more refined tracking and proportional control. The intended nonlinear filtering algorithms require model estimation. Performing estimation requires access to calibrated measurements with known sensor orientations and positions. The sensor positions are flexible to the user, so it is necessary to find these values without the use of specialized equipment. The presented research describes a sequence of methods to synthesize the sensor information and estimate the model parameters; implementation considerations and potential problems are also presented."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/60779"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["eefeec08-2c7a-4e05-9f4b-7d25059e20a0"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Magnetometer","Sensor calibration","Assistive technology","Spinal cord injury","Tongue"],"dc:title":["System configuration for proportional control of an assistive technology for patients with cervical spinal cord injuries"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:01:40Z"}