{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/60812"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/60812","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Rapid characterization of poor-quality medicines using mass spectrometry","abstract":"Communities worldwide, especially in the developing world, are afflicted with poor-quality medicines disguised as genuine medicines used for treatment of common infections. Poor-quality medicines range from expired genuine tablets to placebos containing toxins created by criminals. Numerous patients are left with untreated conditions, financial losses, and little confidence in the health system. The developing world struggles to identify and quantitate poor-quality antimalarial and antibiotic medicines. Portable devices employing robust laboratory techniques have the potential to turn the tide in this fight. Vast regions in the developing world lack laboratory analysis capabilities and therefore need portable instruments to perform medicinal quality evaluations. The portable devices lack the demonstrated capability to analyze all classes of poor-quality medicines. Results from tested devices reveal a significant gap in demonstrating the critical ability to distinguish poor-quality from genuine medicines. This study evaluated the Waters QDa mass spectrometer in identifying and quantitating common antimalarial and antibiotic medicines. This instrument correctly identified all poor-quality medicines among 7 common pharmaceutical treatments. Using a high-throughput easily customizable method, the QDa characterized all poor-quality medicines, both falsified and substandard. This capability is unparalleled among portable instruments. The QDa possesses the ability to become an instrumental asset in the fight against poor-quality medicines.","abstract_html":"Communities worldwide, especially in the developing world, are afflicted with poor-quality medicines disguised as genuine medicines used for treatment of common infections. Poor-quality medicines range from expired genuine tablets to placebos containing toxins created by criminals. Numerous patients are left with untreated conditions, financial losses, and little confidence in the health system. The developing world struggles to identify and quantitate poor-quality antimalarial and antibiotic medicines. Portable devices employing robust laboratory techniques have the potential to turn the tide in this fight. Vast regions in the developing world lack laboratory analysis capabilities and therefore need portable instruments to perform medicinal quality evaluations. The portable devices lack the demonstrated capability to analyze all classes of poor-quality medicines. Results from tested devices reveal a significant gap in demonstrating the critical ability to distinguish poor-quality from genuine medicines. This study evaluated the Waters QDa mass spectrometer in identifying and quantitating common antimalarial and antibiotic medicines. This instrument correctly identified all poor-quality medicines among 7 common pharmaceutical treatments. Using a high-throughput easily customizable method, the QDa characterized all poor-quality medicines, both falsified and substandard. This capability is unparalleled among portable instruments. The QDa possesses the ability to become an instrumental asset in the fight against poor-quality medicines.","abstract_has_math":false,"creators":["Donndelinger, David Vincent"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Chemistry and Biochemistry","school":null,"contributors":[],"advisors":["Fernández, Facundo M."],"committee_chairs":[],"committee_members":["Wu, Ronghu","Stockton, Amanda M."],"year":2018,"date_issued":"2018-11-19","date_published":"2018-11-19","updated_at":"2026-11-19T05:17:26Z","subjects":["Mass spectrometry","Rapid characterization","Poor-quality medicines"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/60812","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/60812","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F60812","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fernández, Facundo M."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wu, Ronghu","Stockton, Amanda M."]},{"key":"dc:contributor.department","label":"Department","values":["Chemistry and Biochemistry"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Chemistry and Biochemistry","College of Sciences"]},{"key":"dc:creator","label":"Author","values":["Donndelinger, David Vincent"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-01-16T17:25:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-01-16T17:25:29Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-12"]},{"key":"dc:date.issued","label":"Date","values":["2018-11-19"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2018"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-01-16T17:25:29Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["60fbfa01-4d0f-42eb-93b1-7577bf996e40"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Chemistry"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["f1725b93-3ab8-4c47-a4c3-3596c03d6f1e","85042be6-2d68-4e07-b384-e1f908fae48a"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["8954817e-f914-4a18-bccd-8e0ecaf17c10"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mass spectrometry","Rapid characterization","Poor-quality medicines"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/60812"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Communities worldwide, especially in the developing world, are afflicted with poor-quality medicines disguised as genuine medicines used for treatment of common infections. Poor-quality medicines range from expired genuine tablets to placebos containing toxins created by criminals. Numerous patients are left with untreated conditions, financial losses, and little confidence in the health system. The developing world struggles to identify and quantitate poor-quality antimalarial and antibiotic medicines. Portable devices employing robust laboratory techniques have the potential to turn the tide in this fight. Vast regions in the developing world lack laboratory analysis capabilities and therefore need portable instruments to perform medicinal quality evaluations. The portable devices lack the demonstrated capability to analyze all classes of poor-quality medicines. Results from tested devices reveal a significant gap in demonstrating the critical ability to distinguish poor-quality from genuine medicines. This study evaluated the Waters QDa mass spectrometer in identifying and quantitating common antimalarial and antibiotic medicines. This instrument correctly identified all poor-quality medicines among 7 common pharmaceutical treatments. Using a high-throughput easily customizable method, the QDa characterized all poor-quality medicines, both falsified and substandard. This capability is unparalleled among portable instruments. The QDa possesses the ability to become an instrumental asset in the fight against poor-quality medicines."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Rapid characterization of poor-quality medicines using mass spectrometry"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fernández, Facundo M."],"dc:contributor.committeemember":["Wu, Ronghu","Stockton, Amanda M."],"dc:contributor.department":["Chemistry and Biochemistry"],"dc:contributor.other":["School of Chemistry and Biochemistry","College of Sciences"],"dc:creator":["Donndelinger, David Vincent"],"dc:date.accessioned":["2019-01-16T17:25:29Z"],"dc:date.available":["2019-01-16T17:25:29Z"],"dc:date.created":["2018-12"],"dc:date.issued":["2018-11-19"],"dc:date.submitted":["December 2018"],"dc:date.updated":["2019-01-16T17:25:29Z"],"dc:description.abstract":["Communities worldwide, especially in the developing world, are afflicted with poor-quality medicines disguised as genuine medicines used for treatment of common infections. Poor-quality medicines range from expired genuine tablets to placebos containing toxins created by criminals. Numerous patients are left with untreated conditions, financial losses, and little confidence in the health system. The developing world struggles to identify and quantitate poor-quality antimalarial and antibiotic medicines. Portable devices employing robust laboratory techniques have the potential to turn the tide in this fight. Vast regions in the developing world lack laboratory analysis capabilities and therefore need portable instruments to perform medicinal quality evaluations. The portable devices lack the demonstrated capability to analyze all classes of poor-quality medicines. Results from tested devices reveal a significant gap in demonstrating the critical ability to distinguish poor-quality from genuine medicines. This study evaluated the Waters QDa mass spectrometer in identifying and quantitating common antimalarial and antibiotic medicines. This instrument correctly identified all poor-quality medicines among 7 common pharmaceutical treatments. Using a high-throughput easily customizable method, the QDa characterized all poor-quality medicines, both falsified and substandard. This capability is unparalleled among portable instruments. The QDa possesses the ability to become an instrumental asset in the fight against poor-quality medicines."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/60812"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["60fbfa01-4d0f-42eb-93b1-7577bf996e40"],"dc:relation.ispartofseries":["Master of Science in Chemistry"],"dc:relation.orgunit":["f1725b93-3ab8-4c47-a4c3-3596c03d6f1e","85042be6-2d68-4e07-b384-e1f908fae48a"],"dc:relation.seriesentity":["8954817e-f914-4a18-bccd-8e0ecaf17c10"],"dc:subject":["Mass spectrometry","Rapid characterization","Poor-quality medicines"],"dc:title":["Rapid characterization of poor-quality medicines using mass spectrometry"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:17:26Z"}