{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/61173"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/61173","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Regressing dexterous finger flexions using machine learning and multi-channel single element ultrasound transducers","abstract":"Human Machine Interfaces or \"HMI's\" come in many shapes and sizes. The mouse and keyboard is a typical and familiar HMI. In applications such as Virtual Reality or Music performance, a precise HMI for tracking finger movement is often required. Ultrasound, a safe and non-invasive imaging technique, has shown great promise as an alternative HMI interface that addresses the shortcomings of vision-based and glove-based sensors. This thesis develops a first-in-class system enabling real-time regression of individual and simultaneous finger flexions using single element ultrasound transducers. A comprehensive dataset of ultrasound signals is collected is collected from a study of 10 users. A series of machine learning experiments using this dataset demonstrate promising results supporting the use of single element transducers as a HMI device.","abstract_html":"Human Machine Interfaces or &quot;HMI&#x27;s&quot; come in many shapes and sizes. The mouse and keyboard is a typical and familiar HMI. In applications such as Virtual Reality or Music performance, a precise HMI for tracking finger movement is often required. Ultrasound, a safe and non-invasive imaging technique, has shown great promise as an alternative HMI interface that addresses the shortcomings of vision-based and glove-based sensors. This thesis develops a first-in-class system enabling real-time regression of individual and simultaneous finger flexions using single element ultrasound transducers. A comprehensive dataset of ultrasound signals is collected is collected from a study of 10 users. A series of machine learning experiments using this dataset demonstrate promising results supporting the use of single element transducers as a HMI device.","abstract_has_math":false,"creators":["Hantrakul, Lamtharn"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Music","school":null,"contributors":[],"advisors":["Weinberg, Gil"],"committee_chairs":[],"committee_members":["Lerch, Alexander","Bretan, Mason","Boots, Byron"],"year":2018,"date_issued":"2018-04-27","date_published":"2018-04-27","updated_at":"2026-11-19T05:13:42Z","subjects":["Machine learning","Ultrasound"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/61173","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/61173","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F61173","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Weinberg, Gil"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Lerch, Alexander","Bretan, Mason","Boots, Byron"]},{"key":"dc:contributor.department","label":"Department","values":["Music"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Design","School of Music"]},{"key":"dc:creator","label":"Author","values":["Hantrakul, Lamtharn"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-05-29T14:00:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-05-29T14:00:12Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-05"]},{"key":"dc:date.issued","label":"Date","values":["2018-04-27"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2018"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-05-29T14:00:12Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["f3feda3b-c805-4675-842e-01a40f8b40a4"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Music Technology"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c997b6a0-7e87-4a6f-b6fc-932d776ba8d0","92d2daaa-80f2-4d99-b464-ab7c1125fc55"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["bb52c603-2646-4dfa-a9b7-9f81b43c419a"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Machine learning","Ultrasound"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/61173"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Human Machine Interfaces or \"HMI's\" come in many shapes and sizes. The mouse and keyboard is a typical and familiar HMI. In applications such as Virtual Reality or Music performance, a precise HMI for tracking finger movement is often required. Ultrasound, a safe and non-invasive imaging technique, has shown great promise as an alternative HMI interface that addresses the shortcomings of vision-based and glove-based sensors. This thesis develops a first-in-class system enabling real-time regression of individual and simultaneous finger flexions using single element ultrasound transducers. A comprehensive dataset of ultrasound signals is collected is collected from a study of 10 users. A series of machine learning experiments using this dataset demonstrate promising results supporting the use of single element transducers as a HMI device."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Regressing dexterous finger flexions using machine learning and multi-channel single element ultrasound transducers"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Weinberg, Gil"],"dc:contributor.committeemember":["Lerch, Alexander","Bretan, Mason","Boots, Byron"],"dc:contributor.department":["Music"],"dc:contributor.other":["College of Design","School of Music"],"dc:creator":["Hantrakul, Lamtharn"],"dc:date.accessioned":["2019-05-29T14:00:12Z"],"dc:date.available":["2019-05-29T14:00:12Z"],"dc:date.created":["2018-05"],"dc:date.issued":["2018-04-27"],"dc:date.submitted":["May 2018"],"dc:date.updated":["2019-05-29T14:00:12Z"],"dc:description.abstract":["Human Machine Interfaces or \"HMI's\" come in many shapes and sizes. The mouse and keyboard is a typical and familiar HMI. In applications such as Virtual Reality or Music performance, a precise HMI for tracking finger movement is often required. Ultrasound, a safe and non-invasive imaging technique, has shown great promise as an alternative HMI interface that addresses the shortcomings of vision-based and glove-based sensors. This thesis develops a first-in-class system enabling real-time regression of individual and simultaneous finger flexions using single element ultrasound transducers. A comprehensive dataset of ultrasound signals is collected is collected from a study of 10 users. A series of machine learning experiments using this dataset demonstrate promising results supporting the use of single element transducers as a HMI device."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/61173"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["f3feda3b-c805-4675-842e-01a40f8b40a4"],"dc:relation.ispartofseries":["Master of Science in Music Technology"],"dc:relation.orgunit":["c997b6a0-7e87-4a6f-b6fc-932d776ba8d0","92d2daaa-80f2-4d99-b464-ab7c1125fc55"],"dc:relation.seriesentity":["bb52c603-2646-4dfa-a9b7-9f81b43c419a"],"dc:subject":["Machine learning","Ultrasound"],"dc:title":["Regressing dexterous finger flexions using machine learning and multi-channel single element ultrasound transducers"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:13:42Z"}