{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/61188"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/61188","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Modeling, design, fabrication and characterization of miniaturized, high-current handling and high-efficiency inductors","abstract":"Analytical models were developed to design magnetic materials with desired permeability and frequency stability. Two loss mechanisms, eddy current loss and ferromagnetic resonance (FMR) loss, were included in the models to capture behaviors of magnetic materials at high frequency. Based on the models, magnetic materials were designed to have 2D flake shape for both high permeability and high-frequency stability. The accuracy of developed models were proofed by the good correlation between calculated and measured permeability data. By incorporating the designed magnetic flakes as the cores, two types of magnetic-core inductor, spiral inductors and solenoid inductors, were modeled and designed by using finite element models (FEMs) to achieve high current-handling. Furthermore, innovative substrate-compatible processes were developed to fabricate the designed magnetic-core inductors. One process named as core-less process was developed to fabricate the spiral inductors. Another process named as cavity-embedding process was developed to fabricate the solenoid inductors. Electrical characterizations were performed to measure the frequency-dependent and current-dependent inductance of fabricated inductors. A good correlation between measurement and simulation was observed, indicating the accuracy of inductor FEMs.","abstract_html":"Analytical models were developed to design magnetic materials with desired permeability and frequency stability. Two loss mechanisms, eddy current loss and ferromagnetic resonance (FMR) loss, were included in the models to capture behaviors of magnetic materials at high frequency. Based on the models, magnetic materials were designed to have 2D flake shape for both high permeability and high-frequency stability. The accuracy of developed models were proofed by the good correlation between calculated and measured permeability data. By incorporating the designed magnetic flakes as the cores, two types of magnetic-core inductor, spiral inductors and solenoid inductors, were modeled and designed by using finite element models (FEMs) to achieve high current-handling. Furthermore, innovative substrate-compatible processes were developed to fabricate the designed magnetic-core inductors. One process named as core-less process was developed to fabricate the spiral inductors. Another process named as cavity-embedding process was developed to fabricate the solenoid inductors. Electrical characterizations were performed to measure the frequency-dependent and current-dependent inductance of fabricated inductors. A good correlation between measurement and simulation was observed, indicating the accuracy of inductor FEMs.","abstract_has_math":false,"creators":["Sun, Teng"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Materials Science and Engineering","school":null,"contributors":[],"advisors":["Tummala, Rao R."],"committee_chairs":[],"committee_members":["Qin, Dong","Vogel, Eric","Garmestani, Hamid","Raj, Pulugurtha Markondeya"],"year":2018,"date_issued":"2018-12-18","date_published":"2018-12-18","updated_at":"2026-11-19T03:56:20Z","subjects":["Magnetic materials","Power inductors","Substrate integration","Electronic packaging"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/61188","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/61188","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F61188","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Tummala, Rao R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Qin, Dong","Vogel, Eric","Garmestani, Hamid","Raj, Pulugurtha Markondeya"]},{"key":"dc:contributor.department","label":"Department","values":["Materials Science and Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Materials Science and Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Sun, Teng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-05-29T14:00:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-05-29T14:00:48Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-05"]},{"key":"dc:date.issued","label":"Date","values":["2018-12-18"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2019"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-05-29T14:00:48Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["fe05ddb2-e957-4584-ac88-58a197df62aa"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["21b5a45b-0b8a-4b69-a36b-6556f8426a35","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Magnetic materials","Power inductors","Substrate integration","Electronic packaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/61188"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Analytical models were developed to design magnetic materials with desired permeability and frequency stability. Two loss mechanisms, eddy current loss and ferromagnetic resonance (FMR) loss, were included in the models to capture behaviors of magnetic materials at high frequency. Based on the models, magnetic materials were designed to have 2D flake shape for both high permeability and high-frequency stability. The accuracy of developed models were proofed by the good correlation between calculated and measured permeability data. By incorporating the designed magnetic flakes as the cores, two types of magnetic-core inductor, spiral inductors and solenoid inductors, were modeled and designed by using finite element models (FEMs) to achieve high current-handling. Furthermore, innovative substrate-compatible processes were developed to fabricate the designed magnetic-core inductors. One process named as core-less process was developed to fabricate the spiral inductors. Another process named as cavity-embedding process was developed to fabricate the solenoid inductors. Electrical characterizations were performed to measure the frequency-dependent and current-dependent inductance of fabricated inductors. A good correlation between measurement and simulation was observed, indicating the accuracy of inductor FEMs."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Modeling, design, fabrication and characterization of miniaturized, high-current handling and high-efficiency inductors"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Tummala, Rao R."],"dc:contributor.committeemember":["Qin, Dong","Vogel, Eric","Garmestani, Hamid","Raj, Pulugurtha Markondeya"],"dc:contributor.department":["Materials Science and Engineering"],"dc:contributor.other":["School of Materials Science and Engineering","College of Engineering"],"dc:creator":["Sun, Teng"],"dc:date.accessioned":["2019-05-29T14:00:48Z"],"dc:date.available":["2019-05-29T14:00:48Z"],"dc:date.created":["2019-05"],"dc:date.issued":["2018-12-18"],"dc:date.submitted":["May 2019"],"dc:date.updated":["2019-05-29T14:00:48Z"],"dc:description.abstract":["Analytical models were developed to design magnetic materials with desired permeability and frequency stability. Two loss mechanisms, eddy current loss and ferromagnetic resonance (FMR) loss, were included in the models to capture behaviors of magnetic materials at high frequency. Based on the models, magnetic materials were designed to have 2D flake shape for both high permeability and high-frequency stability. The accuracy of developed models were proofed by the good correlation between calculated and measured permeability data. By incorporating the designed magnetic flakes as the cores, two types of magnetic-core inductor, spiral inductors and solenoid inductors, were modeled and designed by using finite element models (FEMs) to achieve high current-handling. Furthermore, innovative substrate-compatible processes were developed to fabricate the designed magnetic-core inductors. One process named as core-less process was developed to fabricate the spiral inductors. Another process named as cavity-embedding process was developed to fabricate the solenoid inductors. Electrical characterizations were performed to measure the frequency-dependent and current-dependent inductance of fabricated inductors. A good correlation between measurement and simulation was observed, indicating the accuracy of inductor FEMs."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/61188"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["fe05ddb2-e957-4584-ac88-58a197df62aa"],"dc:relation.orgunit":["21b5a45b-0b8a-4b69-a36b-6556f8426a35","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Magnetic materials","Power inductors","Substrate integration","Electronic packaging"],"dc:title":["Modeling, design, fabrication and characterization of miniaturized, high-current handling and high-efficiency inductors"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T03:56:20Z"}