{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/61263"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/61263","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Cuffless blood pressure monitoring technologies based on pulse transit time","abstract":"Cuffless sensing techniques for monitoring pulse transit time (PTT) to estimate blood pressure was proposed. Developing such techniques is imperative to providing an at-home solution that is more convenient than current monitoring systems. PTT, or the time interval for an arterial pulse wave to travel along the arterial wall from a proximal to a distal site, relative to the heart, has been shown in previous works to have an inverse relationship with blood pressure. However, limited techniques exist to conveniently measure PTT in daily life. This work focuses on developing two techniques for convenient PTT measurements using a scale-based and wearable approach. First, a scale-based approach utilizes full-body vibrations, called the ballistocardiogram, to provide a measurement of the pulse at a proximal location to the heart. By attaching a custom-made optical sensor on the foot and thus measuring a distal pulse timing, the scale-based approach captures true aortic pulse transit time and provides a superior estimation compared to conventional timing based methods. We further refined the measurement of the distal pulse by developing an array-based optical sensor and signal selection techniques to capture a pulse wave while a subject simply stands quietly to obtain a measurement. Second, a watch-based sensor, SeismoWatch, allows the user to sense pulse timings at the chest and the wrist. To acquire two timing references for PTT, an inertial sensor detects the vibrations of the chest associated with opening of the aorta, based on seismocardiography, and an optical sensor at the wrist measures the distal pulse wave. SeismoWatch is non-invasive and compact, allowing for convenient and portable blood pressure tracking.","abstract_html":"Cuffless sensing techniques for monitoring pulse transit time (PTT) to estimate blood pressure was proposed. Developing such techniques is imperative to providing an at-home solution that is more convenient than current monitoring systems. PTT, or the time interval for an arterial pulse wave to travel along the arterial wall from a proximal to a distal site, relative to the heart, has been shown in previous works to have an inverse relationship with blood pressure. However, limited techniques exist to conveniently measure PTT in daily life. This work focuses on developing two techniques for convenient PTT measurements using a scale-based and wearable approach. First, a scale-based approach utilizes full-body vibrations, called the ballistocardiogram, to provide a measurement of the pulse at a proximal location to the heart. By attaching a custom-made optical sensor on the foot and thus measuring a distal pulse timing, the scale-based approach captures true aortic pulse transit time and provides a superior estimation compared to conventional timing based methods. We further refined the measurement of the distal pulse by developing an array-based optical sensor and signal selection techniques to capture a pulse wave while a subject simply stands quietly to obtain a measurement. Second, a watch-based sensor, SeismoWatch, allows the user to sense pulse timings at the chest and the wrist. To acquire two timing references for PTT, an inertial sensor detects the vibrations of the chest associated with opening of the aorta, based on seismocardiography, and an optical sensor at the wrist measures the distal pulse wave. SeismoWatch is non-invasive and compact, allowing for convenient and portable blood pressure tracking.","abstract_has_math":false,"creators":["Carek, Andrew M."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Inan, Omer T."],"committee_chairs":[],"committee_members":["Wang, Hua","Butera, Robert","Farrokh, Ayazi","Etemadi, Mozziyar"],"year":2019,"date_issued":"2019-04-02","date_published":"2019-04-02","updated_at":"2026-11-19T05:59:24Z","subjects":["Cuffless blood pressure","Pulse transit time","Ballistocardiogram","Seismocardiogram"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/61263","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/61263","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F61263","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Inan, Omer T."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wang, Hua","Butera, Robert","Farrokh, Ayazi","Etemadi, Mozziyar"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Carek, Andrew M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-05-29T14:03:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-05-29T14:03:26Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-05"]},{"key":"dc:date.issued","label":"Date","values":["2019-04-02"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2019"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-05-29T14:03:26Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["fb82ce90-ad3a-45a6-b0e2-f1ee6fe6f744"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cuffless blood pressure","Pulse transit time","Ballistocardiogram","Seismocardiogram"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/61263"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cuffless sensing techniques for monitoring pulse transit time (PTT) to estimate blood pressure was proposed. Developing such techniques is imperative to providing an at-home solution that is more convenient than current monitoring systems. PTT, or the time interval for an arterial pulse wave to travel along the arterial wall from a proximal to a distal site, relative to the heart, has been shown in previous works to have an inverse relationship with blood pressure. However, limited techniques exist to conveniently measure PTT in daily life. This work focuses on developing two techniques for convenient PTT measurements using a scale-based and wearable approach. First, a scale-based approach utilizes full-body vibrations, called the ballistocardiogram, to provide a measurement of the pulse at a proximal location to the heart. By attaching a custom-made optical sensor on the foot and thus measuring a distal pulse timing, the scale-based approach captures true aortic pulse transit time and provides a superior estimation compared to conventional timing based methods. We further refined the measurement of the distal pulse by developing an array-based optical sensor and signal selection techniques to capture a pulse wave while a subject simply stands quietly to obtain a measurement. Second, a watch-based sensor, SeismoWatch, allows the user to sense pulse timings at the chest and the wrist. To acquire two timing references for PTT, an inertial sensor detects the vibrations of the chest associated with opening of the aorta, based on seismocardiography, and an optical sensor at the wrist measures the distal pulse wave. SeismoWatch is non-invasive and compact, allowing for convenient and portable blood pressure tracking."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Cuffless blood pressure monitoring technologies based on pulse transit time"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Inan, Omer T."],"dc:contributor.committeemember":["Wang, Hua","Butera, Robert","Farrokh, Ayazi","Etemadi, Mozziyar"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Carek, Andrew M."],"dc:date.accessioned":["2019-05-29T14:03:26Z"],"dc:date.available":["2019-05-29T14:03:26Z"],"dc:date.created":["2019-05"],"dc:date.issued":["2019-04-02"],"dc:date.submitted":["May 2019"],"dc:date.updated":["2019-05-29T14:03:26Z"],"dc:description.abstract":["Cuffless sensing techniques for monitoring pulse transit time (PTT) to estimate blood pressure was proposed. Developing such techniques is imperative to providing an at-home solution that is more convenient than current monitoring systems. PTT, or the time interval for an arterial pulse wave to travel along the arterial wall from a proximal to a distal site, relative to the heart, has been shown in previous works to have an inverse relationship with blood pressure. However, limited techniques exist to conveniently measure PTT in daily life. This work focuses on developing two techniques for convenient PTT measurements using a scale-based and wearable approach. First, a scale-based approach utilizes full-body vibrations, called the ballistocardiogram, to provide a measurement of the pulse at a proximal location to the heart. By attaching a custom-made optical sensor on the foot and thus measuring a distal pulse timing, the scale-based approach captures true aortic pulse transit time and provides a superior estimation compared to conventional timing based methods. We further refined the measurement of the distal pulse by developing an array-based optical sensor and signal selection techniques to capture a pulse wave while a subject simply stands quietly to obtain a measurement. Second, a watch-based sensor, SeismoWatch, allows the user to sense pulse timings at the chest and the wrist. To acquire two timing references for PTT, an inertial sensor detects the vibrations of the chest associated with opening of the aorta, based on seismocardiography, and an optical sensor at the wrist measures the distal pulse wave. SeismoWatch is non-invasive and compact, allowing for convenient and portable blood pressure tracking."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/61263"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["fb82ce90-ad3a-45a6-b0e2-f1ee6fe6f744"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Cuffless blood pressure","Pulse transit time","Ballistocardiogram","Seismocardiogram"],"dc:title":["Cuffless blood pressure monitoring technologies based on pulse transit time"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:59:24Z"}