{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/61652"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/61652","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Medical decision making - a personalized approach","abstract":"One of the challenges in medical decision making is the complexity, variability and uncertainty that exist in both patients and different treatment methods. In real practice, patients are different in their personal characteristics, drug response and treatment compliance. In this dissertation, we focus on developing mathematical foundation and computational tools that extract and utilize personalized information to improve the decision-making process for physicians (and patients). We first focus on the management of diabetes mellitus and develop a pharmacokinetic and pharmacodynamics (PK/PD) drug effect model to characterize the personalized dose response of patients receiving anti-diabetic drug therapy. Such personalized information is then incorporated in a first-of-its-kind mixed-integer program to quantitatively optimize each patient’s dose regimen. In a retrospective study, the optimized regimen gives better glycemic control with less drug used than the original regimen prescribed. The second part of the thesis focuses on the optimization of external radiotherapy. We developed a multi-objective direct aperture model that optimizes clinical objectives based on their personalized clinical priorities. A heuristic column generation algorithm that does not require dose information is developed and greatly reduces the total solution time. Moreover, a mixed-integer beam selection model is incorporated into this model to produce plans with better dose distribution than those with beam manually selected by human planner.","abstract_html":"One of the challenges in medical decision making is the complexity, variability and uncertainty that exist in both patients and different treatment methods. In real practice, patients are different in their personal characteristics, drug response and treatment compliance. In this dissertation, we focus on developing mathematical foundation and computational tools that extract and utilize personalized information to improve the decision-making process for physicians (and patients). We first focus on the management of diabetes mellitus and develop a pharmacokinetic and pharmacodynamics (PK/PD) drug effect model to characterize the personalized dose response of patients receiving anti-diabetic drug therapy. Such personalized information is then incorporated in a first-of-its-kind mixed-integer program to quantitatively optimize each patient’s dose regimen. In a retrospective study, the optimized regimen gives better glycemic control with less drug used than the original regimen prescribed. The second part of the thesis focuses on the optimization of external radiotherapy. We developed a multi-objective direct aperture model that optimizes clinical objectives based on their personalized clinical priorities. A heuristic column generation algorithm that does not require dose information is developed and greatly reduces the total solution time. Moreover, a mixed-integer beam selection model is incorporated into this model to produce plans with better dose distribution than those with beam manually selected by human planner.","abstract_has_math":false,"creators":["Wei, Xin"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Industrial and Systems Engineering","school":null,"contributors":[],"advisors":["Lee, Eva K."],"committee_chairs":[],"committee_members":["Romeijn, Edwin","Mei, Yajun","Sun, Andy","Quarshie, Alexander"],"year":2018,"date_issued":"2018-07-23","date_published":"2018-07-23","updated_at":"2026-11-19T04:09:36Z","subjects":["Personalized medicine","Diabetes","PK/PD","Radiotherapy","Direct aperture optimization"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/61652","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/61652","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F61652","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lee, Eva K."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Romeijn, Edwin","Mei, Yajun","Sun, Andy","Quarshie, Alexander"]},{"key":"dc:contributor.department","label":"Department","values":["Industrial and Systems Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["H. Milton Stewart School of Industrial and Systems Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Wei, Xin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-08-21T13:49:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-08-21T13:49:38Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-08"]},{"key":"dc:date.issued","label":"Date","values":["2018-07-23"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2018"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-08-21T13:49:38Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["29ad75f0-242d-49a7-9b3d-0ac88893323c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Personalized medicine","Diabetes","PK/PD","Radiotherapy","Direct aperture optimization"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/61652"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["One of the challenges in medical decision making is the complexity, variability and uncertainty that exist in both patients and different treatment methods. In real practice, patients are different in their personal characteristics, drug response and treatment compliance. In this dissertation, we focus on developing mathematical foundation and computational tools that extract and utilize personalized information to improve the decision-making process for physicians (and patients). We first focus on the management of diabetes mellitus and develop a pharmacokinetic and pharmacodynamics (PK/PD) drug effect model to characterize the personalized dose response of patients receiving anti-diabetic drug therapy. Such personalized information is then incorporated in a first-of-its-kind mixed-integer program to quantitatively optimize each patient’s dose regimen. In a retrospective study, the optimized regimen gives better glycemic control with less drug used than the original regimen prescribed. The second part of the thesis focuses on the optimization of external radiotherapy. We developed a multi-objective direct aperture model that optimizes clinical objectives based on their personalized clinical priorities. A heuristic column generation algorithm that does not require dose information is developed and greatly reduces the total solution time. Moreover, a mixed-integer beam selection model is incorporated into this model to produce plans with better dose distribution than those with beam manually selected by human planner."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Medical decision making - a personalized approach"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lee, Eva K."],"dc:contributor.committeemember":["Romeijn, Edwin","Mei, Yajun","Sun, Andy","Quarshie, Alexander"],"dc:contributor.department":["Industrial and Systems Engineering"],"dc:contributor.other":["H. Milton Stewart School of Industrial and Systems Engineering","College of Engineering"],"dc:creator":["Wei, Xin"],"dc:date.accessioned":["2019-08-21T13:49:38Z"],"dc:date.available":["2019-08-21T13:49:38Z"],"dc:date.created":["2018-08"],"dc:date.issued":["2018-07-23"],"dc:date.submitted":["August 2018"],"dc:date.updated":["2019-08-21T13:49:38Z"],"dc:description.abstract":["One of the challenges in medical decision making is the complexity, variability and uncertainty that exist in both patients and different treatment methods. In real practice, patients are different in their personal characteristics, drug response and treatment compliance. In this dissertation, we focus on developing mathematical foundation and computational tools that extract and utilize personalized information to improve the decision-making process for physicians (and patients). We first focus on the management of diabetes mellitus and develop a pharmacokinetic and pharmacodynamics (PK/PD) drug effect model to characterize the personalized dose response of patients receiving anti-diabetic drug therapy. Such personalized information is then incorporated in a first-of-its-kind mixed-integer program to quantitatively optimize each patient’s dose regimen. In a retrospective study, the optimized regimen gives better glycemic control with less drug used than the original regimen prescribed. The second part of the thesis focuses on the optimization of external radiotherapy. We developed a multi-objective direct aperture model that optimizes clinical objectives based on their personalized clinical priorities. A heuristic column generation algorithm that does not require dose information is developed and greatly reduces the total solution time. Moreover, a mixed-integer beam selection model is incorporated into this model to produce plans with better dose distribution than those with beam manually selected by human planner."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/61652"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.orgunit":["29ad75f0-242d-49a7-9b3d-0ac88893323c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Personalized medicine","Diabetes","PK/PD","Radiotherapy","Direct aperture optimization"],"dc:title":["Medical decision making - a personalized approach"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T04:09:36Z"}