{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/61724"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/61724","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Control of data center cooling using data driven heuristic approach","abstract":"This thesis proposes a method of heuristic temperature prediction with real-time data to control the cooling infrastructure of a data center. This thesis addresses thermal management in data centers through the control scheme in one case study, in which dynamic control of the air conditioner temperature set point with heuristic temperature prediction of the server rack inlet temperature results in reaching a target server rack temperature in ~30 min. This thesis addresses energy savings through another case study, in which dynamic controls utilize outside air economization, resulting in energy reduction of ~1-2 kW while reducing space temperature variation to under 2°C during normal operation.","abstract_html":"This thesis proposes a method of heuristic temperature prediction with real-time data to control the cooling infrastructure of a data center. This thesis addresses thermal management in data centers through the control scheme in one case study, in which dynamic control of the air conditioner temperature set point with heuristic temperature prediction of the server rack inlet temperature results in reaching a target server rack temperature in ~30 min. This thesis addresses energy savings through another case study, in which dynamic controls utilize outside air economization, resulting in energy reduction of ~1-2 kW while reducing space temperature variation to under 2°C during normal operation.","abstract_has_math":false,"creators":["Baxendale, Mitchell David"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Joshi, Yogendra"],"committee_chairs":[],"committee_members":["Yoda, Minami","Loutzenhiser, Peter"],"year":2019,"date_issued":"2019-05-21","date_published":"2019-05-21","updated_at":"2026-11-19T05:05:22Z","subjects":["Data center","Smart cooling","Economization","Energy efficiency","Thermal management","Data-driven modeling","Temperature prediction","Building management system","Computer room air conditioning","PI system","MATLAB"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/61724","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/61724","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F61724","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Joshi, Yogendra"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Yoda, Minami","Loutzenhiser, Peter"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Baxendale, Mitchell David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-08-21T13:52:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-08-21T13:52:02Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-08"]},{"key":"dc:date.issued","label":"Date","values":["2019-05-21"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2019"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-08-21T13:52:02Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["63ef328b-076b-44b7-92a9-0f7dd03fa1fa"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Data center","Smart cooling","Economization","Energy efficiency","Thermal management","Data-driven modeling","Temperature prediction","Building management system","Computer room air conditioning","PI system","MATLAB"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/61724"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis proposes a method of heuristic temperature prediction with real-time data to control the cooling infrastructure of a data center. This thesis addresses thermal management in data centers through the control scheme in one case study, in which dynamic control of the air conditioner temperature set point with heuristic temperature prediction of the server rack inlet temperature results in reaching a target server rack temperature in ~30 min. This thesis addresses energy savings through another case study, in which dynamic controls utilize outside air economization, resulting in energy reduction of ~1-2 kW while reducing space temperature variation to under 2°C during normal operation."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Control of data center cooling using data driven heuristic approach"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Joshi, Yogendra"],"dc:contributor.committeemember":["Yoda, Minami","Loutzenhiser, Peter"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Baxendale, Mitchell David"],"dc:date.accessioned":["2019-08-21T13:52:02Z"],"dc:date.available":["2019-08-21T13:52:02Z"],"dc:date.created":["2019-08"],"dc:date.issued":["2019-05-21"],"dc:date.submitted":["August 2019"],"dc:date.updated":["2019-08-21T13:52:02Z"],"dc:description.abstract":["This thesis proposes a method of heuristic temperature prediction with real-time data to control the cooling infrastructure of a data center. This thesis addresses thermal management in data centers through the control scheme in one case study, in which dynamic control of the air conditioner temperature set point with heuristic temperature prediction of the server rack inlet temperature results in reaching a target server rack temperature in ~30 min. This thesis addresses energy savings through another case study, in which dynamic controls utilize outside air economization, resulting in energy reduction of ~1-2 kW while reducing space temperature variation to under 2°C during normal operation."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/61724"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["63ef328b-076b-44b7-92a9-0f7dd03fa1fa"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Data center","Smart cooling","Economization","Energy efficiency","Thermal management","Data-driven modeling","Temperature prediction","Building management system","Computer room air conditioning","PI system","MATLAB"],"dc:title":["Control of data center cooling using data driven heuristic approach"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:05:22Z"}