{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/62799"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/62799","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Electronic antibody microarrays for label-free cell immunophenotyping","abstract":"Immunophenotyping (i.e., identifying cell membrane antigens) is widely used to characterize cell populations in basic research and to diagnose diseases from surface biomarkers in the clinic. This process usually requires complex instruments such as flow cytometers or fluorescence microscopes, which are typically housed in centralized laboratories. Microfluidic devices can be used as immunophenotyping assays through immunoaffinity-based capture of the target cells, and are able to analyze a limited-volume sample in a small-footprint, with the ultimate goal of replacing the need for centralized laboratories. However, microfluidic devices are typically designed for qualitative analysis, and almost always require external tools for the readout, which negates the cost and portability benefits of the chip itself. In the thesis, we introduce a microfluidic technology that employs a network of integrated electrical sensors to identify cell subpopulations based on their membrane antigens in a quantitative manner. To realize this technology, we develop a scalable electronic sensor network called microfluidic CODES (microfluidic coded orthogonal detection by electrical sensing), which combines code division multiple access (CDMA), a spread spectrum telecommunications technique, with Coulter sensing for the distributed detection of cells at strategic nodes across the microfluidic device from a single electrical output. By integrating the Microfluidic CODES technique with microfluidic cell capture chambers pre-functionalized with antibodies against target antigens, the device will achieve all-electronic cell immunophenotyping through the combinatorial arrangement of antibody sequences along microfluidic paths. Our technology will not only provide an integrated platform for label-free combinatorial immunophenotyping of cell populations against multiple antigen targets, but also be built on affordable hardware well suited for resource limited settings or point-of-care applications.","abstract_html":"Immunophenotyping (i.e., identifying cell membrane antigens) is widely used to characterize cell populations in basic research and to diagnose diseases from surface biomarkers in the clinic. This process usually requires complex instruments such as flow cytometers or fluorescence microscopes, which are typically housed in centralized laboratories. Microfluidic devices can be used as immunophenotyping assays through immunoaffinity-based capture of the target cells, and are able to analyze a limited-volume sample in a small-footprint, with the ultimate goal of replacing the need for centralized laboratories. However, microfluidic devices are typically designed for qualitative analysis, and almost always require external tools for the readout, which negates the cost and portability benefits of the chip itself. In the thesis, we introduce a microfluidic technology that employs a network of integrated electrical sensors to identify cell subpopulations based on their membrane antigens in a quantitative manner. To realize this technology, we develop a scalable electronic sensor network called microfluidic CODES (microfluidic coded orthogonal detection by electrical sensing), which combines code division multiple access (CDMA), a spread spectrum telecommunications technique, with Coulter sensing for the distributed detection of cells at strategic nodes across the microfluidic device from a single electrical output. By integrating the Microfluidic CODES technique with microfluidic cell capture chambers pre-functionalized with antibodies against target antigens, the device will achieve all-electronic cell immunophenotyping through the combinatorial arrangement of antibody sequences along microfluidic paths. Our technology will not only provide an integrated platform for label-free combinatorial immunophenotyping of cell populations against multiple antigen targets, but also be built on affordable hardware well suited for resource limited settings or point-of-care applications.","abstract_has_math":false,"creators":["Liu, Ruxiu"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Sarioglu, A. Fatih"],"committee_chairs":[],"committee_members":["Frazier, Albert B.","García, Andrés","Inan, Omer","Lam, Wilbur"],"year":2020,"date_issued":"2020-04-25","date_published":"2020-04-25","updated_at":"2026-11-19T06:07:38Z","subjects":["Microfluidics","Lab-on-a-chip","Immunophenotyping","Flow cytometry","Microfluidic CODES"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/62799","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/62799","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F62799","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sarioglu, A. Fatih"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Frazier, Albert B.","García, Andrés","Inan, Omer","Lam, Wilbur"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Liu, Ruxiu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-05-20T17:01:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-05-20T17:01:11Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-05"]},{"key":"dc:date.issued","label":"Date","values":["2020-04-25"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2020"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2020-05-20T17:01:11Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["a663fb68-17d4-4b9e-9342-a9fde343991e"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Bioengineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["5db25cda-aa52-48d2-8f63-c551ef2c92f4"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microfluidics","Lab-on-a-chip","Immunophenotyping","Flow cytometry","Microfluidic CODES"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/62799"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Immunophenotyping (i.e., identifying cell membrane antigens) is widely used to characterize cell populations in basic research and to diagnose diseases from surface biomarkers in the clinic. This process usually requires complex instruments such as flow cytometers or fluorescence microscopes, which are typically housed in centralized laboratories. Microfluidic devices can be used as immunophenotyping assays through immunoaffinity-based capture of the target cells, and are able to analyze a limited-volume sample in a small-footprint, with the ultimate goal of replacing the need for centralized laboratories. However, microfluidic devices are typically designed for qualitative analysis, and almost always require external tools for the readout, which negates the cost and portability benefits of the chip itself. In the thesis, we introduce a microfluidic technology that employs a network of integrated electrical sensors to identify cell subpopulations based on their membrane antigens in a quantitative manner. To realize this technology, we develop a scalable electronic sensor network called microfluidic CODES (microfluidic coded orthogonal detection by electrical sensing), which combines code division multiple access (CDMA), a spread spectrum telecommunications technique, with Coulter sensing for the distributed detection of cells at strategic nodes across the microfluidic device from a single electrical output. By integrating the Microfluidic CODES technique with microfluidic cell capture chambers pre-functionalized with antibodies against target antigens, the device will achieve all-electronic cell immunophenotyping through the combinatorial arrangement of antibody sequences along microfluidic paths. Our technology will not only provide an integrated platform for label-free combinatorial immunophenotyping of cell populations against multiple antigen targets, but also be built on affordable hardware well suited for resource limited settings or point-of-care applications."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Electronic antibody microarrays for label-free cell immunophenotyping"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sarioglu, A. Fatih"],"dc:contributor.committeemember":["Frazier, Albert B.","García, Andrés","Inan, Omer","Lam, Wilbur"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Liu, Ruxiu"],"dc:date.accessioned":["2020-05-20T17:01:11Z"],"dc:date.available":["2020-05-20T17:01:11Z"],"dc:date.created":["2020-05"],"dc:date.issued":["2020-04-25"],"dc:date.submitted":["May 2020"],"dc:date.updated":["2020-05-20T17:01:11Z"],"dc:description.abstract":["Immunophenotyping (i.e., identifying cell membrane antigens) is widely used to characterize cell populations in basic research and to diagnose diseases from surface biomarkers in the clinic. This process usually requires complex instruments such as flow cytometers or fluorescence microscopes, which are typically housed in centralized laboratories. Microfluidic devices can be used as immunophenotyping assays through immunoaffinity-based capture of the target cells, and are able to analyze a limited-volume sample in a small-footprint, with the ultimate goal of replacing the need for centralized laboratories. However, microfluidic devices are typically designed for qualitative analysis, and almost always require external tools for the readout, which negates the cost and portability benefits of the chip itself. In the thesis, we introduce a microfluidic technology that employs a network of integrated electrical sensors to identify cell subpopulations based on their membrane antigens in a quantitative manner. To realize this technology, we develop a scalable electronic sensor network called microfluidic CODES (microfluidic coded orthogonal detection by electrical sensing), which combines code division multiple access (CDMA), a spread spectrum telecommunications technique, with Coulter sensing for the distributed detection of cells at strategic nodes across the microfluidic device from a single electrical output. By integrating the Microfluidic CODES technique with microfluidic cell capture chambers pre-functionalized with antibodies against target antigens, the device will achieve all-electronic cell immunophenotyping through the combinatorial arrangement of antibody sequences along microfluidic paths. Our technology will not only provide an integrated platform for label-free combinatorial immunophenotyping of cell populations against multiple antigen targets, but also be built on affordable hardware well suited for resource limited settings or point-of-care applications."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/62799"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["a663fb68-17d4-4b9e-9342-a9fde343991e"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Bioengineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["5db25cda-aa52-48d2-8f63-c551ef2c92f4"],"dc:subject":["Microfluidics","Lab-on-a-chip","Immunophenotyping","Flow cytometry","Microfluidic CODES"],"dc:title":["Electronic antibody microarrays for label-free cell immunophenotyping"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T06:07:38Z"}