{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/63531"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/63531","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Mechanobiological regulation of early stage bone repair","abstract":"Each year in the United States alone, several hundred thousand people suffer skeletal fractures that do not heal from the original treatment, resulting in non-union. To improve patient outcomes, there is a clinical need for therapeutic strategies that stimulate bone repair. The skeleton dynamically adapts its structure and composition to mechanical loads, and controlled loading via rehabilitation represents a non-pharmacologic target with the potential to stimulate endogenous bone regeneration. The primary objectives of this thesis were to develop technical approaches to longitudinally monitor dynamic mechanical cues during bone healing and elucidate how specific magnitudes promote repair. Our overall hypothesis was that moderate mechanical stimulation exerted via periodic walking could enhance bone regeneration. To test this hypothesis, we engineered a fully implantable wireless strain sensor platform that enabled real-time non-invasive monitoring of mechanical cues in a pre-clinical model of skeletal repair. We discovered that early-stage strain magnitudes correlated with significantly improved healing outcomes. We also observed that osteogenic mechanical loading exerted effects on early stage biological processes that precede mineralization, including immune cytokine signaling and angiogenesis. At the conclusion of the experiments, we attained a deeper understanding of how specific mechanical cues regulate bone repair, and established a novel sensor platform to further investigate mechanobiology. The knowledge gained by this thesis aids the development of integrative therapeutic strategies that stimulate bone repair via functional rehabilitation. In addition, the technological outcomes of this thesis serve as foundational support for the expanded development of implantable medical sensor technologies with broad implications to enhance diagnostics, therapeutic development, and interventional surveillance.","abstract_html":"Each year in the United States alone, several hundred thousand people suffer skeletal fractures that do not heal from the original treatment, resulting in non-union. To improve patient outcomes, there is a clinical need for therapeutic strategies that stimulate bone repair. The skeleton dynamically adapts its structure and composition to mechanical loads, and controlled loading via rehabilitation represents a non-pharmacologic target with the potential to stimulate endogenous bone regeneration. The primary objectives of this thesis were to develop technical approaches to longitudinally monitor dynamic mechanical cues during bone healing and elucidate how specific magnitudes promote repair. Our overall hypothesis was that moderate mechanical stimulation exerted via periodic walking could enhance bone regeneration. To test this hypothesis, we engineered a fully implantable wireless strain sensor platform that enabled real-time non-invasive monitoring of mechanical cues in a pre-clinical model of skeletal repair. We discovered that early-stage strain magnitudes correlated with significantly improved healing outcomes. We also observed that osteogenic mechanical loading exerted effects on early stage biological processes that precede mineralization, including immune cytokine signaling and angiogenesis. At the conclusion of the experiments, we attained a deeper understanding of how specific mechanical cues regulate bone repair, and established a novel sensor platform to further investigate mechanobiology. The knowledge gained by this thesis aids the development of integrative therapeutic strategies that stimulate bone repair via functional rehabilitation. In addition, the technological outcomes of this thesis serve as foundational support for the expanded development of implantable medical sensor technologies with broad implications to enhance diagnostics, therapeutic development, and interventional surveillance.","abstract_has_math":false,"creators":["Klosterhoff, Brett S."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Guldberg, Robert E.","Willett, Nick J."],"committee_chairs":[],"committee_members":["Botchwey, Edward A.","Ong, Keat Ghee","Hollister, Scott J.","Weiss, Jeffrey A."],"year":2019,"date_issued":"2019-07-02","date_published":"2019-07-02","updated_at":"2026-11-19T05:59:24Z","subjects":["Bone regeneration","Biomedical sensors","Mechanobiology","Rehabilitation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/63531","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/63531","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F63531","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Guldberg, Robert E.","Willett, Nick J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Botchwey, Edward A.","Ong, Keat Ghee","Hollister, Scott J.","Weiss, Jeffrey A."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Klosterhoff, Brett S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-09-08T12:40:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-09-08T12:40:59Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-08"]},{"key":"dc:date.issued","label":"Date","values":["2019-07-02"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2019"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2020-09-08T12:40:59Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["5de086eb-63e8-46e3-b1cc-3569bb13e59c"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Bioengineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["5db25cda-aa52-48d2-8f63-c551ef2c92f4"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bone regeneration","Biomedical sensors","Mechanobiology","Rehabilitation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/63531"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Each year in the United States alone, several hundred thousand people suffer skeletal fractures that do not heal from the original treatment, resulting in non-union. To improve patient outcomes, there is a clinical need for therapeutic strategies that stimulate bone repair. The skeleton dynamically adapts its structure and composition to mechanical loads, and controlled loading via rehabilitation represents a non-pharmacologic target with the potential to stimulate endogenous bone regeneration. The primary objectives of this thesis were to develop technical approaches to longitudinally monitor dynamic mechanical cues during bone healing and elucidate how specific magnitudes promote repair. Our overall hypothesis was that moderate mechanical stimulation exerted via periodic walking could enhance bone regeneration. To test this hypothesis, we engineered a fully implantable wireless strain sensor platform that enabled real-time non-invasive monitoring of mechanical cues in a pre-clinical model of skeletal repair. We discovered that early-stage strain magnitudes correlated with significantly improved healing outcomes. We also observed that osteogenic mechanical loading exerted effects on early stage biological processes that precede mineralization, including immune cytokine signaling and angiogenesis. At the conclusion of the experiments, we attained a deeper understanding of how specific mechanical cues regulate bone repair, and established a novel sensor platform to further investigate mechanobiology. The knowledge gained by this thesis aids the development of integrative therapeutic strategies that stimulate bone repair via functional rehabilitation. In addition, the technological outcomes of this thesis serve as foundational support for the expanded development of implantable medical sensor technologies with broad implications to enhance diagnostics, therapeutic development, and interventional surveillance."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Mechanobiological regulation of early stage bone repair"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Guldberg, Robert E.","Willett, Nick J."],"dc:contributor.committeemember":["Botchwey, Edward A.","Ong, Keat Ghee","Hollister, Scott J.","Weiss, Jeffrey A."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Klosterhoff, Brett S."],"dc:date.accessioned":["2020-09-08T12:40:59Z"],"dc:date.available":["2020-09-08T12:40:59Z"],"dc:date.created":["2019-08"],"dc:date.issued":["2019-07-02"],"dc:date.submitted":["August 2019"],"dc:date.updated":["2020-09-08T12:40:59Z"],"dc:description.abstract":["Each year in the United States alone, several hundred thousand people suffer skeletal fractures that do not heal from the original treatment, resulting in non-union. To improve patient outcomes, there is a clinical need for therapeutic strategies that stimulate bone repair. The skeleton dynamically adapts its structure and composition to mechanical loads, and controlled loading via rehabilitation represents a non-pharmacologic target with the potential to stimulate endogenous bone regeneration. The primary objectives of this thesis were to develop technical approaches to longitudinally monitor dynamic mechanical cues during bone healing and elucidate how specific magnitudes promote repair. Our overall hypothesis was that moderate mechanical stimulation exerted via periodic walking could enhance bone regeneration. To test this hypothesis, we engineered a fully implantable wireless strain sensor platform that enabled real-time non-invasive monitoring of mechanical cues in a pre-clinical model of skeletal repair. We discovered that early-stage strain magnitudes correlated with significantly improved healing outcomes. We also observed that osteogenic mechanical loading exerted effects on early stage biological processes that precede mineralization, including immune cytokine signaling and angiogenesis. At the conclusion of the experiments, we attained a deeper understanding of how specific mechanical cues regulate bone repair, and established a novel sensor platform to further investigate mechanobiology. The knowledge gained by this thesis aids the development of integrative therapeutic strategies that stimulate bone repair via functional rehabilitation. In addition, the technological outcomes of this thesis serve as foundational support for the expanded development of implantable medical sensor technologies with broad implications to enhance diagnostics, therapeutic development, and interventional surveillance."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/63531"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["5de086eb-63e8-46e3-b1cc-3569bb13e59c"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Bioengineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["5db25cda-aa52-48d2-8f63-c551ef2c92f4"],"dc:subject":["Bone regeneration","Biomedical sensors","Mechanobiology","Rehabilitation"],"dc:title":["Mechanobiological regulation of early stage bone repair"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:59:24Z"}