{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/63638"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/63638","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Optimization of residential microgrids using black-box modeling methods","abstract":"The optimization of a residential microgrid to respond to demand response signals that increase the dispatchability of locally generated solar photovoltaic (PV) energy while reducing total energy cost is investigated. The study is conducted using data gathered from a 62-home neighborhood located in Birmingham, AL. The HVAC system and water heater, which are the most significant residential electric loads, are designated as the controllable loads in this study. A comparison of system identification method accuracy for the HVAC and water heating systems is made between black-box models and grey-box models found in the literature. A multi-objective optimization problem is then developed with the objectives of minimizing energy cost and consumption while maximizing thermal comfort and the consumption of locally generated PV energy. Results show a maximum total energy savings of 12.9%, a maximum peak energy reduction of 41.3%, and a maximum total cost reduction of 16.6%.","abstract_html":"The optimization of a residential microgrid to respond to demand response signals that increase the dispatchability of locally generated solar photovoltaic (PV) energy while reducing total energy cost is investigated. The study is conducted using data gathered from a 62-home neighborhood located in Birmingham, AL. The HVAC system and water heater, which are the most significant residential electric loads, are designated as the controllable loads in this study. A comparison of system identification method accuracy for the HVAC and water heating systems is made between black-box models and grey-box models found in the literature. A multi-objective optimization problem is then developed with the objectives of minimizing energy cost and consumption while maximizing thermal comfort and the consumption of locally generated PV energy. Results show a maximum total energy savings of 12.9%, a maximum peak energy reduction of 41.3%, and a maximum total cost reduction of 16.6%.","abstract_has_math":false,"creators":["Green, Christy"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Garimella, Srinivas"],"committee_chairs":[],"committee_members":["Bras, Berdinus","Simmons, Richard"],"year":2020,"date_issued":"2020-07-06","date_published":"2020-07-06","updated_at":"2026-11-19T06:13:23Z","subjects":["Energy optimization","Black-box model","Data-driven model","Machine learning","Demand response","Residential microgrid"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/63638","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/63638","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F63638","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Garimella, Srinivas"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bras, Berdinus","Simmons, Richard"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Green, Christy"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-09-08T12:47:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-09-08T12:47:03Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-08"]},{"key":"dc:date.issued","label":"Date","values":["2020-07-06"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2020"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2020-09-08T12:47:03Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["7c74399b-6962-4814-9d2a-51f8b9c41e1f"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Energy optimization","Black-box model","Data-driven model","Machine learning","Demand response","Residential microgrid"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/63638"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The optimization of a residential microgrid to respond to demand response signals that increase the dispatchability of locally generated solar photovoltaic (PV) energy while reducing total energy cost is investigated. The study is conducted using data gathered from a 62-home neighborhood located in Birmingham, AL. The HVAC system and water heater, which are the most significant residential electric loads, are designated as the controllable loads in this study. A comparison of system identification method accuracy for the HVAC and water heating systems is made between black-box models and grey-box models found in the literature. A multi-objective optimization problem is then developed with the objectives of minimizing energy cost and consumption while maximizing thermal comfort and the consumption of locally generated PV energy. Results show a maximum total energy savings of 12.9%, a maximum peak energy reduction of 41.3%, and a maximum total cost reduction of 16.6%."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Optimization of residential microgrids using black-box modeling methods"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Garimella, Srinivas"],"dc:contributor.committeemember":["Bras, Berdinus","Simmons, Richard"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Green, Christy"],"dc:date.accessioned":["2020-09-08T12:47:03Z"],"dc:date.available":["2020-09-08T12:47:03Z"],"dc:date.created":["2020-08"],"dc:date.issued":["2020-07-06"],"dc:date.submitted":["August 2020"],"dc:date.updated":["2020-09-08T12:47:03Z"],"dc:description.abstract":["The optimization of a residential microgrid to respond to demand response signals that increase the dispatchability of locally generated solar photovoltaic (PV) energy while reducing total energy cost is investigated. The study is conducted using data gathered from a 62-home neighborhood located in Birmingham, AL. The HVAC system and water heater, which are the most significant residential electric loads, are designated as the controllable loads in this study. A comparison of system identification method accuracy for the HVAC and water heating systems is made between black-box models and grey-box models found in the literature. A multi-objective optimization problem is then developed with the objectives of minimizing energy cost and consumption while maximizing thermal comfort and the consumption of locally generated PV energy. Results show a maximum total energy savings of 12.9%, a maximum peak energy reduction of 41.3%, and a maximum total cost reduction of 16.6%."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/63638"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["7c74399b-6962-4814-9d2a-51f8b9c41e1f"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Energy optimization","Black-box model","Data-driven model","Machine learning","Demand response","Residential microgrid"],"dc:title":["Optimization of residential microgrids using black-box modeling methods"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T06:13:23Z"}