{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/63640"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/63640","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Characterization of algorithms and performance of a fine-resolution active interrogation system","abstract":"Active interrogation is a crucial tool in modern applications of nonintrusive assay: x- and gamma-ray interrogation systems are commonly employed in cargo inspection as well as in medical imaging, among other applications. In this work, a novel linear imaging array is characterized, and reconstruction algorithm developed, for active interrogation. The system consists of lutetium-yttrium oxyorthosilicate (LYSO) scintillator crystals in small form factor, as well as fused silica quartz elements, employed as a radiation-detecting scintillator and Cerenkov radiator, respectively. Cerenkov radiators here represent a low-cost alternative to scintillators for conversion of radiation to optical photons. Silicon photomultipliers (SiPMs) are used for optical light readout. Challenges associated with imaging using disparate detector element types are discussed, and performance results from ANSI-like imaging tests are presented. The system achieves good spatial resolution (within 4 mm) and is capable of detection of at least 12 AWG wire. Contrast sensitivity is at most 2% under the described test conditions.","abstract_html":"Active interrogation is a crucial tool in modern applications of nonintrusive assay: x- and gamma-ray interrogation systems are commonly employed in cargo inspection as well as in medical imaging, among other applications. In this work, a novel linear imaging array is characterized, and reconstruction algorithm developed, for active interrogation. The system consists of lutetium-yttrium oxyorthosilicate (LYSO) scintillator crystals in small form factor, as well as fused silica quartz elements, employed as a radiation-detecting scintillator and Cerenkov radiator, respectively. Cerenkov radiators here represent a low-cost alternative to scintillators for conversion of radiation to optical photons. Silicon photomultipliers (SiPMs) are used for optical light readout. Challenges associated with imaging using disparate detector element types are discussed, and performance results from ANSI-like imaging tests are presented. The system achieves good spatial resolution (within 4 mm) and is capable of detection of at least 12 AWG wire. Contrast sensitivity is at most 2% under the described test conditions.","abstract_has_math":false,"creators":["Maloney, Luke J."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Erickson, Anna S."],"committee_chairs":[],"committee_members":["Hertel, Nolan","Biegalski, Steven","Wang, C.-K. Chris","Zhang, Rongxiao","Rose, Paul B."],"year":2020,"date_issued":"2020-07-06","date_published":"2020-07-06","updated_at":"2026-11-19T05:15:02Z","subjects":["Cerenkov radiator","Active interrogation","Silicon photomultiplier","Fine resolution"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/63640","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/63640","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F63640","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Erickson, Anna S."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hertel, Nolan","Biegalski, Steven","Wang, C.-K. Chris","Zhang, Rongxiao","Rose, Paul B."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Maloney, Luke J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-09-08T12:47:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-09-08T12:47:06Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-08"]},{"key":"dc:date.issued","label":"Date","values":["2020-07-06"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2020"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2020-09-08T12:47:06Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["df2e2349-4cf3-4d53-89e5-adc9b56c9ac6"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cerenkov radiator","Active interrogation","Silicon photomultiplier","Fine resolution"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/63640"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Active interrogation is a crucial tool in modern applications of nonintrusive assay: x- and gamma-ray interrogation systems are commonly employed in cargo inspection as well as in medical imaging, among other applications. In this work, a novel linear imaging array is characterized, and reconstruction algorithm developed, for active interrogation. The system consists of lutetium-yttrium oxyorthosilicate (LYSO) scintillator crystals in small form factor, as well as fused silica quartz elements, employed as a radiation-detecting scintillator and Cerenkov radiator, respectively. Cerenkov radiators here represent a low-cost alternative to scintillators for conversion of radiation to optical photons. Silicon photomultipliers (SiPMs) are used for optical light readout. Challenges associated with imaging using disparate detector element types are discussed, and performance results from ANSI-like imaging tests are presented. The system achieves good spatial resolution (within 4 mm) and is capable of detection of at least 12 AWG wire. Contrast sensitivity is at most 2% under the described test conditions."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization of algorithms and performance of a fine-resolution active interrogation system"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Erickson, Anna S."],"dc:contributor.committeemember":["Hertel, Nolan","Biegalski, Steven","Wang, C.-K. Chris","Zhang, Rongxiao","Rose, Paul B."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Maloney, Luke J."],"dc:date.accessioned":["2020-09-08T12:47:06Z"],"dc:date.available":["2020-09-08T12:47:06Z"],"dc:date.created":["2020-08"],"dc:date.issued":["2020-07-06"],"dc:date.submitted":["August 2020"],"dc:date.updated":["2020-09-08T12:47:06Z"],"dc:description.abstract":["Active interrogation is a crucial tool in modern applications of nonintrusive assay: x- and gamma-ray interrogation systems are commonly employed in cargo inspection as well as in medical imaging, among other applications. In this work, a novel linear imaging array is characterized, and reconstruction algorithm developed, for active interrogation. The system consists of lutetium-yttrium oxyorthosilicate (LYSO) scintillator crystals in small form factor, as well as fused silica quartz elements, employed as a radiation-detecting scintillator and Cerenkov radiator, respectively. Cerenkov radiators here represent a low-cost alternative to scintillators for conversion of radiation to optical photons. Silicon photomultipliers (SiPMs) are used for optical light readout. Challenges associated with imaging using disparate detector element types are discussed, and performance results from ANSI-like imaging tests are presented. The system achieves good spatial resolution (within 4 mm) and is capable of detection of at least 12 AWG wire. Contrast sensitivity is at most 2% under the described test conditions."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/63640"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["df2e2349-4cf3-4d53-89e5-adc9b56c9ac6"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Nuclear Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"],"dc:subject":["Cerenkov radiator","Active interrogation","Silicon photomultiplier","Fine resolution"],"dc:title":["Characterization of algorithms and performance of a fine-resolution active interrogation system"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:15:02Z"}