{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/64013"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/64013","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Single-chip reduced-wire active catheter system with programmable transmit beamforming and receive time-division multiplexing for intracardiac echocardiography","abstract":"A single chip reduced-wire active catheter system, which adopts programmable transmit beamforming and receive time-division multiplexing (TDM) was proposed. The front-end application-specific integrated circuit (ASIC) is designed for driving a 64-channel 1-D piezo-transducer array or capacitive micromachined ultrasound transducer (CMUT) array in intracardiac echocardiography (ICE) catheters. ICE has become more important clinical modality in interventional ultrasound imaging. It provides real-time ultrasound imaging, guiding interventions like valve repair, placement of stents, closure of atrial septal defects (ASD) and catheter-based ablation to treat atrial fibrillation. Current ICE catheters offer a limited 2-D or 3-D field of view in spite of large number electrical interconnections to the main imaging system, which are mainly determined by the number of array elements and ground connections. In order to use ICE catheters under MRI instead of the ionizing X-ray radiation-based angiography, the number of interconnect wires in the catheter should be minimized to reduce RF-induced heating from metal connection. Furthermore, reducing the number of wires would improve the flexibility, reach, and even lower the cost of the single-use ICE catheters. Therefore, an interconnection reduction method which integrates electronics in the catheter tip would have a significant impact in the catheter-based ultrasound imaging applications.","abstract_html":"A single chip reduced-wire active catheter system, which adopts programmable transmit beamforming and receive time-division multiplexing (TDM) was proposed. The front-end application-specific integrated circuit (ASIC) is designed for driving a 64-channel 1-D piezo-transducer array or capacitive micromachined ultrasound transducer (CMUT) array in intracardiac echocardiography (ICE) catheters. ICE has become more important clinical modality in interventional ultrasound imaging. It provides real-time ultrasound imaging, guiding interventions like valve repair, placement of stents, closure of atrial septal defects (ASD) and catheter-based ablation to treat atrial fibrillation. Current ICE catheters offer a limited 2-D or 3-D field of view in spite of large number electrical interconnections to the main imaging system, which are mainly determined by the number of array elements and ground connections. In order to use ICE catheters under MRI instead of the ionizing X-ray radiation-based angiography, the number of interconnect wires in the catheter should be minimized to reduce RF-induced heating from metal connection. Furthermore, reducing the number of wires would improve the flexibility, reach, and even lower the cost of the single-use ICE catheters. Therefore, an interconnection reduction method which integrates electronics in the catheter tip would have a significant impact in the catheter-based ultrasound imaging applications.","abstract_has_math":false,"creators":["Jung, Gwangrok"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Degertekin, F. Levent"],"committee_chairs":[],"committee_members":["Tekes, Coskun","Ayazi, Farrokh","Inan, Omer T.","Emelianov, Stanislav","Degertekin, F. Levent"],"year":2019,"date_issued":"2019-08-19","date_published":"2019-08-19","updated_at":"2026-11-19T05:17:50Z","subjects":["Analog","Intracardiac echocardiography","Circuit","Beamformer","Pulser"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/64013","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/64013","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F64013","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Degertekin, F. Levent"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Tekes, Coskun","Ayazi, Farrokh","Inan, Omer T.","Emelianov, Stanislav","Degertekin, F. Levent"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Jung, Gwangrok"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-01-11T17:04:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-01-11T17:04:47Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-12"]},{"key":"dc:date.issued","label":"Date","values":["2019-08-19"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2019"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-01-11T17:04:48Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["9afd92fe-bb98-4c83-b8ac-fc596320991a"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Analog","Intracardiac echocardiography","Circuit","Beamformer","Pulser"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/64013"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A single chip reduced-wire active catheter system, which adopts programmable transmit beamforming and receive time-division multiplexing (TDM) was proposed. The front-end application-specific integrated circuit (ASIC) is designed for driving a 64-channel 1-D piezo-transducer array or capacitive micromachined ultrasound transducer (CMUT) array in intracardiac echocardiography (ICE) catheters. ICE has become more important clinical modality in interventional ultrasound imaging. It provides real-time ultrasound imaging, guiding interventions like valve repair, placement of stents, closure of atrial septal defects (ASD) and catheter-based ablation to treat atrial fibrillation. Current ICE catheters offer a limited 2-D or 3-D field of view in spite of large number electrical interconnections to the main imaging system, which are mainly determined by the number of array elements and ground connections. In order to use ICE catheters under MRI instead of the ionizing X-ray radiation-based angiography, the number of interconnect wires in the catheter should be minimized to reduce RF-induced heating from metal connection. Furthermore, reducing the number of wires would improve the flexibility, reach, and even lower the cost of the single-use ICE catheters. Therefore, an interconnection reduction method which integrates electronics in the catheter tip would have a significant impact in the catheter-based ultrasound imaging applications."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Single-chip reduced-wire active catheter system with programmable transmit beamforming and receive time-division multiplexing for intracardiac echocardiography"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Degertekin, F. Levent"],"dc:contributor.committeemember":["Tekes, Coskun","Ayazi, Farrokh","Inan, Omer T.","Emelianov, Stanislav","Degertekin, F. Levent"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Jung, Gwangrok"],"dc:date.accessioned":["2021-01-11T17:04:47Z"],"dc:date.available":["2021-01-11T17:04:47Z"],"dc:date.created":["2019-12"],"dc:date.issued":["2019-08-19"],"dc:date.submitted":["December 2019"],"dc:date.updated":["2021-01-11T17:04:48Z"],"dc:description.abstract":["A single chip reduced-wire active catheter system, which adopts programmable transmit beamforming and receive time-division multiplexing (TDM) was proposed. The front-end application-specific integrated circuit (ASIC) is designed for driving a 64-channel 1-D piezo-transducer array or capacitive micromachined ultrasound transducer (CMUT) array in intracardiac echocardiography (ICE) catheters. ICE has become more important clinical modality in interventional ultrasound imaging. It provides real-time ultrasound imaging, guiding interventions like valve repair, placement of stents, closure of atrial septal defects (ASD) and catheter-based ablation to treat atrial fibrillation. Current ICE catheters offer a limited 2-D or 3-D field of view in spite of large number electrical interconnections to the main imaging system, which are mainly determined by the number of array elements and ground connections. In order to use ICE catheters under MRI instead of the ionizing X-ray radiation-based angiography, the number of interconnect wires in the catheter should be minimized to reduce RF-induced heating from metal connection. Furthermore, reducing the number of wires would improve the flexibility, reach, and even lower the cost of the single-use ICE catheters. Therefore, an interconnection reduction method which integrates electronics in the catheter tip would have a significant impact in the catheter-based ultrasound imaging applications."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/64013"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["9afd92fe-bb98-4c83-b8ac-fc596320991a"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Analog","Intracardiac echocardiography","Circuit","Beamformer","Pulser"],"dc:title":["Single-chip reduced-wire active catheter system with programmable transmit beamforming and receive time-division multiplexing for intracardiac echocardiography"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:17:50Z"}