{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/64553"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/64553","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Noncontact Seismocardiogram Signal Detection Using Microwave Doppler Radar","abstract":"The objective of the research is to achieve non-contact detection of seismocardiogram (SCG), a representation of mechanical heart motion, using microwave Doppler radar system. The increase in demand for health monitoring requires robust, reliable, and accurate remote detection of cardiac signals. Due to its ability to penetrate non-metal obstacles, microwave Doppler radar is promising to provide a non-contact and unobtrusive measurement. In this dissertation, both the hardware system and the signal processing approaches are developed for providing an accurate and reliable measurement of cardiac signals using the microwave Doppler radar. First, a noise suppression scheme and a clutter removal strategy are investigated to improve the performance of a microwave Doppler radar system. Then, an investigation is conducted to demonstrate the effectiveness of using a radar signal to represent SCG, and a standalone method is developed to extract the SCG features from the radar signal without using a contact electrocardiogram (ECG) signal that the conventional methods rely on. With the development of the hardware system and signal processing approaches, the complete non-contact measurement and analysis of cardiac signals can be achieved.","abstract_html":"The objective of the research is to achieve non-contact detection of seismocardiogram (SCG), a representation of mechanical heart motion, using microwave Doppler radar system. The increase in demand for health monitoring requires robust, reliable, and accurate remote detection of cardiac signals. Due to its ability to penetrate non-metal obstacles, microwave Doppler radar is promising to provide a non-contact and unobtrusive measurement. In this dissertation, both the hardware system and the signal processing approaches are developed for providing an accurate and reliable measurement of cardiac signals using the microwave Doppler radar. First, a noise suppression scheme and a clutter removal strategy are investigated to improve the performance of a microwave Doppler radar system. Then, an investigation is conducted to demonstrate the effectiveness of using a radar signal to represent SCG, and a standalone method is developed to extract the SCG features from the radar signal without using a contact electrocardiogram (ECG) signal that the conventional methods rely on. With the development of the hardware system and signal processing approaches, the complete non-contact measurement and analysis of cardiac signals can be achieved.","abstract_has_math":false,"creators":["Xia, Zongyang"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Zhang, Ying"],"committee_chairs":[],"committee_members":["Durgin, Gregory David","Inan, Omer T.","Peterson, Andrew F.","Wang, Yang"],"year":2020,"date_issued":"2020-01-03","date_published":"2020-01-03","updated_at":"2026-11-19T05:15:14Z","subjects":["Seismocardiogram (SCG)","Microwave","Radar","Cardiac","Doppler effect","Remote sensing"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/64553","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/64553","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F64553","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhang, Ying"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Durgin, Gregory David","Inan, Omer T.","Peterson, Andrew F.","Wang, Yang"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Xia, Zongyang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-06-10T13:48:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-06-10T13:48:41Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-05"]},{"key":"dc:date.issued","label":"Date","values":["2020-01-03"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2020"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-06-10T13:48:41Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["c8db6e3e-6bee-4fa1-912c-f8f6817a96a3"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Seismocardiogram (SCG)","Microwave","Radar","Cardiac","Doppler effect","Remote sensing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/64553"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of the research is to achieve non-contact detection of seismocardiogram (SCG), a representation of mechanical heart motion, using microwave Doppler radar system. The increase in demand for health monitoring requires robust, reliable, and accurate remote detection of cardiac signals. Due to its ability to penetrate non-metal obstacles, microwave Doppler radar is promising to provide a non-contact and unobtrusive measurement. In this dissertation, both the hardware system and the signal processing approaches are developed for providing an accurate and reliable measurement of cardiac signals using the microwave Doppler radar. First, a noise suppression scheme and a clutter removal strategy are investigated to improve the performance of a microwave Doppler radar system. Then, an investigation is conducted to demonstrate the effectiveness of using a radar signal to represent SCG, and a standalone method is developed to extract the SCG features from the radar signal without using a contact electrocardiogram (ECG) signal that the conventional methods rely on. With the development of the hardware system and signal processing approaches, the complete non-contact measurement and analysis of cardiac signals can be achieved."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Noncontact Seismocardiogram Signal Detection Using Microwave Doppler Radar"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zhang, Ying"],"dc:contributor.committeemember":["Durgin, Gregory David","Inan, Omer T.","Peterson, Andrew F.","Wang, Yang"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Xia, Zongyang"],"dc:date.accessioned":["2021-06-10T13:48:41Z"],"dc:date.available":["2021-06-10T13:48:41Z"],"dc:date.created":["2020-05"],"dc:date.issued":["2020-01-03"],"dc:date.submitted":["May 2020"],"dc:date.updated":["2021-06-10T13:48:41Z"],"dc:description.abstract":["The objective of the research is to achieve non-contact detection of seismocardiogram (SCG), a representation of mechanical heart motion, using microwave Doppler radar system. The increase in demand for health monitoring requires robust, reliable, and accurate remote detection of cardiac signals. Due to its ability to penetrate non-metal obstacles, microwave Doppler radar is promising to provide a non-contact and unobtrusive measurement. In this dissertation, both the hardware system and the signal processing approaches are developed for providing an accurate and reliable measurement of cardiac signals using the microwave Doppler radar. First, a noise suppression scheme and a clutter removal strategy are investigated to improve the performance of a microwave Doppler radar system. Then, an investigation is conducted to demonstrate the effectiveness of using a radar signal to represent SCG, and a standalone method is developed to extract the SCG features from the radar signal without using a contact electrocardiogram (ECG) signal that the conventional methods rely on. With the development of the hardware system and signal processing approaches, the complete non-contact measurement and analysis of cardiac signals can be achieved."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/64553"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["c8db6e3e-6bee-4fa1-912c-f8f6817a96a3"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Seismocardiogram (SCG)","Microwave","Radar","Cardiac","Doppler effect","Remote sensing"],"dc:title":["Noncontact Seismocardiogram Signal Detection Using Microwave Doppler Radar"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:15:14Z"}