{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/64718"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/64718","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Improving Energy Efficiency and Productivity in Industrial Plants Using Dynamic Voltage Management","abstract":"Conservation voltage reduction (CVR) is an established practice of having the distribution system loads operate at the lower end of the accepted limits based on the standard ANSI C84.1 to provide reduction in power consumption. This standard stipulates optimal voltage levels where the customer equipment is expected to operate with normal performance. CVR has been implemented traditionally by utilities by controlling the voltage on a distribution circuit to the lower end of the tolerance band defined by this standard. The effects of conservation voltage reduction are quantified by a metric called CVR factor (CVR_f). Some references have pointed out that utilities may have a concern about potential reduction in revenue they might incur due to conservation voltage reduction. CVR factor on an average at the distribution feeder level has been discussed to be 0.8. This research investigates the mechanism of saving energy in industrial plants and suggests measures to quantify the CVR factor. The requirements of a device for voltage management are explained. The proposed solution employs coaxial winding transformers whose salient features have been discussed. Existing solutions may have significant issues. Their limited fault handling capability makes them less robust to handle the forces and this may lead to destruction of the equipment or they may experience other issues including sluggish response or low efficiency.","abstract_html":"Conservation voltage reduction (CVR) is an established practice of having the distribution system loads operate at the lower end of the accepted limits based on the standard ANSI C84.1 to provide reduction in power consumption. This standard stipulates optimal voltage levels where the customer equipment is expected to operate with normal performance. CVR has been implemented traditionally by utilities by controlling the voltage on a distribution circuit to the lower end of the tolerance band defined by this standard. The effects of conservation voltage reduction are quantified by a metric called CVR factor (CVR_f). Some references have pointed out that utilities may have a concern about potential reduction in revenue they might incur due to conservation voltage reduction. CVR factor on an average at the distribution feeder level has been discussed to be 0.8. This research investigates the mechanism of saving energy in industrial plants and suggests measures to quantify the CVR factor. The requirements of a device for voltage management are explained. The proposed solution employs coaxial winding transformers whose salient features have been discussed. Existing solutions may have significant issues. Their limited fault handling capability makes them less robust to handle the forces and this may lead to destruction of the equipment or they may experience other issues including sluggish response or low efficiency.","abstract_has_math":false,"creators":["Jayaraman, Sathish"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Divan, Deepakraj M."],"committee_chairs":[],"committee_members":["Habetler, Thomas","Saeedifard, Maryam","Brown, Marilyn","Klein, Benjamin"],"year":2021,"date_issued":"2021-03-23","date_published":"2021-03-23","updated_at":"2026-11-19T04:54:18Z","subjects":["Conservation voltage reduction (CVR), fault current and efficiency, industrial loads, voltage sag."],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/64718","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/64718","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F64718","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Divan, Deepakraj M."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Habetler, Thomas","Saeedifard, Maryam","Brown, Marilyn","Klein, Benjamin"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Jayaraman, Sathish"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-06-10T16:52:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-06-10T16:52:06Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-05"]},{"key":"dc:date.issued","label":"Date","values":["2021-03-23"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2021"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-06-10T16:52:06Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["db2b03a1-dd75-4a65-94bb-79e8197e26ea"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Conservation voltage reduction (CVR), fault current and efficiency, industrial loads, voltage sag."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/64718"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Conservation voltage reduction (CVR) is an established practice of having the distribution system loads operate at the lower end of the accepted limits based on the standard ANSI C84.1 to provide reduction in power consumption. This standard stipulates optimal voltage levels where the customer equipment is expected to operate with normal performance. CVR has been implemented traditionally by utilities by controlling the voltage on a distribution circuit to the lower end of the tolerance band defined by this standard. The effects of conservation voltage reduction are quantified by a metric called CVR factor (CVR_f). Some references have pointed out that utilities may have a concern about potential reduction in revenue they might incur due to conservation voltage reduction. CVR factor on an average at the distribution feeder level has been discussed to be 0.8. This research investigates the mechanism of saving energy in industrial plants and suggests measures to quantify the CVR factor. The requirements of a device for voltage management are explained. The proposed solution employs coaxial winding transformers whose salient features have been discussed. Existing solutions may have significant issues. Their limited fault handling capability makes them less robust to handle the forces and this may lead to destruction of the equipment or they may experience other issues including sluggish response or low efficiency."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Improving Energy Efficiency and Productivity in Industrial Plants Using Dynamic Voltage Management"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Divan, Deepakraj M."],"dc:contributor.committeemember":["Habetler, Thomas","Saeedifard, Maryam","Brown, Marilyn","Klein, Benjamin"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Jayaraman, Sathish"],"dc:date.accessioned":["2021-06-10T16:52:06Z"],"dc:date.available":["2021-06-10T16:52:06Z"],"dc:date.created":["2021-05"],"dc:date.issued":["2021-03-23"],"dc:date.submitted":["May 2021"],"dc:date.updated":["2021-06-10T16:52:06Z"],"dc:description.abstract":["Conservation voltage reduction (CVR) is an established practice of having the distribution system loads operate at the lower end of the accepted limits based on the standard ANSI C84.1 to provide reduction in power consumption. This standard stipulates optimal voltage levels where the customer equipment is expected to operate with normal performance. CVR has been implemented traditionally by utilities by controlling the voltage on a distribution circuit to the lower end of the tolerance band defined by this standard. The effects of conservation voltage reduction are quantified by a metric called CVR factor (CVR_f). Some references have pointed out that utilities may have a concern about potential reduction in revenue they might incur due to conservation voltage reduction. CVR factor on an average at the distribution feeder level has been discussed to be 0.8. This research investigates the mechanism of saving energy in industrial plants and suggests measures to quantify the CVR factor. The requirements of a device for voltage management are explained. The proposed solution employs coaxial winding transformers whose salient features have been discussed. Existing solutions may have significant issues. Their limited fault handling capability makes them less robust to handle the forces and this may lead to destruction of the equipment or they may experience other issues including sluggish response or low efficiency."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/64718"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["db2b03a1-dd75-4a65-94bb-79e8197e26ea"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Conservation voltage reduction (CVR), fault current and efficiency, industrial loads, voltage sag."],"dc:title":["Improving Energy Efficiency and Productivity in Industrial Plants Using Dynamic Voltage Management"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T04:54:18Z"}