{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/64774"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/64774","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Interfacing systems and synthetic biology for advancements in bacterial biosensor engineering","abstract":"Current detection platforms ranging from clinical diagnostics to environmental pollutant monitoring often require a time-intensive sample analysis process involving expensive equipment and highly-trained staff. This has led to growing demands for faster, less expensive, more user-friendly platforms. Bacteria have the potential to meet these needs, as they can serve as inexpensive, robust biosensors that can be engineered to detect target molecules while providing fast, easily measurable readouts; however, genetic engineering efforts can often incite metabolic changes that limit biosensing performance. Cell-free bacteria-based biosensors, which use a bacterial protein lysate to perform transcription and translation, can avoid many of the challenges of whole-cell biosensor development, but the uncharacterized metabolic activity in cell-free systems creates a new set of obstacles that must be addressed for effective biosensor design. In this work, I use metabolomics (the systems-scale study of small molecule intermediates involved in the chemical reactions within biological systems) to address these key challenges in whole-cell and cell-free systems to improve their development for biosensing applications. For whole-cell systems, I explore the metabolic effects linked to expression and optimization of a well-characterized biosensor reporter system. For cell-free systems, I characterize their endogenous, dynamic metabolic activity and explore the metabolic impacts of various system perturbations. For both platforms, I identify key metabolites that limit the utility of both whole-cell and cell-free systems and present strategies to address some of the limitations in each platform to facilitate improved biosensor engineering and ultimately broaden the reach of whole-cell and cell-free bacteria-based biosensors.","abstract_html":"Current detection platforms ranging from clinical diagnostics to environmental pollutant monitoring often require a time-intensive sample analysis process involving expensive equipment and highly-trained staff. This has led to growing demands for faster, less expensive, more user-friendly platforms. Bacteria have the potential to meet these needs, as they can serve as inexpensive, robust biosensors that can be engineered to detect target molecules while providing fast, easily measurable readouts; however, genetic engineering efforts can often incite metabolic changes that limit biosensing performance. Cell-free bacteria-based biosensors, which use a bacterial protein lysate to perform transcription and translation, can avoid many of the challenges of whole-cell biosensor development, but the uncharacterized metabolic activity in cell-free systems creates a new set of obstacles that must be addressed for effective biosensor design. In this work, I use metabolomics (the systems-scale study of small molecule intermediates involved in the chemical reactions within biological systems) to address these key challenges in whole-cell and cell-free systems to improve their development for biosensing applications. For whole-cell systems, I explore the metabolic effects linked to expression and optimization of a well-characterized biosensor reporter system. For cell-free systems, I characterize their endogenous, dynamic metabolic activity and explore the metabolic impacts of various system perturbations. For both platforms, I identify key metabolites that limit the utility of both whole-cell and cell-free systems and present strategies to address some of the limitations in each platform to facilitate improved biosensor engineering and ultimately broaden the reach of whole-cell and cell-free bacteria-based biosensors.","abstract_has_math":false,"creators":["Miguez, April Marie"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Chemical and Biomolecular Engineering","school":null,"contributors":[],"advisors":["Styczynski, Mark P."],"committee_chairs":[],"committee_members":["Cheung, Lily S","Hickman, Meleah A","Lu, Hang","Wu, Ronghu"],"year":2021,"date_issued":"2021-04-28","date_published":"2021-04-28","updated_at":"2026-11-19T05:50:29Z","subjects":["Metabolomics","Biosensors","Escherichia coli","Cell-free expression systems","Gas-chromatography-mass spectrometry"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/64774","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/64774","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F64774","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Styczynski, Mark P."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Cheung, Lily S","Hickman, Meleah A","Lu, Hang","Wu, Ronghu"]},{"key":"dc:contributor.department","label":"Department","values":["Chemical and Biomolecular Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Chemical and Biomolecular Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Miguez, April Marie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-06-10T16:56:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-06-10T16:56:47Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-05"]},{"key":"dc:date.issued","label":"Date","values":["2021-04-28"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2021"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-06-10T16:56:47Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["932cc32a-66dd-4530-afde-796f557fee0b"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Bioengineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["6cfa2dc6-c5bf-4f6b-99a2-57105d8f7a6f","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["5db25cda-aa52-48d2-8f63-c551ef2c92f4"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Metabolomics","Biosensors","Escherichia coli","Cell-free expression systems","Gas-chromatography-mass spectrometry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/64774"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Current detection platforms ranging from clinical diagnostics to environmental pollutant monitoring often require a time-intensive sample analysis process involving expensive equipment and highly-trained staff. This has led to growing demands for faster, less expensive, more user-friendly platforms. Bacteria have the potential to meet these needs, as they can serve as inexpensive, robust biosensors that can be engineered to detect target molecules while providing fast, easily measurable readouts; however, genetic engineering efforts can often incite metabolic changes that limit biosensing performance. Cell-free bacteria-based biosensors, which use a bacterial protein lysate to perform transcription and translation, can avoid many of the challenges of whole-cell biosensor development, but the uncharacterized metabolic activity in cell-free systems creates a new set of obstacles that must be addressed for effective biosensor design. In this work, I use metabolomics (the systems-scale study of small molecule intermediates involved in the chemical reactions within biological systems) to address these key challenges in whole-cell and cell-free systems to improve their development for biosensing applications. For whole-cell systems, I explore the metabolic effects linked to expression and optimization of a well-characterized biosensor reporter system. For cell-free systems, I characterize their endogenous, dynamic metabolic activity and explore the metabolic impacts of various system perturbations. For both platforms, I identify key metabolites that limit the utility of both whole-cell and cell-free systems and present strategies to address some of the limitations in each platform to facilitate improved biosensor engineering and ultimately broaden the reach of whole-cell and cell-free bacteria-based biosensors."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Interfacing systems and synthetic biology for advancements in bacterial biosensor engineering"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Styczynski, Mark P."],"dc:contributor.committeemember":["Cheung, Lily S","Hickman, Meleah A","Lu, Hang","Wu, Ronghu"],"dc:contributor.department":["Chemical and Biomolecular Engineering"],"dc:contributor.other":["School of Chemical and Biomolecular Engineering","College of Engineering"],"dc:creator":["Miguez, April Marie"],"dc:date.accessioned":["2021-06-10T16:56:47Z"],"dc:date.available":["2021-06-10T16:56:47Z"],"dc:date.created":["2021-05"],"dc:date.issued":["2021-04-28"],"dc:date.submitted":["May 2021"],"dc:date.updated":["2021-06-10T16:56:47Z"],"dc:description.abstract":["Current detection platforms ranging from clinical diagnostics to environmental pollutant monitoring often require a time-intensive sample analysis process involving expensive equipment and highly-trained staff. This has led to growing demands for faster, less expensive, more user-friendly platforms. Bacteria have the potential to meet these needs, as they can serve as inexpensive, robust biosensors that can be engineered to detect target molecules while providing fast, easily measurable readouts; however, genetic engineering efforts can often incite metabolic changes that limit biosensing performance. Cell-free bacteria-based biosensors, which use a bacterial protein lysate to perform transcription and translation, can avoid many of the challenges of whole-cell biosensor development, but the uncharacterized metabolic activity in cell-free systems creates a new set of obstacles that must be addressed for effective biosensor design. In this work, I use metabolomics (the systems-scale study of small molecule intermediates involved in the chemical reactions within biological systems) to address these key challenges in whole-cell and cell-free systems to improve their development for biosensing applications. For whole-cell systems, I explore the metabolic effects linked to expression and optimization of a well-characterized biosensor reporter system. For cell-free systems, I characterize their endogenous, dynamic metabolic activity and explore the metabolic impacts of various system perturbations. For both platforms, I identify key metabolites that limit the utility of both whole-cell and cell-free systems and present strategies to address some of the limitations in each platform to facilitate improved biosensor engineering and ultimately broaden the reach of whole-cell and cell-free bacteria-based biosensors."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/64774"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["932cc32a-66dd-4530-afde-796f557fee0b"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Bioengineering"],"dc:relation.orgunit":["6cfa2dc6-c5bf-4f6b-99a2-57105d8f7a6f","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["5db25cda-aa52-48d2-8f63-c551ef2c92f4"],"dc:subject":["Metabolomics","Biosensors","Escherichia coli","Cell-free expression systems","Gas-chromatography-mass spectrometry"],"dc:title":["Interfacing systems and synthetic biology for advancements in bacterial biosensor engineering"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:50:29Z"}