{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/64969"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/64969","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"The Dynamic Sampling Platform (DSP) for Real-time Bioreactor Monitoring","abstract":"Biomanufacturing for advanced therapies depends on the reliable and reproducible growth of cells. Cells continuously secrete biomolecules that serve as the critical quality attributes (CQAs) for manufacturing, but current sensor technologies are incapable of characterizing these biomarkers in real-time. The Dynamic Sampling Platform (DSP) is a technology for real-time analysis of the chemical content of bioreactors. It synergistically combines aseptic, spatially resolved, direct-from-reactor sampling with inline sample treatment and rapid electrospray ionization mass spectrometry (ESI-MS) sensing to fill the void of existing process analytical technologies for real-time CQA monitoring in biomanufacturing. DSP samples non-invasively from near where cells are growing to capture the rich microenvironment, with high relative concentrations of biomarkers, and subsequently treats these samples for real-time electrospray ionization mass spectrometry (ESI-MS) analysis. ESI-MS is a powerful analytical technology for the detection of biomolecules, but it is hindered by a need for extensive sample treatment which has made the technique largely an offline approach. The DSP utilizes a novel â€œactive sample treatmentâ€ to prepare complex biochemical samples for ESI-MS by conditioning the sample via selective salt removal, MS enhancing chemical infusion, and biomolecule retention. The DSP is produced by employing advanced microfabrication techniques. The final device utilizes a micro-mass exchanger which replaces time consuming sample preparation steps with a ~1 second flow through reactor. The results of this dissertation demonstrate the DSP's utility to help unlock the potential of advanced therapeutic cell manufacturing by providing detailed biochemical information about the process for closed feedback control of bioreactors, allowing for nascent therapies to reach a broad patient population.","abstract_html":"Biomanufacturing for advanced therapies depends on the reliable and reproducible growth of cells. Cells continuously secrete biomolecules that serve as the critical quality attributes (CQAs) for manufacturing, but current sensor technologies are incapable of characterizing these biomarkers in real-time. The Dynamic Sampling Platform (DSP) is a technology for real-time analysis of the chemical content of bioreactors. It synergistically combines aseptic, spatially resolved, direct-from-reactor sampling with inline sample treatment and rapid electrospray ionization mass spectrometry (ESI-MS) sensing to fill the void of existing process analytical technologies for real-time CQA monitoring in biomanufacturing. DSP samples non-invasively from near where cells are growing to capture the rich microenvironment, with high relative concentrations of biomarkers, and subsequently treats these samples for real-time electrospray ionization mass spectrometry (ESI-MS) analysis. ESI-MS is a powerful analytical technology for the detection of biomolecules, but it is hindered by a need for extensive sample treatment which has made the technique largely an offline approach. The DSP utilizes a novel â€œactive sample treatmentâ€ to prepare complex biochemical samples for ESI-MS by conditioning the sample via selective salt removal, MS enhancing chemical infusion, and biomolecule retention. The DSP is produced by employing advanced microfabrication techniques. The final device utilizes a micro-mass exchanger which replaces time consuming sample preparation steps with a ~1 second flow through reactor. The results of this dissertation demonstrate the DSP&#x27;s utility to help unlock the potential of advanced therapeutic cell manufacturing by providing detailed biochemical information about the process for closed feedback control of bioreactors, allowing for nascent therapies to reach a broad patient population.","abstract_has_math":false,"creators":["Chilmonczyk, Mason A."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Fedorov, Andrei G."],"committee_chairs":[],"committee_members":["Kottke, Peter A.","Ku, David N.","Brand, Oliver","Guldberg, Robert E."],"year":2020,"date_issued":"2020-05-19","date_published":"2020-05-19","updated_at":"2026-11-19T06:01:03Z","subjects":["Real-time bioreactor monitoring","Bioreactor monitoring","Process analytical technology","Esi-ms","Cell-state analytics","Microdialysis","Active sample conditioning","Dynamic sampling platform","Critical quality attribute characterization for biomanufacturing","Direct from culture sampling","Inline mass spectrometry","Real-time electrospray ionization mass spectrometry"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/64969","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/64969","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F64969","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fedorov, Andrei G."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kottke, Peter A.","Ku, David N.","Brand, Oliver","Guldberg, Robert E."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Chilmonczyk, Mason A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-09-15T15:32:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-09-15T15:32:16Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-08"]},{"key":"dc:date.issued","label":"Date","values":["2020-05-19"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2020"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-09-15T15:32:16Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["22ed9217-97e1-449b-a93c-6caf41cd08d7"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Real-time bioreactor monitoring","Bioreactor monitoring","Process analytical technology","Esi-ms","Cell-state analytics","Microdialysis","Active sample conditioning","Dynamic sampling platform","Critical quality attribute characterization for biomanufacturing","Direct from culture sampling","Inline mass spectrometry","Real-time electrospray ionization mass spectrometry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/64969"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Biomanufacturing for advanced therapies depends on the reliable and reproducible growth of cells. Cells continuously secrete biomolecules that serve as the critical quality attributes (CQAs) for manufacturing, but current sensor technologies are incapable of characterizing these biomarkers in real-time. The Dynamic Sampling Platform (DSP) is a technology for real-time analysis of the chemical content of bioreactors. It synergistically combines aseptic, spatially resolved, direct-from-reactor sampling with inline sample treatment and rapid electrospray ionization mass spectrometry (ESI-MS) sensing to fill the void of existing process analytical technologies for real-time CQA monitoring in biomanufacturing. DSP samples non-invasively from near where cells are growing to capture the rich microenvironment, with high relative concentrations of biomarkers, and subsequently treats these samples for real-time electrospray ionization mass spectrometry (ESI-MS) analysis. ESI-MS is a powerful analytical technology for the detection of biomolecules, but it is hindered by a need for extensive sample treatment which has made the technique largely an offline approach. The DSP utilizes a novel â€œactive sample treatmentâ€ to prepare complex biochemical samples for ESI-MS by conditioning the sample via selective salt removal, MS enhancing chemical infusion, and biomolecule retention. The DSP is produced by employing advanced microfabrication techniques. The final device utilizes a micro-mass exchanger which replaces time consuming sample preparation steps with a ~1 second flow through reactor. The results of this dissertation demonstrate the DSP's utility to help unlock the potential of advanced therapeutic cell manufacturing by providing detailed biochemical information about the process for closed feedback control of bioreactors, allowing for nascent therapies to reach a broad patient population."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The Dynamic Sampling Platform (DSP) for Real-time Bioreactor Monitoring"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fedorov, Andrei G."],"dc:contributor.committeemember":["Kottke, Peter A.","Ku, David N.","Brand, Oliver","Guldberg, Robert E."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Chilmonczyk, Mason A."],"dc:date.accessioned":["2021-09-15T15:32:16Z"],"dc:date.available":["2021-09-15T15:32:16Z"],"dc:date.created":["2020-08"],"dc:date.issued":["2020-05-19"],"dc:date.submitted":["August 2020"],"dc:date.updated":["2021-09-15T15:32:16Z"],"dc:description.abstract":["Biomanufacturing for advanced therapies depends on the reliable and reproducible growth of cells. Cells continuously secrete biomolecules that serve as the critical quality attributes (CQAs) for manufacturing, but current sensor technologies are incapable of characterizing these biomarkers in real-time. The Dynamic Sampling Platform (DSP) is a technology for real-time analysis of the chemical content of bioreactors. It synergistically combines aseptic, spatially resolved, direct-from-reactor sampling with inline sample treatment and rapid electrospray ionization mass spectrometry (ESI-MS) sensing to fill the void of existing process analytical technologies for real-time CQA monitoring in biomanufacturing. DSP samples non-invasively from near where cells are growing to capture the rich microenvironment, with high relative concentrations of biomarkers, and subsequently treats these samples for real-time electrospray ionization mass spectrometry (ESI-MS) analysis. ESI-MS is a powerful analytical technology for the detection of biomolecules, but it is hindered by a need for extensive sample treatment which has made the technique largely an offline approach. The DSP utilizes a novel â€œactive sample treatmentâ€ to prepare complex biochemical samples for ESI-MS by conditioning the sample via selective salt removal, MS enhancing chemical infusion, and biomolecule retention. The DSP is produced by employing advanced microfabrication techniques. The final device utilizes a micro-mass exchanger which replaces time consuming sample preparation steps with a ~1 second flow through reactor. The results of this dissertation demonstrate the DSP's utility to help unlock the potential of advanced therapeutic cell manufacturing by providing detailed biochemical information about the process for closed feedback control of bioreactors, allowing for nascent therapies to reach a broad patient population."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/64969"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["22ed9217-97e1-449b-a93c-6caf41cd08d7"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Real-time bioreactor monitoring","Bioreactor monitoring","Process analytical technology","Esi-ms","Cell-state analytics","Microdialysis","Active sample conditioning","Dynamic sampling platform","Critical quality attribute characterization for biomanufacturing","Direct from culture sampling","Inline mass spectrometry","Real-time electrospray ionization mass spectrometry"],"dc:title":["The Dynamic Sampling Platform (DSP) for Real-time Bioreactor Monitoring"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T06:01:03Z"}