{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/65024"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/65024","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Neurological Disease Diagnosis and Treatment via Precise Robotic Intervention","abstract":"This work focuses on the development and application of mechatronic systems for measurement, diagnosis and treatment of acute and chronic neurological conditions. The development of an automated tendon reflex stimulation device, as well as analysis and classification methods for both automated and manual stimulus delivery will provide the groundwork for improvements to both diagnosis and treatment of neurological injuries. In a similar vein, development of a variable resonance actuator for Magnetic Resonance Elastography imaging enables tissue property measurement of the intervertebral discs, hopefully providing an early marker and better understanding of degeneration. In addition to MRI based spinal tissue property measurements, an MRI guided high precision robot is developed for direct injection into the spinal cord, along with an accompanying image guided control scheme. The novel parallel plane mechanism enables control of 4 degrees of freedom, while the linear piezoelectric actuators in a direct drive configuration enables superior accuracy. Taken together, these robotic device developments constitute contributions to the field of precision medical robotics with applications to physiological understanding of the human body.","abstract_html":"This work focuses on the development and application of mechatronic systems for measurement, diagnosis and treatment of acute and chronic neurological conditions. The development of an automated tendon reflex stimulation device, as well as analysis and classification methods for both automated and manual stimulus delivery will provide the groundwork for improvements to both diagnosis and treatment of neurological injuries. In a similar vein, development of a variable resonance actuator for Magnetic Resonance Elastography imaging enables tissue property measurement of the intervertebral discs, hopefully providing an early marker and better understanding of degeneration. In addition to MRI based spinal tissue property measurements, an MRI guided high precision robot is developed for direct injection into the spinal cord, along with an accompanying image guided control scheme. The novel parallel plane mechanism enables control of 4 degrees of freedom, while the linear piezoelectric actuators in a direct drive configuration enables superior accuracy. Taken together, these robotic device developments constitute contributions to the field of precision medical robotics with applications to physiological understanding of the human body.","abstract_has_math":false,"creators":["Meinhold, Waiman Modeling"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Ueda, Jun"],"committee_chairs":[],"committee_members":["Hammond, Frank","Desai, Jaydev","Oshinski, John","Hu, Ai-Ping","Kurt, Mehmet"],"year":2021,"date_issued":"2021-05-18","date_published":"2021-05-18","updated_at":"2026-11-19T03:53:50Z","subjects":["Robotics","Rehabilitation","MRI"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/65024","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/65024","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F65024","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ueda, Jun"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hammond, Frank","Desai, Jaydev","Oshinski, John","Hu, Ai-Ping","Kurt, Mehmet"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Meinhold, Waiman Modeling"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-09-15T15:40:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-09-15T15:40:58Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-08"]},{"key":"dc:date.issued","label":"Date","values":["2021-05-18"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2021"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-09-15T15:40:58Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["7ff601c5-b262-4830-8a06-b75c55f5f1c8"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Robotics"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["e03131c9-caaa-4d59-9fc0-b3340280ce5e"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Robotics","Rehabilitation","MRI"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/65024"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work focuses on the development and application of mechatronic systems for measurement, diagnosis and treatment of acute and chronic neurological conditions. The development of an automated tendon reflex stimulation device, as well as analysis and classification methods for both automated and manual stimulus delivery will provide the groundwork for improvements to both diagnosis and treatment of neurological injuries. In a similar vein, development of a variable resonance actuator for Magnetic Resonance Elastography imaging enables tissue property measurement of the intervertebral discs, hopefully providing an early marker and better understanding of degeneration. In addition to MRI based spinal tissue property measurements, an MRI guided high precision robot is developed for direct injection into the spinal cord, along with an accompanying image guided control scheme. The novel parallel plane mechanism enables control of 4 degrees of freedom, while the linear piezoelectric actuators in a direct drive configuration enables superior accuracy. Taken together, these robotic device developments constitute contributions to the field of precision medical robotics with applications to physiological understanding of the human body."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Neurological Disease Diagnosis and Treatment via Precise Robotic Intervention"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ueda, Jun"],"dc:contributor.committeemember":["Hammond, Frank","Desai, Jaydev","Oshinski, John","Hu, Ai-Ping","Kurt, Mehmet"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Meinhold, Waiman Modeling"],"dc:date.accessioned":["2021-09-15T15:40:58Z"],"dc:date.available":["2021-09-15T15:40:58Z"],"dc:date.created":["2021-08"],"dc:date.issued":["2021-05-18"],"dc:date.submitted":["August 2021"],"dc:date.updated":["2021-09-15T15:40:58Z"],"dc:description.abstract":["This work focuses on the development and application of mechatronic systems for measurement, diagnosis and treatment of acute and chronic neurological conditions. The development of an automated tendon reflex stimulation device, as well as analysis and classification methods for both automated and manual stimulus delivery will provide the groundwork for improvements to both diagnosis and treatment of neurological injuries. In a similar vein, development of a variable resonance actuator for Magnetic Resonance Elastography imaging enables tissue property measurement of the intervertebral discs, hopefully providing an early marker and better understanding of degeneration. In addition to MRI based spinal tissue property measurements, an MRI guided high precision robot is developed for direct injection into the spinal cord, along with an accompanying image guided control scheme. The novel parallel plane mechanism enables control of 4 degrees of freedom, while the linear piezoelectric actuators in a direct drive configuration enables superior accuracy. Taken together, these robotic device developments constitute contributions to the field of precision medical robotics with applications to physiological understanding of the human body."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/65024"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["7ff601c5-b262-4830-8a06-b75c55f5f1c8"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Robotics"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["e03131c9-caaa-4d59-9fc0-b3340280ce5e"],"dc:subject":["Robotics","Rehabilitation","MRI"],"dc:title":["Neurological Disease Diagnosis and Treatment via Precise Robotic Intervention"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T03:53:50Z"}