{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/65138"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/65138","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Temperature Prediction in Data Center using Data Driven Modeling","abstract":"Prior research has utilized data driven models to predict temperatures in data centers. This thesis considers and compares several data driven models for thermal predictions in data centers under steady state and transient scenarios. The steady state study compares six different data driven modeling techniques â€“ linear regression, decision trees, artificial neural network (ANN), gaussian process regression (GPR), support vector regression (SVR), and relevance vector regression (RVR). While previous studies have looked at the application of some of these techniques to data center thermal predictions, this thesis compares several additional models. The effect of kernels on SVR and GPR models, and elastic net regularization â€“ a methodology to select more important variables in given dataset, are also explored. It was found that GPR and ANN performed the best among the six data driven models studied. Furthermore, kernels were found to have a significant effect on the error for SVR, while kernels did not have a significant effect on error for GPR. The transient study compares long-short term memory (LSTM), and nonlinear autoregressive network with exogeneous inputs (NARX) in different scenarios. An ensemble was created to reduce the variance in LSTM and NARX predictions. This thesis also explores the possibility of utilizing relatively small datasets for transient temperature predictions in data centers, and how extrapolative input variables affect the prediction. Thermal prediction following computer room air conditioning unit (CRAH) failure and chiller failure scenarios are examined.","abstract_html":"Prior research has utilized data driven models to predict temperatures in data centers. This thesis considers and compares several data driven models for thermal predictions in data centers under steady state and transient scenarios. The steady state study compares six different data driven modeling techniques â€“ linear regression, decision trees, artificial neural network (ANN), gaussian process regression (GPR), support vector regression (SVR), and relevance vector regression (RVR). While previous studies have looked at the application of some of these techniques to data center thermal predictions, this thesis compares several additional models. The effect of kernels on SVR and GPR models, and elastic net regularization â€“ a methodology to select more important variables in given dataset, are also explored. It was found that GPR and ANN performed the best among the six data driven models studied. Furthermore, kernels were found to have a significant effect on the error for SVR, while kernels did not have a significant effect on error for GPR. The transient study compares long-short term memory (LSTM), and nonlinear autoregressive network with exogeneous inputs (NARX) in different scenarios. An ensemble was created to reduce the variance in LSTM and NARX predictions. This thesis also explores the possibility of utilizing relatively small datasets for transient temperature predictions in data centers, and how extrapolative input variables affect the prediction. Thermal prediction following computer room air conditioning unit (CRAH) failure and chiller failure scenarios are examined.","abstract_has_math":false,"creators":["Patel, Dhaval"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Joshi, Yogendra"],"committee_chairs":[],"committee_members":["Yoda, Minami","Kumar, Satish"],"year":2021,"date_issued":"2021-07-27","date_published":"2021-07-27","updated_at":"2026-11-19T05:52:32Z","subjects":["Data center","Temperature Prediction","Data Driven Models","Experimental Measurements","Steady State Predictions","Transient Predictions"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/65138","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/65138","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F65138","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Joshi, Yogendra"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Yoda, Minami","Kumar, Satish"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Patel, Dhaval"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-09-15T15:51:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-09-15T15:51:17Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-08"]},{"key":"dc:date.issued","label":"Date","values":["2021-07-27"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2021"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-09-15T15:51:17Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["63ef328b-076b-44b7-92a9-0f7dd03fa1fa"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Data center","Temperature Prediction","Data Driven Models","Experimental Measurements","Steady State Predictions","Transient Predictions"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/65138"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Prior research has utilized data driven models to predict temperatures in data centers. This thesis considers and compares several data driven models for thermal predictions in data centers under steady state and transient scenarios. The steady state study compares six different data driven modeling techniques â€“ linear regression, decision trees, artificial neural network (ANN), gaussian process regression (GPR), support vector regression (SVR), and relevance vector regression (RVR). While previous studies have looked at the application of some of these techniques to data center thermal predictions, this thesis compares several additional models. The effect of kernels on SVR and GPR models, and elastic net regularization â€“ a methodology to select more important variables in given dataset, are also explored. It was found that GPR and ANN performed the best among the six data driven models studied. Furthermore, kernels were found to have a significant effect on the error for SVR, while kernels did not have a significant effect on error for GPR. The transient study compares long-short term memory (LSTM), and nonlinear autoregressive network with exogeneous inputs (NARX) in different scenarios. An ensemble was created to reduce the variance in LSTM and NARX predictions. This thesis also explores the possibility of utilizing relatively small datasets for transient temperature predictions in data centers, and how extrapolative input variables affect the prediction. Thermal prediction following computer room air conditioning unit (CRAH) failure and chiller failure scenarios are examined."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Temperature Prediction in Data Center using Data Driven Modeling"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Joshi, Yogendra"],"dc:contributor.committeemember":["Yoda, Minami","Kumar, Satish"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Patel, Dhaval"],"dc:date.accessioned":["2021-09-15T15:51:17Z"],"dc:date.available":["2021-09-15T15:51:17Z"],"dc:date.created":["2021-08"],"dc:date.issued":["2021-07-27"],"dc:date.submitted":["August 2021"],"dc:date.updated":["2021-09-15T15:51:17Z"],"dc:description.abstract":["Prior research has utilized data driven models to predict temperatures in data centers. This thesis considers and compares several data driven models for thermal predictions in data centers under steady state and transient scenarios. The steady state study compares six different data driven modeling techniques â€“ linear regression, decision trees, artificial neural network (ANN), gaussian process regression (GPR), support vector regression (SVR), and relevance vector regression (RVR). While previous studies have looked at the application of some of these techniques to data center thermal predictions, this thesis compares several additional models. The effect of kernels on SVR and GPR models, and elastic net regularization â€“ a methodology to select more important variables in given dataset, are also explored. It was found that GPR and ANN performed the best among the six data driven models studied. Furthermore, kernels were found to have a significant effect on the error for SVR, while kernels did not have a significant effect on error for GPR. The transient study compares long-short term memory (LSTM), and nonlinear autoregressive network with exogeneous inputs (NARX) in different scenarios. An ensemble was created to reduce the variance in LSTM and NARX predictions. This thesis also explores the possibility of utilizing relatively small datasets for transient temperature predictions in data centers, and how extrapolative input variables affect the prediction. Thermal prediction following computer room air conditioning unit (CRAH) failure and chiller failure scenarios are examined."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/65138"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["63ef328b-076b-44b7-92a9-0f7dd03fa1fa"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Data center","Temperature Prediction","Data Driven Models","Experimental Measurements","Steady State Predictions","Transient Predictions"],"dc:title":["Temperature Prediction in Data Center using Data Driven Modeling"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:52:32Z"}