{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/65139"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/65139","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Design and Analysis of Capacitive Parametric Ultrasound Transducers for Wireless Power Transfer","abstract":"For wireless ultrasonic power delivery to implantable medical devices, a capacitive parametric ultrasound transducer system is analyzed and improved upon. While 1D modeling had sufficed for proof of concept and power transfer with low efficiency has been demonstrated, a more detailed model gives insight to behavior that were previously overlooked. Simulations of large capacitive membrane arrays show higher power transfer efficiencies in some cases when the array is operating at a higher order mode. Analysis also shows that in tissue, fluid damping dominates the mechanics of the membrane array, allowing the array frequency to be tuned by adjusting the membrane thickness through analytical or finite element methods. To complete the power delivery chain, a modified power rectification circuit is simulated, demonstrated experimentally, and compared to a traditional rectification circuit highlighting improvements in power transfer efficiency. Finally, a capacitive membrane design optimized for 1MHz operation in fluid is fabricated in a cleanroom environment and used to demonstrate viable passive ultrasonic wireless power transfer, from hydrophone to load application.","abstract_html":"For wireless ultrasonic power delivery to implantable medical devices, a capacitive parametric ultrasound transducer system is analyzed and improved upon. While 1D modeling had sufficed for proof of concept and power transfer with low efficiency has been demonstrated, a more detailed model gives insight to behavior that were previously overlooked. Simulations of large capacitive membrane arrays show higher power transfer efficiencies in some cases when the array is operating at a higher order mode. Analysis also shows that in tissue, fluid damping dominates the mechanics of the membrane array, allowing the array frequency to be tuned by adjusting the membrane thickness through analytical or finite element methods. To complete the power delivery chain, a modified power rectification circuit is simulated, demonstrated experimentally, and compared to a traditional rectification circuit highlighting improvements in power transfer efficiency. Finally, a capacitive membrane design optimized for 1MHz operation in fluid is fabricated in a cleanroom environment and used to demonstrate viable passive ultrasonic wireless power transfer, from hydrophone to load application.","abstract_has_math":false,"creators":["Wei, Charles Guo"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Degertekin, F. Levent"],"committee_chairs":[],"committee_members":["Hesketh, Peter","Sabra, Karim"],"year":2021,"date_issued":"2021-07-28","date_published":"2021-07-28","updated_at":"2026-11-19T04:51:09Z","subjects":["Wireless power transfer","Ultrasound transducer","Parametric circuit"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/65139","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/65139","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F65139","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Degertekin, F. Levent"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hesketh, Peter","Sabra, Karim"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Wei, Charles Guo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-09-15T15:51:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-09-15T15:51:19Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-08"]},{"key":"dc:date.issued","label":"Date","values":["2021-07-28"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2021"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-09-15T15:51:19Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["9afd92fe-bb98-4c83-b8ac-fc596320991a"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wireless power transfer","Ultrasound transducer","Parametric circuit"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/65139"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["For wireless ultrasonic power delivery to implantable medical devices, a capacitive parametric ultrasound transducer system is analyzed and improved upon. While 1D modeling had sufficed for proof of concept and power transfer with low efficiency has been demonstrated, a more detailed model gives insight to behavior that were previously overlooked. Simulations of large capacitive membrane arrays show higher power transfer efficiencies in some cases when the array is operating at a higher order mode. Analysis also shows that in tissue, fluid damping dominates the mechanics of the membrane array, allowing the array frequency to be tuned by adjusting the membrane thickness through analytical or finite element methods. To complete the power delivery chain, a modified power rectification circuit is simulated, demonstrated experimentally, and compared to a traditional rectification circuit highlighting improvements in power transfer efficiency. Finally, a capacitive membrane design optimized for 1MHz operation in fluid is fabricated in a cleanroom environment and used to demonstrate viable passive ultrasonic wireless power transfer, from hydrophone to load application."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design and Analysis of Capacitive Parametric Ultrasound Transducers for Wireless Power Transfer"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Degertekin, F. Levent"],"dc:contributor.committeemember":["Hesketh, Peter","Sabra, Karim"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Wei, Charles Guo"],"dc:date.accessioned":["2021-09-15T15:51:19Z"],"dc:date.available":["2021-09-15T15:51:19Z"],"dc:date.created":["2021-08"],"dc:date.issued":["2021-07-28"],"dc:date.submitted":["August 2021"],"dc:date.updated":["2021-09-15T15:51:19Z"],"dc:description.abstract":["For wireless ultrasonic power delivery to implantable medical devices, a capacitive parametric ultrasound transducer system is analyzed and improved upon. While 1D modeling had sufficed for proof of concept and power transfer with low efficiency has been demonstrated, a more detailed model gives insight to behavior that were previously overlooked. Simulations of large capacitive membrane arrays show higher power transfer efficiencies in some cases when the array is operating at a higher order mode. Analysis also shows that in tissue, fluid damping dominates the mechanics of the membrane array, allowing the array frequency to be tuned by adjusting the membrane thickness through analytical or finite element methods. To complete the power delivery chain, a modified power rectification circuit is simulated, demonstrated experimentally, and compared to a traditional rectification circuit highlighting improvements in power transfer efficiency. Finally, a capacitive membrane design optimized for 1MHz operation in fluid is fabricated in a cleanroom environment and used to demonstrate viable passive ultrasonic wireless power transfer, from hydrophone to load application."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/65139"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["9afd92fe-bb98-4c83-b8ac-fc596320991a"],"dc:relation.ispartofseries":["Master of Science in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"],"dc:subject":["Wireless power transfer","Ultrasound transducer","Parametric circuit"],"dc:title":["Design and Analysis of Capacitive Parametric Ultrasound Transducers for Wireless Power Transfer"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T04:51:09Z"}