{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/66108"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/66108","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Quantitative Phase Imaging: Instrumentation, Validation, and Annular Illumination","abstract":"The imaging of transparent objects like biological cells and optical fibers is difficult using conventional optical microscopy. Quantitative Phase Imaging (QPI) provides a label-free, quantitative, and reliable way of imaging transparent objects. Conventionally, disk illumination has been widely used as a standard illumination type in microscopy. However, annular illumination provides a way to enhance contrast and improve resolution. In this work, the phase recovery performance of the two illumination types was compared using 2D QPI experiments performed on a standard-type phase test chart using weighted-least squares multifilter phase imaging with partially coherent light (WLS-MFPI-PC). A state-of-the-art QPI system with 2D QPI and 3D QPI capabilities was developed for performing the experiments and is described in detail. The reconstructed phase images were compared to an ideal image using spatial frequency response. Furthermore, the comparison results were found to match the theoretical predictions from MFPI-PC showing the significant advantage of annular illumination in higher spatial frequencies. Thus, the model used to describe the optics of QPI for the two illumination types was validated. A summary of the paraxial, non-paraxial, and WLS-MFPI-PC theories is also provided for the readers.","abstract_html":"The imaging of transparent objects like biological cells and optical fibers is difficult using conventional optical microscopy. Quantitative Phase Imaging (QPI) provides a label-free, quantitative, and reliable way of imaging transparent objects. Conventionally, disk illumination has been widely used as a standard illumination type in microscopy. However, annular illumination provides a way to enhance contrast and improve resolution. In this work, the phase recovery performance of the two illumination types was compared using 2D QPI experiments performed on a standard-type phase test chart using weighted-least squares multifilter phase imaging with partially coherent light (WLS-MFPI-PC). A state-of-the-art QPI system with 2D QPI and 3D QPI capabilities was developed for performing the experiments and is described in detail. The reconstructed phase images were compared to an ideal image using spatial frequency response. Furthermore, the comparison results were found to match the theoretical predictions from MFPI-PC showing the significant advantage of annular illumination in higher spatial frequencies. Thus, the model used to describe the optics of QPI for the two illumination types was validated. A summary of the paraxial, non-paraxial, and WLS-MFPI-PC theories is also provided for the readers.","abstract_has_math":false,"creators":["Kulkarni, Pranav Prasad"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Gaylord, Thomas K."],"committee_chairs":[],"committee_members":["Ralph, Stephen E","Cai, Wenshan","Tibuleac, Sorin","Bao, Yijun"],"year":2021,"date_issued":"2021-12-03","date_published":"2021-12-03","updated_at":"2026-11-19T05:01:40Z","subjects":["Quantitative Phase Imaging, annular illumination, QPI, MFPI-PC, phase imaging"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/66108","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/66108","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F66108","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gaylord, Thomas K."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ralph, Stephen E","Cai, Wenshan","Tibuleac, Sorin","Bao, Yijun"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Kulkarni, Pranav Prasad"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-01-14T16:09:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-01-14T16:09:41Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-12"]},{"key":"dc:date.issued","label":"Date","values":["2021-12-03"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2021"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2022-01-14T16:09:42Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["517427a4-7861-4be9-93e0-6f49e3fa31ea"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f8b6e739-0ecd-4831-80cd-4ef4edf0a817"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Quantitative Phase Imaging, annular illumination, QPI, MFPI-PC, phase imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/66108"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The imaging of transparent objects like biological cells and optical fibers is difficult using conventional optical microscopy. Quantitative Phase Imaging (QPI) provides a label-free, quantitative, and reliable way of imaging transparent objects. Conventionally, disk illumination has been widely used as a standard illumination type in microscopy. However, annular illumination provides a way to enhance contrast and improve resolution. In this work, the phase recovery performance of the two illumination types was compared using 2D QPI experiments performed on a standard-type phase test chart using weighted-least squares multifilter phase imaging with partially coherent light (WLS-MFPI-PC). A state-of-the-art QPI system with 2D QPI and 3D QPI capabilities was developed for performing the experiments and is described in detail. The reconstructed phase images were compared to an ideal image using spatial frequency response. Furthermore, the comparison results were found to match the theoretical predictions from MFPI-PC showing the significant advantage of annular illumination in higher spatial frequencies. Thus, the model used to describe the optics of QPI for the two illumination types was validated. A summary of the paraxial, non-paraxial, and WLS-MFPI-PC theories is also provided for the readers."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Quantitative Phase Imaging: Instrumentation, Validation, and Annular Illumination"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gaylord, Thomas K."],"dc:contributor.committeemember":["Ralph, Stephen E","Cai, Wenshan","Tibuleac, Sorin","Bao, Yijun"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Kulkarni, Pranav Prasad"],"dc:date.accessioned":["2022-01-14T16:09:41Z"],"dc:date.available":["2022-01-14T16:09:41Z"],"dc:date.created":["2021-12"],"dc:date.issued":["2021-12-03"],"dc:date.submitted":["December 2021"],"dc:date.updated":["2022-01-14T16:09:42Z"],"dc:description.abstract":["The imaging of transparent objects like biological cells and optical fibers is difficult using conventional optical microscopy. Quantitative Phase Imaging (QPI) provides a label-free, quantitative, and reliable way of imaging transparent objects. Conventionally, disk illumination has been widely used as a standard illumination type in microscopy. However, annular illumination provides a way to enhance contrast and improve resolution. In this work, the phase recovery performance of the two illumination types was compared using 2D QPI experiments performed on a standard-type phase test chart using weighted-least squares multifilter phase imaging with partially coherent light (WLS-MFPI-PC). A state-of-the-art QPI system with 2D QPI and 3D QPI capabilities was developed for performing the experiments and is described in detail. The reconstructed phase images were compared to an ideal image using spatial frequency response. Furthermore, the comparison results were found to match the theoretical predictions from MFPI-PC showing the significant advantage of annular illumination in higher spatial frequencies. Thus, the model used to describe the optics of QPI for the two illumination types was validated. A summary of the paraxial, non-paraxial, and WLS-MFPI-PC theories is also provided for the readers."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/66108"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["517427a4-7861-4be9-93e0-6f49e3fa31ea"],"dc:relation.ispartofseries":["Master of Science in Electrical and Computer Engineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["f8b6e739-0ecd-4831-80cd-4ef4edf0a817"],"dc:subject":["Quantitative Phase Imaging, annular illumination, QPI, MFPI-PC, phase imaging"],"dc:title":["Quantitative Phase Imaging: Instrumentation, Validation, and Annular Illumination"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:01:40Z"}