{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/66632"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/66632","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"STRUCTURAL TESTING OF NON-PROPRIETARY UHPC FOR CLOSURE POURS BETWEEN PRECAST BRDIGE DECK PANELS","abstract":"Many bridges in the United States are in need of some sort of rehabilitation, repair, or replacement. However, the three broad solutions mentioned are expensive both in their direct and indirect costs. In order to help reduce these costs, accelerated bridge construction makes use of precast concrete elements which need to be connected on-site. Ultra-high performance concrete (UHPC) has proven to be useful for this application, but it is an expensive material. This research covers investigations into the development of a non-proprietary UHPC intended to be more cost- effective solution for connecting precast deck panels in the state of Georgia. The research reported is an extension of the work from previous researchers, who developed a cost-effective mix of non-proprietary UHPC. However, further investigations were necessary. Successfully mixing a batch of the UHPC based on procedures outline by previous researchers proved the ability of the mix to be readily recreated. Insight is also provided into the consequences of using improper mixing equipment. Mechanical testing further verified the high compressive strengths of the UHPC, while a brief investigation into the shape effects of compression and flexural specimens was also launched. The primary goal of this research was to perform large-scale structural tests. Four of these tests were performed successfully and detailed reports from observing these tests followed. Insights were gained from these tests as to the viability of the non-proprietary mix for closure pour applications. The mix proved successful in this regard, indicated by all four-large scale structural test specimens failing via crushing of the precast concrete panels rather than failure being governed by the UHPC joint. The UHPC joint allowed most specimens to achieve their nominal capacity, with few exceptions caused by improper curing conditions.","abstract_html":"Many bridges in the United States are in need of some sort of rehabilitation, repair, or replacement. However, the three broad solutions mentioned are expensive both in their direct and indirect costs. In order to help reduce these costs, accelerated bridge construction makes use of precast concrete elements which need to be connected on-site. Ultra-high performance concrete (UHPC) has proven to be useful for this application, but it is an expensive material. This research covers investigations into the development of a non-proprietary UHPC intended to be more cost- effective solution for connecting precast deck panels in the state of Georgia. The research reported is an extension of the work from previous researchers, who developed a cost-effective mix of non-proprietary UHPC. However, further investigations were necessary. Successfully mixing a batch of the UHPC based on procedures outline by previous researchers proved the ability of the mix to be readily recreated. Insight is also provided into the consequences of using improper mixing equipment. Mechanical testing further verified the high compressive strengths of the UHPC, while a brief investigation into the shape effects of compression and flexural specimens was also launched. The primary goal of this research was to perform large-scale structural tests. Four of these tests were performed successfully and detailed reports from observing these tests followed. Insights were gained from these tests as to the viability of the non-proprietary mix for closure pour applications. The mix proved successful in this regard, indicated by all four-large scale structural test specimens failing via crushing of the precast concrete panels rather than failure being governed by the UHPC joint. The UHPC joint allowed most specimens to achieve their nominal capacity, with few exceptions caused by improper curing conditions.","abstract_has_math":false,"creators":["Fish, Griffin Kylan"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Stewart, Lauren K."],"committee_chairs":[],"committee_members":["Kahn, Lawrence F.","Loreto, Giovanni"],"year":2022,"date_issued":"2022-05-03","date_published":"2022-05-03","updated_at":"2026-11-19T05:11:28Z","subjects":["UHPC","closure pour","precast","structural testing","non-proprietary","compression testing","flexural testing","accelerated bridge construction","mixing","force-displacement"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/66632","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/66632","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F66632","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Stewart, Lauren K."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kahn, Lawrence F.","Loreto, Giovanni"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Fish, Griffin Kylan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-05-18T19:37:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-05-18T19:37:36Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-05"]},{"key":"dc:date.issued","label":"Date","values":["2022-05-03"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2022"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2022-05-18T19:37:37Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["60b8f550-7e84-4d16-9a91-c65a26bac475"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Civil Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["451ac1ce-0dd6-43a5-8843-bae81fd68e33"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["UHPC","closure pour","precast","structural testing","non-proprietary","compression testing","flexural testing","accelerated bridge construction","mixing","force-displacement"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/66632"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Many bridges in the United States are in need of some sort of rehabilitation, repair, or replacement. However, the three broad solutions mentioned are expensive both in their direct and indirect costs. In order to help reduce these costs, accelerated bridge construction makes use of precast concrete elements which need to be connected on-site. Ultra-high performance concrete (UHPC) has proven to be useful for this application, but it is an expensive material. This research covers investigations into the development of a non-proprietary UHPC intended to be more cost- effective solution for connecting precast deck panels in the state of Georgia. The research reported is an extension of the work from previous researchers, who developed a cost-effective mix of non-proprietary UHPC. However, further investigations were necessary. Successfully mixing a batch of the UHPC based on procedures outline by previous researchers proved the ability of the mix to be readily recreated. Insight is also provided into the consequences of using improper mixing equipment. Mechanical testing further verified the high compressive strengths of the UHPC, while a brief investigation into the shape effects of compression and flexural specimens was also launched. The primary goal of this research was to perform large-scale structural tests. Four of these tests were performed successfully and detailed reports from observing these tests followed. Insights were gained from these tests as to the viability of the non-proprietary mix for closure pour applications. The mix proved successful in this regard, indicated by all four-large scale structural test specimens failing via crushing of the precast concrete panels rather than failure being governed by the UHPC joint. The UHPC joint allowed most specimens to achieve their nominal capacity, with few exceptions caused by improper curing conditions."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["STRUCTURAL TESTING OF NON-PROPRIETARY UHPC FOR CLOSURE POURS BETWEEN PRECAST BRDIGE DECK PANELS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Stewart, Lauren K."],"dc:contributor.committeemember":["Kahn, Lawrence F.","Loreto, Giovanni"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Fish, Griffin Kylan"],"dc:date.accessioned":["2022-05-18T19:37:36Z"],"dc:date.available":["2022-05-18T19:37:36Z"],"dc:date.created":["2022-05"],"dc:date.issued":["2022-05-03"],"dc:date.submitted":["May 2022"],"dc:date.updated":["2022-05-18T19:37:37Z"],"dc:description.abstract":["Many bridges in the United States are in need of some sort of rehabilitation, repair, or replacement. However, the three broad solutions mentioned are expensive both in their direct and indirect costs. In order to help reduce these costs, accelerated bridge construction makes use of precast concrete elements which need to be connected on-site. Ultra-high performance concrete (UHPC) has proven to be useful for this application, but it is an expensive material. This research covers investigations into the development of a non-proprietary UHPC intended to be more cost- effective solution for connecting precast deck panels in the state of Georgia. The research reported is an extension of the work from previous researchers, who developed a cost-effective mix of non-proprietary UHPC. However, further investigations were necessary. Successfully mixing a batch of the UHPC based on procedures outline by previous researchers proved the ability of the mix to be readily recreated. Insight is also provided into the consequences of using improper mixing equipment. Mechanical testing further verified the high compressive strengths of the UHPC, while a brief investigation into the shape effects of compression and flexural specimens was also launched. The primary goal of this research was to perform large-scale structural tests. Four of these tests were performed successfully and detailed reports from observing these tests followed. Insights were gained from these tests as to the viability of the non-proprietary mix for closure pour applications. The mix proved successful in this regard, indicated by all four-large scale structural test specimens failing via crushing of the precast concrete panels rather than failure being governed by the UHPC joint. The UHPC joint allowed most specimens to achieve their nominal capacity, with few exceptions caused by improper curing conditions."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/66632"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["60b8f550-7e84-4d16-9a91-c65a26bac475"],"dc:relation.ispartofseries":["Master of Science in Civil Engineering"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["451ac1ce-0dd6-43a5-8843-bae81fd68e33"],"dc:subject":["UHPC","closure pour","precast","structural testing","non-proprietary","compression testing","flexural testing","accelerated bridge construction","mixing","force-displacement"],"dc:title":["STRUCTURAL TESTING OF NON-PROPRIETARY UHPC FOR CLOSURE POURS BETWEEN PRECAST BRDIGE DECK PANELS"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:11:28Z"}