{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/67097"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/67097","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"THE EFFECT OF SAMPLING RATE AND SIGNAL-TO-NOISE RATIO ON METHODS FOR THE AUTOMATED DETERMINATION OF SUSTAINED MAXIMUM AMPLITUDES IN VIBRATION SIGNALS","abstract":"Machine condition monitoring has been proven to reduce machine down time and increase productivity. State of the art research uses vibration monitoring for tasks such as maintenance and tool wear prediction. A less explored aspect is how vibration monitoring might be used to monitor equipment sensitive to vibration. In a manufacturing environment, one example of where this might be needed is in monitoring the vibration of optical linear encoders used in high precision machine tools and coordinate measuring machines. Monitoring the vibration of sensitive equipment presents a unique case for vibration monitoring because an accurate representation of the maximum sustained vibration is needed, as opposed to extracting trends from the data. To do this, techniques for determining sustained peaks in vibration signals are needed. This thesis fills this gap by formalizing and testing methods for determining sustained vibration amplitudes. The methods developed are tested on simulated signals based on experimental data. Results show that processing the signal directly with the novel Expire Timer method produces the smallest amounts of error on average under the various test conditions. Additionally, this method can operate in real-time on streaming vibration data.","abstract_html":"Machine condition monitoring has been proven to reduce machine down time and increase productivity. State of the art research uses vibration monitoring for tasks such as maintenance and tool wear prediction. A less explored aspect is how vibration monitoring might be used to monitor equipment sensitive to vibration. In a manufacturing environment, one example of where this might be needed is in monitoring the vibration of optical linear encoders used in high precision machine tools and coordinate measuring machines. Monitoring the vibration of sensitive equipment presents a unique case for vibration monitoring because an accurate representation of the maximum sustained vibration is needed, as opposed to extracting trends from the data. To do this, techniques for determining sustained peaks in vibration signals are needed. This thesis fills this gap by formalizing and testing methods for determining sustained vibration amplitudes. The methods developed are tested on simulated signals based on experimental data. Results show that processing the signal directly with the novel Expire Timer method produces the smallest amounts of error on average under the various test conditions. Additionally, this method can operate in real-time on streaming vibration data.","abstract_has_math":false,"creators":["DeVol, Nathaniel S."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Saldaña, Christopher J.","Fu, Katherine"],"committee_chairs":[],"committee_members":["Kurfess, Thomas"],"year":2021,"date_issued":"2021-05-25","date_published":"2021-05-25","updated_at":"2026-11-19T05:09:57Z","subjects":["burst detection","sustained amplitudes","vibration analysis","optical encoders"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/67097","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/67097","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F67097","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Saldaña, Christopher J.","Fu, Katherine"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kurfess, Thomas"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["DeVol, Nathaniel S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-08-25T13:25:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-08-25T13:25:20Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-08"]},{"key":"dc:date.issued","label":"Date","values":["2021-05-25"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2021"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2022-08-25T13:25:20Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["6a3b202b-a552-45bf-a034-0b8e33c4a6bb","ebcbc0bb-bdfa-4173-b96f-757ab82cd90c"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["burst detection","sustained amplitudes","vibration analysis","optical encoders"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/67097"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Machine condition monitoring has been proven to reduce machine down time and increase productivity. State of the art research uses vibration monitoring for tasks such as maintenance and tool wear prediction. A less explored aspect is how vibration monitoring might be used to monitor equipment sensitive to vibration. In a manufacturing environment, one example of where this might be needed is in monitoring the vibration of optical linear encoders used in high precision machine tools and coordinate measuring machines. Monitoring the vibration of sensitive equipment presents a unique case for vibration monitoring because an accurate representation of the maximum sustained vibration is needed, as opposed to extracting trends from the data. To do this, techniques for determining sustained peaks in vibration signals are needed. This thesis fills this gap by formalizing and testing methods for determining sustained vibration amplitudes. The methods developed are tested on simulated signals based on experimental data. Results show that processing the signal directly with the novel Expire Timer method produces the smallest amounts of error on average under the various test conditions. Additionally, this method can operate in real-time on streaming vibration data."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["THE EFFECT OF SAMPLING RATE AND SIGNAL-TO-NOISE RATIO ON METHODS FOR THE AUTOMATED DETERMINATION OF SUSTAINED MAXIMUM AMPLITUDES IN VIBRATION SIGNALS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Saldaña, Christopher J.","Fu, Katherine"],"dc:contributor.committeemember":["Kurfess, Thomas"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["DeVol, Nathaniel S."],"dc:date.accessioned":["2022-08-25T13:25:20Z"],"dc:date.available":["2022-08-25T13:25:20Z"],"dc:date.created":["2021-08"],"dc:date.issued":["2021-05-25"],"dc:date.submitted":["August 2021"],"dc:date.updated":["2022-08-25T13:25:20Z"],"dc:description.abstract":["Machine condition monitoring has been proven to reduce machine down time and increase productivity. State of the art research uses vibration monitoring for tasks such as maintenance and tool wear prediction. A less explored aspect is how vibration monitoring might be used to monitor equipment sensitive to vibration. In a manufacturing environment, one example of where this might be needed is in monitoring the vibration of optical linear encoders used in high precision machine tools and coordinate measuring machines. Monitoring the vibration of sensitive equipment presents a unique case for vibration monitoring because an accurate representation of the maximum sustained vibration is needed, as opposed to extracting trends from the data. To do this, techniques for determining sustained peaks in vibration signals are needed. This thesis fills this gap by formalizing and testing methods for determining sustained vibration amplitudes. The methods developed are tested on simulated signals based on experimental data. Results show that processing the signal directly with the novel Expire Timer method produces the smallest amounts of error on average under the various test conditions. Additionally, this method can operate in real-time on streaming vibration data."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/67097"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["6a3b202b-a552-45bf-a034-0b8e33c4a6bb","ebcbc0bb-bdfa-4173-b96f-757ab82cd90c"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["burst detection","sustained amplitudes","vibration analysis","optical encoders"],"dc:title":["THE EFFECT OF SAMPLING RATE AND SIGNAL-TO-NOISE RATIO ON METHODS FOR THE AUTOMATED DETERMINATION OF SUSTAINED MAXIMUM AMPLITUDES IN VIBRATION SIGNALS"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:09:57Z"}