{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/6851"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/6851","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Design, Fabrication and Testing of a Wearable Cooling System","abstract":"A wearable cooling system was developed in this study for use in elevated temperature environments by military, fire-fighting, chemical-response, and other hazardous duty personnel. Such a system is expected to reduce heat-related stresses, increasing productivity and allowable mission duration, reduce fatigue, and lead to a safer working environment. The cooling system consists of an engine-driven vapor-compression system assembled in a backpack configuration, coupled with a cooling garment containing refrigerant lines worn in close proximity to the skin. A 2.0 L fuel tank in the backpack powers a small-scale engine that runs a compressor modified from the original air compression application to the refrigerant compression application here. A centrifugal clutch and reduction gear train system was designed and fabricated to couple the engine output to the refrigerant compressor and heat rejection fan. The overall cooling system, including the wearable evaporator, had a total mass of 5.31 kg (11.7 lb) and measured 0.318 נ0.273 נ0.152 m (12.5 נ10.75 נ6 inches). Testing was conducted in a controlled environment to determine system performance over a wide range of expected ambient temperatures (37.7-47.5㩬 evaporator refrigerant temperatures (22.2-26.1㩬 and engine speeds (10,500-13,300 RPM). Heat removal rates of up to 300 W, which is the cooling rate established in the literature as being required for maintaining comfort at an activity level comparable to calisthenics or moderate exercise, were demonstrated at a nominal ambient temperature of 43.3㠨110橮 Modeling the fuel as 88 percent methanol (LHV ~ 1.992ױ07 J/kg) and 12 percent oil, the system consumed 1750 W at an average fuel mass flow rate of 0.316 kg/hr to provide a nominal cooling rate of 178 W for 5.7 hrs between refueling.","abstract_html":"A wearable cooling system was developed in this study for use in elevated temperature environments by military, fire-fighting, chemical-response, and other hazardous duty personnel. Such a system is expected to reduce heat-related stresses, increasing productivity and allowable mission duration, reduce fatigue, and lead to a safer working environment. The cooling system consists of an engine-driven vapor-compression system assembled in a backpack configuration, coupled with a cooling garment containing refrigerant lines worn in close proximity to the skin. A 2.0 L fuel tank in the backpack powers a small-scale engine that runs a compressor modified from the original air compression application to the refrigerant compression application here. A centrifugal clutch and reduction gear train system was designed and fabricated to couple the engine output to the refrigerant compressor and heat rejection fan. The overall cooling system, including the wearable evaporator, had a total mass of 5.31 kg (11.7 lb) and measured 0.318 נ0.273 נ0.152 m (12.5 נ10.75 נ6 inches). Testing was conducted in a controlled environment to determine system performance over a wide range of expected ambient temperatures (37.7-47.5㩬 evaporator refrigerant temperatures (22.2-26.1㩬 and engine speeds (10,500-13,300 RPM). Heat removal rates of up to 300 W, which is the cooling rate established in the literature as being required for maintaining comfort at an activity level comparable to calisthenics or moderate exercise, were demonstrated at a nominal ambient temperature of 43.3㠨110橮 Modeling the fuel as 88 percent methanol (LHV ~ 1.992ױ07 J/kg) and 12 percent oil, the system consumed 1750 W at an average fuel mass flow rate of 0.316 kg/hr to provide a nominal cooling rate of 178 W for 5.7 hrs between refueling.","abstract_has_math":false,"creators":["Ernst, Timothy Craig"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Garimella, Srinivas"],"committee_chairs":[],"committee_members":["Rosen, David","Shelton, Samuel"],"year":2005,"date_issued":"2005-02-14","date_published":"2005-02-14","updated_at":"2026-11-19T04:52:05Z","subjects":["Personal cooling","Portable cooling device"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/6851","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/6851","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F6851","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Garimella, Srinivas"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Rosen, David","Shelton, Samuel"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Ernst, Timothy Craig"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-07-28T17:52:40Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-07-28T17:52:40Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-02-14"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["7c74399b-6962-4814-9d2a-51f8b9c41e1f"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Personal cooling","Portable cooling device"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/6851"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A wearable cooling system was developed in this study for use in elevated temperature environments by military, fire-fighting, chemical-response, and other hazardous duty personnel. Such a system is expected to reduce heat-related stresses, increasing productivity and allowable mission duration, reduce fatigue, and lead to a safer working environment. The cooling system consists of an engine-driven vapor-compression system assembled in a backpack configuration, coupled with a cooling garment containing refrigerant lines worn in close proximity to the skin. A 2.0 L fuel tank in the backpack powers a small-scale engine that runs a compressor modified from the original air compression application to the refrigerant compression application here. A centrifugal clutch and reduction gear train system was designed and fabricated to couple the engine output to the refrigerant compressor and heat rejection fan. The overall cooling system, including the wearable evaporator, had a total mass of 5.31 kg (11.7 lb) and measured 0.318 נ0.273 נ0.152 m (12.5 נ10.75 נ6 inches). Testing was conducted in a controlled environment to determine system performance over a wide range of expected ambient temperatures (37.7-47.5㩬 evaporator refrigerant temperatures (22.2-26.1㩬 and engine speeds (10,500-13,300 RPM). Heat removal rates of up to 300 W, which is the cooling rate established in the literature as being required for maintaining comfort at an activity level comparable to calisthenics or moderate exercise, were demonstrated at a nominal ambient temperature of 43.3㠨110橮 Modeling the fuel as 88 percent methanol (LHV ~ 1.992ױ07 J/kg) and 12 percent oil, the system consumed 1750 W at an average fuel mass flow rate of 0.316 kg/hr to provide a nominal cooling rate of 178 W for 5.7 hrs between refueling."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["3034656 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design, Fabrication and Testing of a Wearable Cooling System"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Garimella, Srinivas"],"dc:contributor.committeemember":["Rosen, David","Shelton, Samuel"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Ernst, Timothy Craig"],"dc:date.accessioned":["2005-07-28T17:52:40Z"],"dc:date.available":["2005-07-28T17:52:40Z"],"dc:date.issued":["2005-02-14"],"dc:description.abstract":["A wearable cooling system was developed in this study for use in elevated temperature environments by military, fire-fighting, chemical-response, and other hazardous duty personnel. Such a system is expected to reduce heat-related stresses, increasing productivity and allowable mission duration, reduce fatigue, and lead to a safer working environment. The cooling system consists of an engine-driven vapor-compression system assembled in a backpack configuration, coupled with a cooling garment containing refrigerant lines worn in close proximity to the skin. A 2.0 L fuel tank in the backpack powers a small-scale engine that runs a compressor modified from the original air compression application to the refrigerant compression application here. A centrifugal clutch and reduction gear train system was designed and fabricated to couple the engine output to the refrigerant compressor and heat rejection fan. The overall cooling system, including the wearable evaporator, had a total mass of 5.31 kg (11.7 lb) and measured 0.318 נ0.273 נ0.152 m (12.5 נ10.75 נ6 inches). Testing was conducted in a controlled environment to determine system performance over a wide range of expected ambient temperatures (37.7-47.5㩬 evaporator refrigerant temperatures (22.2-26.1㩬 and engine speeds (10,500-13,300 RPM). Heat removal rates of up to 300 W, which is the cooling rate established in the literature as being required for maintaining comfort at an activity level comparable to calisthenics or moderate exercise, were demonstrated at a nominal ambient temperature of 43.3㠨110橮 Modeling the fuel as 88 percent methanol (LHV ~ 1.992ױ07 J/kg) and 12 percent oil, the system consumed 1750 W at an average fuel mass flow rate of 0.316 kg/hr to provide a nominal cooling rate of 178 W for 5.7 hrs between refueling."],"dc:description.degree":["M.S."],"dc:format.extent":["3034656 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/6851"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["7c74399b-6962-4814-9d2a-51f8b9c41e1f"],"dc:relation.ispartofseries":["Master of Science in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"],"dc:subject":["Personal cooling","Portable cooling device"],"dc:title":["Design, Fabrication and Testing of a Wearable Cooling System"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T04:52:05Z"}