{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/70086"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/70086","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Enabling Wearable Hemodynamic Monitoring Using Multimodal Cardiomechanical Sensing Systems","abstract":"Hemodynamic parameters such as blood pressure and stroke volume are instrumental to understanding the pathogenesis of cardiovascular disease. Unfortunately, the monitoring of these hemodynamic parameters is still limited to in-clinic measurements and cumbersome hardware precludes convenient, ubiquitous use. To address this burden, in this work, we explore seismocardiogram-based wearable multimodal sensing techniques to estimate blood pressure and stroke volume. First, the performance of a multimodal, wrist-worn device capable of obtaining noninvasive pulse transit time measurements is used to estimate blood pressure in an unsupervised, at-home setting. Second, the feasibility of this wrist-worn device is comprehensively evaluated in a diverse and medically underserved population over the course of several perturbations used to modulate blood pressure through different pathways. Finally, the ability of wearable signals—acquired from a custom chest-worn biosensor—to noninvasively quantify stroke volume in patients with congenital heart disease is examined in a hospital setting. Collectively, this work demonstrates the advancements necessary towards enabling noninvasive, longitudinal, and accurate measurements of these hemodynamic parameters in remote settings, which offers to improve health equity and disease monitoring in low-resource settings.","abstract_html":"Hemodynamic parameters such as blood pressure and stroke volume are instrumental to understanding the pathogenesis of cardiovascular disease. Unfortunately, the monitoring of these hemodynamic parameters is still limited to in-clinic measurements and cumbersome hardware precludes convenient, ubiquitous use. To address this burden, in this work, we explore seismocardiogram-based wearable multimodal sensing techniques to estimate blood pressure and stroke volume. First, the performance of a multimodal, wrist-worn device capable of obtaining noninvasive pulse transit time measurements is used to estimate blood pressure in an unsupervised, at-home setting. Second, the feasibility of this wrist-worn device is comprehensively evaluated in a diverse and medically underserved population over the course of several perturbations used to modulate blood pressure through different pathways. Finally, the ability of wearable signals—acquired from a custom chest-worn biosensor—to noninvasively quantify stroke volume in patients with congenital heart disease is examined in a hospital setting. Collectively, this work demonstrates the advancements necessary towards enabling noninvasive, longitudinal, and accurate measurements of these hemodynamic parameters in remote settings, which offers to improve health equity and disease monitoring in low-resource settings.","abstract_has_math":false,"creators":["Ganti, Venu G."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Inan, Omer T."],"committee_chairs":[],"committee_members":["Frakes, David H.","Kamaleswaran, Rishikesan","Hahn, Jin-Oh","Tandon, Animesh"],"year":2021,"date_issued":"2021-12-14","date_published":"2021-12-14","updated_at":"2026-11-19T05:14:04Z","subjects":["Wearables","Noninvasive","Cardiovascular, Seismocardiogram","Photoplethysmogram","Biosignals","Machine learning","Multimodal","Stroke volume","Cardiac output","Blood pressure","Congenital heart disease","Hypertension"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/70086","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/70086","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F70086","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Inan, Omer T."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Frakes, David H.","Kamaleswaran, Rishikesan","Hahn, Jin-Oh","Tandon, Animesh"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Electrical and Computer Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Ganti, Venu G."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-01-10T16:20:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-01-10T16:20:57Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-12"]},{"key":"dc:date.issued","label":"Date","values":["2021-12-14"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2021"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2023-01-10T16:20:57Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["fb82ce90-ad3a-45a6-b0e2-f1ee6fe6f744"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Bioengineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["5db25cda-aa52-48d2-8f63-c551ef2c92f4"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wearables","Noninvasive","Cardiovascular, Seismocardiogram","Photoplethysmogram","Biosignals","Machine learning","Multimodal","Stroke volume","Cardiac output","Blood pressure","Congenital heart disease","Hypertension"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/70086"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hemodynamic parameters such as blood pressure and stroke volume are instrumental to understanding the pathogenesis of cardiovascular disease. Unfortunately, the monitoring of these hemodynamic parameters is still limited to in-clinic measurements and cumbersome hardware precludes convenient, ubiquitous use. To address this burden, in this work, we explore seismocardiogram-based wearable multimodal sensing techniques to estimate blood pressure and stroke volume. First, the performance of a multimodal, wrist-worn device capable of obtaining noninvasive pulse transit time measurements is used to estimate blood pressure in an unsupervised, at-home setting. Second, the feasibility of this wrist-worn device is comprehensively evaluated in a diverse and medically underserved population over the course of several perturbations used to modulate blood pressure through different pathways. Finally, the ability of wearable signals—acquired from a custom chest-worn biosensor—to noninvasively quantify stroke volume in patients with congenital heart disease is examined in a hospital setting. Collectively, this work demonstrates the advancements necessary towards enabling noninvasive, longitudinal, and accurate measurements of these hemodynamic parameters in remote settings, which offers to improve health equity and disease monitoring in low-resource settings."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Enabling Wearable Hemodynamic Monitoring Using Multimodal Cardiomechanical Sensing Systems"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Inan, Omer T."],"dc:contributor.committeemember":["Frakes, David H.","Kamaleswaran, Rishikesan","Hahn, Jin-Oh","Tandon, Animesh"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["School of Electrical and Computer Engineering","College of Engineering"],"dc:creator":["Ganti, Venu G."],"dc:date.accessioned":["2023-01-10T16:20:57Z"],"dc:date.available":["2023-01-10T16:20:57Z"],"dc:date.created":["2021-12"],"dc:date.issued":["2021-12-14"],"dc:date.submitted":["December 2021"],"dc:date.updated":["2023-01-10T16:20:57Z"],"dc:description.abstract":["Hemodynamic parameters such as blood pressure and stroke volume are instrumental to understanding the pathogenesis of cardiovascular disease. Unfortunately, the monitoring of these hemodynamic parameters is still limited to in-clinic measurements and cumbersome hardware precludes convenient, ubiquitous use. To address this burden, in this work, we explore seismocardiogram-based wearable multimodal sensing techniques to estimate blood pressure and stroke volume. First, the performance of a multimodal, wrist-worn device capable of obtaining noninvasive pulse transit time measurements is used to estimate blood pressure in an unsupervised, at-home setting. Second, the feasibility of this wrist-worn device is comprehensively evaluated in a diverse and medically underserved population over the course of several perturbations used to modulate blood pressure through different pathways. Finally, the ability of wearable signals—acquired from a custom chest-worn biosensor—to noninvasively quantify stroke volume in patients with congenital heart disease is examined in a hospital setting. Collectively, this work demonstrates the advancements necessary towards enabling noninvasive, longitudinal, and accurate measurements of these hemodynamic parameters in remote settings, which offers to improve health equity and disease monitoring in low-resource settings."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/70086"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["fb82ce90-ad3a-45a6-b0e2-f1ee6fe6f744"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Bioengineering"],"dc:relation.orgunit":["5b7adef2-447c-4270-b9fc-846bd76f80f2","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["5db25cda-aa52-48d2-8f63-c551ef2c92f4"],"dc:subject":["Wearables","Noninvasive","Cardiovascular, Seismocardiogram","Photoplethysmogram","Biosignals","Machine learning","Multimodal","Stroke volume","Cardiac output","Blood pressure","Congenital heart disease","Hypertension"],"dc:title":["Enabling Wearable Hemodynamic Monitoring Using Multimodal Cardiomechanical Sensing Systems"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:14:04Z"}