{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/7136"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/7136","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Development of the Full Height Truss Frame","abstract":"The full height truss frame (FHTF) is an exciting new residential framing system in response to the need for low floor-to-floor steel construction. The FHTF has the potential to provide low floor-to-floor heights, a column free first floor area, an integrated frame that uses the entire height to resist loads, and the capacity to resist both gravity and lateral loads. Because of its configuration, the full structural height can be used to resist loads. A FHTF is made up of stacked floor trusses that result in one full height truss spanning the entire width of the building. The FHTF is constructed in a conventional manner one floor at a time. The strength, inertia, and truss height will increase as each floor is added. Therefore, the construction sequence will affect the final stresses in the members. The purpose of this thesis was to analyze and design two prototype FHTFs, to compare the economy of the prototypes with similar staggered truss frames, and to develop an approximate method to calculate staged member stresses. Each prototype was analyzed using a computer program and designed according to the 2001 American Institute of Steel Construction Load and Resistance Factor Design. The prototypes were used to assess the strength and serviceability of the structures, and the results of the staged analysis were used to validate the numerical method developed to approximate a staged loading sequence based on the non-staged dead load results. The results of the analysis and design of the prototypes was the initial step in confirming the viability of the FHTF for use in the residential multistory market. FHTFs can be designed with preexisting procedure, and are capable of offering low floor-to-floor heights. The prototypes exhibited excellent lateral stiffness against wind loads. The numerical method for estimating the staged dead load accurately approximated the results of the analysis preformed by ETABS. The numerical method can be used to simulate a variety of sequences in order to optimize the stages. Lastly, the FHTF was shown to be competitive with the staggered truss systems in terms of material usage, fabrication, and construction.","abstract_html":"The full height truss frame (FHTF) is an exciting new residential framing system in response to the need for low floor-to-floor steel construction. The FHTF has the potential to provide low floor-to-floor heights, a column free first floor area, an integrated frame that uses the entire height to resist loads, and the capacity to resist both gravity and lateral loads. Because of its configuration, the full structural height can be used to resist loads. A FHTF is made up of stacked floor trusses that result in one full height truss spanning the entire width of the building. The FHTF is constructed in a conventional manner one floor at a time. The strength, inertia, and truss height will increase as each floor is added. Therefore, the construction sequence will affect the final stresses in the members. The purpose of this thesis was to analyze and design two prototype FHTFs, to compare the economy of the prototypes with similar staggered truss frames, and to develop an approximate method to calculate staged member stresses. Each prototype was analyzed using a computer program and designed according to the 2001 American Institute of Steel Construction Load and Resistance Factor Design. The prototypes were used to assess the strength and serviceability of the structures, and the results of the staged analysis were used to validate the numerical method developed to approximate a staged loading sequence based on the non-staged dead load results. The results of the analysis and design of the prototypes was the initial step in confirming the viability of the FHTF for use in the residential multistory market. FHTFs can be designed with preexisting procedure, and are capable of offering low floor-to-floor heights. The prototypes exhibited excellent lateral stiffness against wind loads. The numerical method for estimating the staged dead load accurately approximated the results of the analysis preformed by ETABS. The numerical method can be used to simulate a variety of sequences in order to optimize the stages. Lastly, the FHTF was shown to be competitive with the staggered truss systems in terms of material usage, fabrication, and construction.","abstract_has_math":false,"creators":["Gordon, Joel Christopher"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Lindsey, Stanley D."],"committee_chairs":[],"committee_members":["David Scott","Leon, Roberto T."],"year":2005,"date_issued":"2005-05-20","date_published":"2005-05-20","updated_at":"2026-11-19T06:05:38Z","subjects":["Residential construction","Sequential analysis","Staged analysis","Steel framing systems"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/7136","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/7136","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F7136","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lindsey, Stanley D."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["David Scott","Leon, Roberto T."]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Gordon, Joel Christopher"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-09-16T15:02:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-09-16T15:02:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-05-20"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Civil Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["451ac1ce-0dd6-43a5-8843-bae81fd68e33"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Residential construction","Sequential analysis","Staged analysis","Steel framing systems"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/7136"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The full height truss frame (FHTF) is an exciting new residential framing system in response to the need for low floor-to-floor steel construction. The FHTF has the potential to provide low floor-to-floor heights, a column free first floor area, an integrated frame that uses the entire height to resist loads, and the capacity to resist both gravity and lateral loads. Because of its configuration, the full structural height can be used to resist loads. A FHTF is made up of stacked floor trusses that result in one full height truss spanning the entire width of the building. The FHTF is constructed in a conventional manner one floor at a time. The strength, inertia, and truss height will increase as each floor is added. Therefore, the construction sequence will affect the final stresses in the members. The purpose of this thesis was to analyze and design two prototype FHTFs, to compare the economy of the prototypes with similar staggered truss frames, and to develop an approximate method to calculate staged member stresses. Each prototype was analyzed using a computer program and designed according to the 2001 American Institute of Steel Construction Load and Resistance Factor Design. The prototypes were used to assess the strength and serviceability of the structures, and the results of the staged analysis were used to validate the numerical method developed to approximate a staged loading sequence based on the non-staged dead load results. The results of the analysis and design of the prototypes was the initial step in confirming the viability of the FHTF for use in the residential multistory market. FHTFs can be designed with preexisting procedure, and are capable of offering low floor-to-floor heights. The prototypes exhibited excellent lateral stiffness against wind loads. The numerical method for estimating the staged dead load accurately approximated the results of the analysis preformed by ETABS. The numerical method can be used to simulate a variety of sequences in order to optimize the stages. Lastly, the FHTF was shown to be competitive with the staggered truss systems in terms of material usage, fabrication, and construction."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["2566571 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of the Full Height Truss Frame"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lindsey, Stanley D."],"dc:contributor.committeemember":["David Scott","Leon, Roberto T."],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Gordon, Joel Christopher"],"dc:date.accessioned":["2005-09-16T15:02:00Z"],"dc:date.available":["2005-09-16T15:02:00Z"],"dc:date.issued":["2005-05-20"],"dc:description.abstract":["The full height truss frame (FHTF) is an exciting new residential framing system in response to the need for low floor-to-floor steel construction. The FHTF has the potential to provide low floor-to-floor heights, a column free first floor area, an integrated frame that uses the entire height to resist loads, and the capacity to resist both gravity and lateral loads. Because of its configuration, the full structural height can be used to resist loads. A FHTF is made up of stacked floor trusses that result in one full height truss spanning the entire width of the building. The FHTF is constructed in a conventional manner one floor at a time. The strength, inertia, and truss height will increase as each floor is added. Therefore, the construction sequence will affect the final stresses in the members. The purpose of this thesis was to analyze and design two prototype FHTFs, to compare the economy of the prototypes with similar staggered truss frames, and to develop an approximate method to calculate staged member stresses. Each prototype was analyzed using a computer program and designed according to the 2001 American Institute of Steel Construction Load and Resistance Factor Design. The prototypes were used to assess the strength and serviceability of the structures, and the results of the staged analysis were used to validate the numerical method developed to approximate a staged loading sequence based on the non-staged dead load results. The results of the analysis and design of the prototypes was the initial step in confirming the viability of the FHTF for use in the residential multistory market. FHTFs can be designed with preexisting procedure, and are capable of offering low floor-to-floor heights. The prototypes exhibited excellent lateral stiffness against wind loads. The numerical method for estimating the staged dead load accurately approximated the results of the analysis preformed by ETABS. The numerical method can be used to simulate a variety of sequences in order to optimize the stages. Lastly, the FHTF was shown to be competitive with the staggered truss systems in terms of material usage, fabrication, and construction."],"dc:description.degree":["M.S."],"dc:format.extent":["2566571 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/7136"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Master of Science in Civil Engineering"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["451ac1ce-0dd6-43a5-8843-bae81fd68e33"],"dc:subject":["Residential construction","Sequential analysis","Staged analysis","Steel framing systems"],"dc:title":["Development of the Full Height Truss Frame"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T06:05:38Z"}