{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/7153"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/7153","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Time-Dependent Neutron and Photon Dose-Field Analysis","abstract":"A unique tool is developed that allows the user to model physical representations of complicated glovebox facilities in two dimensions and determine neutral-particle flux and ambient dose-equivalent fields throughout that geometry. The code Pandemonium, originally designed to determine flux and dose rates only, has been improved to include realistic glovebox geometries, time-dependent source and detector positions, time-dependent shielding thickness calculations, time-integrated doses, a representative criticality accident scenario based on time-dependent reactor kinetics, and more rigorous photon treatment. The photon model has been significantly enhanced by expanding the energy range to 10 MeV to include fission photons, and by including a set of new buildup factors, the result of an extensive study into the previously unknown \"purely-angular effect\" on photon buildup. Purely-angular photon buildup factors are determined using discrete ordinates and coupled electron-photon cross sections to account for coherent and incoherent scattering and secondary photon effects of bremsstrahlung and florescence. Improvements to Pandemonium result in significant modeling capabilities for processing facilities using intense neutron and photon sources, and the code obtains comparable results to Monte Carlo calculations but within a fraction of the time required to run such codes as MCNPX.","abstract_html":"A unique tool is developed that allows the user to model physical representations of complicated glovebox facilities in two dimensions and determine neutral-particle flux and ambient dose-equivalent fields throughout that geometry. The code Pandemonium, originally designed to determine flux and dose rates only, has been improved to include realistic glovebox geometries, time-dependent source and detector positions, time-dependent shielding thickness calculations, time-integrated doses, a representative criticality accident scenario based on time-dependent reactor kinetics, and more rigorous photon treatment. The photon model has been significantly enhanced by expanding the energy range to 10 MeV to include fission photons, and by including a set of new buildup factors, the result of an extensive study into the previously unknown &quot;purely-angular effect&quot; on photon buildup. Purely-angular photon buildup factors are determined using discrete ordinates and coupled electron-photon cross sections to account for coherent and incoherent scattering and secondary photon effects of bremsstrahlung and florescence. Improvements to Pandemonium result in significant modeling capabilities for processing facilities using intense neutron and photon sources, and the code obtains comparable results to Monte Carlo calculations but within a fraction of the time required to run such codes as MCNPX.","abstract_has_math":false,"creators":["Wooten, Hasani Omar"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Nuclear and Radiological Engineering","school":null,"contributors":[],"advisors":["Hertel, Nolan E."],"committee_chairs":[],"committee_members":["Wang, C. K. Chris","Donald J. Dudziak","ew E. Kornreich","Eva K. Lee","Karam, Ratib A."],"year":2005,"date_issued":"2005-06-24","date_published":"2005-06-24","updated_at":"2026-11-19T05:57:36Z","subjects":["Health physics","Photon","Dose","Dose rate","Neutron","Photons Measurement","Medical physics","Radioactivity Safety measures","Radiation dosimetry","Neutrons Measurement"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/7153","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/7153","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F7153","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hertel, Nolan E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wang, C. K. Chris","Donald J. Dudziak","ew E. Kornreich","Eva K. Lee","Karam, Ratib A."]},{"key":"dc:contributor.department","label":"Department","values":["Nuclear and Radiological Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Wooten, Hasani Omar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-09-16T15:04:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-09-16T15:04:07Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-06-24"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["26003284-0ae0-4887-a127-917eb8923925"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health physics","Photon","Dose","Dose rate","Neutron"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Photons Measurement","Medical physics","Radioactivity Safety measures","Radiation dosimetry","Neutrons Measurement"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/7153"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A unique tool is developed that allows the user to model physical representations of complicated glovebox facilities in two dimensions and determine neutral-particle flux and ambient dose-equivalent fields throughout that geometry. The code Pandemonium, originally designed to determine flux and dose rates only, has been improved to include realistic glovebox geometries, time-dependent source and detector positions, time-dependent shielding thickness calculations, time-integrated doses, a representative criticality accident scenario based on time-dependent reactor kinetics, and more rigorous photon treatment. The photon model has been significantly enhanced by expanding the energy range to 10 MeV to include fission photons, and by including a set of new buildup factors, the result of an extensive study into the previously unknown \"purely-angular effect\" on photon buildup. Purely-angular photon buildup factors are determined using discrete ordinates and coupled electron-photon cross sections to account for coherent and incoherent scattering and secondary photon effects of bremsstrahlung and florescence. Improvements to Pandemonium result in significant modeling capabilities for processing facilities using intense neutron and photon sources, and the code obtains comparable results to Monte Carlo calculations but within a fraction of the time required to run such codes as MCNPX."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["1583443 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Time-Dependent Neutron and Photon Dose-Field Analysis"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hertel, Nolan E."],"dc:contributor.committeemember":["Wang, C. K. Chris","Donald J. Dudziak","ew E. Kornreich","Eva K. Lee","Karam, Ratib A."],"dc:contributor.department":["Nuclear and Radiological Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Wooten, Hasani Omar"],"dc:date.accessioned":["2005-09-16T15:04:07Z"],"dc:date.available":["2005-09-16T15:04:07Z"],"dc:date.issued":["2005-06-24"],"dc:description.abstract":["A unique tool is developed that allows the user to model physical representations of complicated glovebox facilities in two dimensions and determine neutral-particle flux and ambient dose-equivalent fields throughout that geometry. The code Pandemonium, originally designed to determine flux and dose rates only, has been improved to include realistic glovebox geometries, time-dependent source and detector positions, time-dependent shielding thickness calculations, time-integrated doses, a representative criticality accident scenario based on time-dependent reactor kinetics, and more rigorous photon treatment. The photon model has been significantly enhanced by expanding the energy range to 10 MeV to include fission photons, and by including a set of new buildup factors, the result of an extensive study into the previously unknown \"purely-angular effect\" on photon buildup. Purely-angular photon buildup factors are determined using discrete ordinates and coupled electron-photon cross sections to account for coherent and incoherent scattering and secondary photon effects of bremsstrahlung and florescence. Improvements to Pandemonium result in significant modeling capabilities for processing facilities using intense neutron and photon sources, and the code obtains comparable results to Monte Carlo calculations but within a fraction of the time required to run such codes as MCNPX."],"dc:description.degree":["Ph.D."],"dc:format.extent":["1583443 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/7153"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["26003284-0ae0-4887-a127-917eb8923925"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Nuclear Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"],"dc:subject":["Health physics","Photon","Dose","Dose rate","Neutron"],"dc:subject.lcsh":["Photons Measurement","Medical physics","Radioactivity Safety measures","Radiation dosimetry","Neutrons Measurement"],"dc:title":["Time-Dependent Neutron and Photon Dose-Field Analysis"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:57:36Z"}