{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/7154"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/7154","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Novel Pervaporation for Separating Acetic Acid and Water Mixtures Using Hollow Fiber Membranes","abstract":"Commercial pure terephthalic acid (PTA) manufacturing generates process streams mainly containing acetic acid (HAc) and water. A large financial incentive exists to replace the costly and energy intensive distillation column used to recycle HAc-water mixtures. This work focuses on the development of pervaporation technology to separate HAc-water mixtures using a hollow fiber-based membrane unit. Currently a 250 m outer diameter Matrimid® hollow fiber is used in industry for gas separation. Due to the difference between gas and liquid separations, the fiber performance associated with high flux in pervaporation is limited by a pressure change inside the bore along the axial direction of the fiber. A mathematical model was developed to describe the bore pressure change in pervaporation in this work, which demonstrated that spinning a large bore size fiber was a good solution to minimize the bore pressure change. Spinning technology has been adapted to obtain a large bore size defect-free Matrimid® hollow fiber. In addition to a large bore size, the asymmetric fiber exhibits an intrinsically defect-free selective layer supported on an open porous substrate. This eliminates the post-treatment with a caulking layer and has a special advantage for aggressive liquid separation. A proof of concept was provided by testing both small and large bore size defect-free fibers with a model 20% wt HAc feed in a pervaporation system at 101.5oC. The membrane selectivity (~ 25) and water flux (~ 4.5 kg/m2hr) were increased by about 150% with a diameter (O.D. ~ 500 m) twice as large as the regular fiber. Further, a decrease in the HAc flux was observed with the increased bore size due to the reduction in HAc-induced plasticization. Sub-Tg thermal annealing was used to stabilize the fiber by suppressing HAc-induced plasticization. This improves the polymer discrimination of shape and size for penetrants although no chemical reaction occurs with thermal annealing. The resulting membrane selectivity was increased from 10 to about 95 using a large bore size defect-free annealed fiber with acceptable water flux (~ 1.5 kg/m2hr) for 20% wt HAc concentration feed streams. These improvements make Matrimid® hollow fiber membranes very attractive for future scale-up and commercial development.","abstract_html":"Commercial pure terephthalic acid (PTA) manufacturing generates process streams mainly containing acetic acid (HAc) and water. A large financial incentive exists to replace the costly and energy intensive distillation column used to recycle HAc-water mixtures. This work focuses on the development of pervaporation technology to separate HAc-water mixtures using a hollow fiber-based membrane unit. Currently a 250 m outer diameter Matrimid® hollow fiber is used in industry for gas separation. Due to the difference between gas and liquid separations, the fiber performance associated with high flux in pervaporation is limited by a pressure change inside the bore along the axial direction of the fiber. A mathematical model was developed to describe the bore pressure change in pervaporation in this work, which demonstrated that spinning a large bore size fiber was a good solution to minimize the bore pressure change. Spinning technology has been adapted to obtain a large bore size defect-free Matrimid® hollow fiber. In addition to a large bore size, the asymmetric fiber exhibits an intrinsically defect-free selective layer supported on an open porous substrate. This eliminates the post-treatment with a caulking layer and has a special advantage for aggressive liquid separation. A proof of concept was provided by testing both small and large bore size defect-free fibers with a model 20% wt HAc feed in a pervaporation system at 101.5oC. The membrane selectivity (~ 25) and water flux (~ 4.5 kg/m2hr) were increased by about 150% with a diameter (O.D. ~ 500 m) twice as large as the regular fiber. Further, a decrease in the HAc flux was observed with the increased bore size due to the reduction in HAc-induced plasticization. Sub-Tg thermal annealing was used to stabilize the fiber by suppressing HAc-induced plasticization. This improves the polymer discrimination of shape and size for penetrants although no chemical reaction occurs with thermal annealing. The resulting membrane selectivity was increased from 10 to about 95 using a large bore size defect-free annealed fiber with acceptable water flux (~ 1.5 kg/m2hr) for 20% wt HAc concentration feed streams. These improvements make Matrimid® hollow fiber membranes very attractive for future scale-up and commercial development.","abstract_has_math":false,"creators":["Zhou, Fangbin"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Chemical Engineering","school":null,"contributors":[],"advisors":["Koros, William J."],"committee_chairs":[],"committee_members":["Carr, Wallace","Eckert, Charles A.","Pietsch, Stephen","Schork, F. Joseph","Teja, Amyn"],"year":2005,"date_issued":"2005-06-27","date_published":"2005-06-27","updated_at":"2026-11-19T05:49:53Z","subjects":["Matrimid® pervaporation","Membranes (Technology)","Pervaporation Mathematical models","Hollow fiber membrane","Acetic acid","Filters and filtration","Plasticization","Thermal annealing"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/7154","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/7154","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F7154","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Koros, William J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Carr, Wallace","Eckert, Charles A.","Pietsch, Stephen","Schork, F. Joseph","Teja, Amyn"]},{"key":"dc:contributor.department","label":"Department","values":["Chemical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Chemical and Biomolecular Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Zhou, Fangbin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-09-16T15:04:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-09-16T15:04:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-06-27"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["0059291f-6b5a-4a6c-a661-eef665ac3a18"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Chemical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["6cfa2dc6-c5bf-4f6b-99a2-57105d8f7a6f","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["ea697a63-dfa6-4bfb-b0eb-38b9587437ee"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Matrimid® pervaporation","Membranes (Technology)","Pervaporation Mathematical models","Hollow fiber membrane","Acetic acid","Filters and filtration","Plasticization","Thermal annealing"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Pervaporation Mathematical models","Membranes (Technology)","Filters and filtration","Acetic acid"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/7154"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Commercial pure terephthalic acid (PTA) manufacturing generates process streams mainly containing acetic acid (HAc) and water. A large financial incentive exists to replace the costly and energy intensive distillation column used to recycle HAc-water mixtures. This work focuses on the development of pervaporation technology to separate HAc-water mixtures using a hollow fiber-based membrane unit. Currently a 250 m outer diameter Matrimid® hollow fiber is used in industry for gas separation. Due to the difference between gas and liquid separations, the fiber performance associated with high flux in pervaporation is limited by a pressure change inside the bore along the axial direction of the fiber. A mathematical model was developed to describe the bore pressure change in pervaporation in this work, which demonstrated that spinning a large bore size fiber was a good solution to minimize the bore pressure change. Spinning technology has been adapted to obtain a large bore size defect-free Matrimid® hollow fiber. In addition to a large bore size, the asymmetric fiber exhibits an intrinsically defect-free selective layer supported on an open porous substrate. This eliminates the post-treatment with a caulking layer and has a special advantage for aggressive liquid separation. A proof of concept was provided by testing both small and large bore size defect-free fibers with a model 20% wt HAc feed in a pervaporation system at 101.5oC. The membrane selectivity (~ 25) and water flux (~ 4.5 kg/m2hr) were increased by about 150% with a diameter (O.D. ~ 500 m) twice as large as the regular fiber. Further, a decrease in the HAc flux was observed with the increased bore size due to the reduction in HAc-induced plasticization. Sub-Tg thermal annealing was used to stabilize the fiber by suppressing HAc-induced plasticization. This improves the polymer discrimination of shape and size for penetrants although no chemical reaction occurs with thermal annealing. The resulting membrane selectivity was increased from 10 to about 95 using a large bore size defect-free annealed fiber with acceptable water flux (~ 1.5 kg/m2hr) for 20% wt HAc concentration feed streams. These improvements make Matrimid® hollow fiber membranes very attractive for future scale-up and commercial development."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["1494970 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Novel Pervaporation for Separating Acetic Acid and Water Mixtures Using Hollow Fiber Membranes"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Koros, William J."],"dc:contributor.committeemember":["Carr, Wallace","Eckert, Charles A.","Pietsch, Stephen","Schork, F. Joseph","Teja, Amyn"],"dc:contributor.department":["Chemical Engineering"],"dc:contributor.other":["School of Chemical and Biomolecular Engineering","College of Engineering"],"dc:creator":["Zhou, Fangbin"],"dc:date.accessioned":["2005-09-16T15:04:13Z"],"dc:date.available":["2005-09-16T15:04:13Z"],"dc:date.issued":["2005-06-27"],"dc:description.abstract":["Commercial pure terephthalic acid (PTA) manufacturing generates process streams mainly containing acetic acid (HAc) and water. A large financial incentive exists to replace the costly and energy intensive distillation column used to recycle HAc-water mixtures. This work focuses on the development of pervaporation technology to separate HAc-water mixtures using a hollow fiber-based membrane unit. Currently a 250 m outer diameter Matrimid® hollow fiber is used in industry for gas separation. Due to the difference between gas and liquid separations, the fiber performance associated with high flux in pervaporation is limited by a pressure change inside the bore along the axial direction of the fiber. A mathematical model was developed to describe the bore pressure change in pervaporation in this work, which demonstrated that spinning a large bore size fiber was a good solution to minimize the bore pressure change. Spinning technology has been adapted to obtain a large bore size defect-free Matrimid® hollow fiber. In addition to a large bore size, the asymmetric fiber exhibits an intrinsically defect-free selective layer supported on an open porous substrate. This eliminates the post-treatment with a caulking layer and has a special advantage for aggressive liquid separation. A proof of concept was provided by testing both small and large bore size defect-free fibers with a model 20% wt HAc feed in a pervaporation system at 101.5oC. The membrane selectivity (~ 25) and water flux (~ 4.5 kg/m2hr) were increased by about 150% with a diameter (O.D. ~ 500 m) twice as large as the regular fiber. Further, a decrease in the HAc flux was observed with the increased bore size due to the reduction in HAc-induced plasticization. Sub-Tg thermal annealing was used to stabilize the fiber by suppressing HAc-induced plasticization. This improves the polymer discrimination of shape and size for penetrants although no chemical reaction occurs with thermal annealing. The resulting membrane selectivity was increased from 10 to about 95 using a large bore size defect-free annealed fiber with acceptable water flux (~ 1.5 kg/m2hr) for 20% wt HAc concentration feed streams. These improvements make Matrimid® hollow fiber membranes very attractive for future scale-up and commercial development."],"dc:description.degree":["Ph.D."],"dc:format.extent":["1494970 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/7154"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["0059291f-6b5a-4a6c-a661-eef665ac3a18"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Chemical Engineering"],"dc:relation.orgunit":["6cfa2dc6-c5bf-4f6b-99a2-57105d8f7a6f","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["ea697a63-dfa6-4bfb-b0eb-38b9587437ee"],"dc:subject":["Matrimid® pervaporation","Membranes (Technology)","Pervaporation Mathematical models","Hollow fiber membrane","Acetic acid","Filters and filtration","Plasticization","Thermal annealing"],"dc:subject.lcsh":["Pervaporation Mathematical models","Membranes (Technology)","Filters and filtration","Acetic acid"],"dc:title":["Novel Pervaporation for Separating Acetic Acid and Water Mixtures Using Hollow Fiber Membranes"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:49:53Z"}