{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/7187"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/7187","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Influence of Creep on the Stability of Pultruded E-Glass/Polyester Composite Columns at Elevated Service Temperatures","abstract":"This study is an experimental investigation pertaining to the creep behavior of slender pultruded fiber-reinforced polymeric (FRP) columns subjected to sustained concentric axial loading at elevated service temperatures. Six creep tests were performed on columns having a slenderness ratio of 49 at different combinations of axial load and temperature for a duration of at least 1,000 hours. The axial loads used represented 33%, 67%, and 90% of the critical buckling load for the column selected. For each load level, one test was performed at 22.8℃ (73℉) and one test was performed at 65.5℃ (150℉) Knife-edge end supports were utilized to simulate pinned-pinned boundary conditions. Midheight lateral deflection and axial shortening were recorded incrementally for the duration of the testing. Following termination of the creep tests, the columns were allowed to recover and tested for buckling strength. A semi-empirical model for long-term behavior of concentrically loaded FRP columns at elevated service temperatures is proposed based on experimental results.","abstract_html":"This study is an experimental investigation pertaining to the creep behavior of slender pultruded fiber-reinforced polymeric (FRP) columns subjected to sustained concentric axial loading at elevated service temperatures. Six creep tests were performed on columns having a slenderness ratio of 49 at different combinations of axial load and temperature for a duration of at least 1,000 hours. The axial loads used represented 33%, 67%, and 90% of the critical buckling load for the column selected. For each load level, one test was performed at 22.8℃ (73℉) and one test was performed at 65.5℃ (150℉) Knife-edge end supports were utilized to simulate pinned-pinned boundary conditions. Midheight lateral deflection and axial shortening were recorded incrementally for the duration of the testing. Following termination of the creep tests, the columns were allowed to recover and tested for buckling strength. A semi-empirical model for long-term behavior of concentrically loaded FRP columns at elevated service temperatures is proposed based on experimental results.","abstract_has_math":false,"creators":["Bennett, Evan A."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Scott, David W."],"committee_chairs":[],"committee_members":["Haj-Ali, Rami","Lindsey, Stanley"],"year":2005,"date_issued":"2005-07-18","date_published":"2005-07-18","updated_at":"2026-11-19T05:55:05Z","subjects":["Creep","Columns","Pultruded","Temperature"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/7187","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/7187","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F7187","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Scott, David W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Haj-Ali, Rami","Lindsey, Stanley"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["School of Civil and Environmental Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Bennett, Evan A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-09-16T15:08:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-09-16T15:08:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-07-18"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["58fcfcfe-cc5d-452b-9016-ff0bf3434aa2"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Civil Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["451ac1ce-0dd6-43a5-8843-bae81fd68e33"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Creep","Columns","Pultruded","Temperature"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/7187"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study is an experimental investigation pertaining to the creep behavior of slender pultruded fiber-reinforced polymeric (FRP) columns subjected to sustained concentric axial loading at elevated service temperatures. Six creep tests were performed on columns having a slenderness ratio of 49 at different combinations of axial load and temperature for a duration of at least 1,000 hours. The axial loads used represented 33%, 67%, and 90% of the critical buckling load for the column selected. For each load level, one test was performed at 22.8℃ (73℉) and one test was performed at 65.5℃ (150℉) Knife-edge end supports were utilized to simulate pinned-pinned boundary conditions. Midheight lateral deflection and axial shortening were recorded incrementally for the duration of the testing. Following termination of the creep tests, the columns were allowed to recover and tested for buckling strength. A semi-empirical model for long-term behavior of concentrically loaded FRP columns at elevated service temperatures is proposed based on experimental results."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["1266599 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Influence of Creep on the Stability of Pultruded E-Glass/Polyester Composite Columns at Elevated Service Temperatures"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Scott, David W."],"dc:contributor.committeemember":["Haj-Ali, Rami","Lindsey, Stanley"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["School of Civil and Environmental Engineering","College of Engineering"],"dc:creator":["Bennett, Evan A."],"dc:date.accessioned":["2005-09-16T15:08:37Z"],"dc:date.available":["2005-09-16T15:08:37Z"],"dc:date.issued":["2005-07-18"],"dc:description.abstract":["This study is an experimental investigation pertaining to the creep behavior of slender pultruded fiber-reinforced polymeric (FRP) columns subjected to sustained concentric axial loading at elevated service temperatures. Six creep tests were performed on columns having a slenderness ratio of 49 at different combinations of axial load and temperature for a duration of at least 1,000 hours. The axial loads used represented 33%, 67%, and 90% of the critical buckling load for the column selected. For each load level, one test was performed at 22.8℃ (73℉) and one test was performed at 65.5℃ (150℉) Knife-edge end supports were utilized to simulate pinned-pinned boundary conditions. Midheight lateral deflection and axial shortening were recorded incrementally for the duration of the testing. Following termination of the creep tests, the columns were allowed to recover and tested for buckling strength. A semi-empirical model for long-term behavior of concentrically loaded FRP columns at elevated service temperatures is proposed based on experimental results."],"dc:description.degree":["M.S."],"dc:format.extent":["1266599 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/7187"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["58fcfcfe-cc5d-452b-9016-ff0bf3434aa2"],"dc:relation.ispartofseries":["Master of Science in Civil Engineering"],"dc:relation.orgunit":["88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["451ac1ce-0dd6-43a5-8843-bae81fd68e33"],"dc:subject":["Creep","Columns","Pultruded","Temperature"],"dc:title":["Influence of Creep on the Stability of Pultruded E-Glass/Polyester Composite Columns at Elevated Service Temperatures"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:55:05Z"}