{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/72047"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/72047","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Delamination-based Control of Capillary Flow for Physically Programmed Lateral Flow Assays","abstract":"LFAs utilize the capillary flow of liquids for simple detection of analytes. While useful for spontaneously wicking samples, the capillary flow inherently limits performing complex reactions that require the timely application of multiple solutions. In this thesis, we introduce a new technique to control capillary flow on paper by simply imprinting roadblocks on the flow path with water-insoluble ink and utilizing the gradual formation of a void between a wetted paper and a sheath polymer tape to create timers. Timers are drawn at strategic nodes to hold the capillary flow for the desired period and thereby enable multiple liquids to be introduced into multi-step chemical reactions following a programmed sequence. The ability to sequentially deliver different reagents into a reaction via programmable timers imprinted on paper makes it possible to automate multi-step assays, that otherwise could only be performed in laboratories or with manual intervention. Using our technique, we have developed multiple POC diagnostic devices to convert the current COVID-19 assays into POC form factors, such as (1) chemically amplified multiplex antigen test of SARS-CoV-2, influenza A, and B viruses in saliva, (2) paper-based dipstick ELISA that reports SARS-CoV-2 antibody titers in a digital manner without the need for an external instrument or operator, and (3) POC toolkit for multiplex molecular diagnosis of SARS-CoV-2 and influenza A & B viruses from saliva.","abstract_html":"LFAs utilize the capillary flow of liquids for simple detection of analytes. While useful for spontaneously wicking samples, the capillary flow inherently limits performing complex reactions that require the timely application of multiple solutions. In this thesis, we introduce a new technique to control capillary flow on paper by simply imprinting roadblocks on the flow path with water-insoluble ink and utilizing the gradual formation of a void between a wetted paper and a sheath polymer tape to create timers. Timers are drawn at strategic nodes to hold the capillary flow for the desired period and thereby enable multiple liquids to be introduced into multi-step chemical reactions following a programmed sequence. The ability to sequentially deliver different reagents into a reaction via programmable timers imprinted on paper makes it possible to automate multi-step assays, that otherwise could only be performed in laboratories or with manual intervention. Using our technique, we have developed multiple POC diagnostic devices to convert the current COVID-19 assays into POC form factors, such as (1) chemically amplified multiplex antigen test of SARS-CoV-2, influenza A, and B viruses in saliva, (2) paper-based dipstick ELISA that reports SARS-CoV-2 antibody titers in a digital manner without the need for an external instrument or operator, and (3) POC toolkit for multiplex molecular diagnosis of SARS-CoV-2 and influenza A &amp; B viruses from saliva.","abstract_has_math":false,"creators":["Lee, Dohwan"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Sarioglu, A. Fatih"],"committee_chairs":[],"committee_members":["Frazier, Albert B.","Emelianov, Stanislav","Styczynski, Mark P.","Bhatti, Pamela T."],"year":2023,"date_issued":"2023-04-26","date_published":"2023-04-26","updated_at":"2026-11-19T05:04:47Z","subjects":["Point-of-care testing","Capillary flow control","Paper-based microfluidics","Lateral flow assays","COVID-19 assays"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/72047","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/72047","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F72047","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sarioglu, A. Fatih"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Frazier, Albert B.","Emelianov, Stanislav","Styczynski, Mark P.","Bhatti, Pamela T."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Lee, Dohwan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-05-18T17:54:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-05-18T17:54:42Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-05"]},{"key":"dc:date.issued","label":"Date","values":["2023-04-26"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2023-05-18T17:54:42Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["a663fb68-17d4-4b9e-9342-a9fde343991e"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Point-of-care testing","Capillary flow control","Paper-based microfluidics","Lateral flow assays","COVID-19 assays"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/72047"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Per graduate office, item removed from repository, to be reinstated May 2025"]},{"key":"dc:description.abstract","label":"Abstract","values":["LFAs utilize the capillary flow of liquids for simple detection of analytes. While useful for spontaneously wicking samples, the capillary flow inherently limits performing complex reactions that require the timely application of multiple solutions. In this thesis, we introduce a new technique to control capillary flow on paper by simply imprinting roadblocks on the flow path with water-insoluble ink and utilizing the gradual formation of a void between a wetted paper and a sheath polymer tape to create timers. Timers are drawn at strategic nodes to hold the capillary flow for the desired period and thereby enable multiple liquids to be introduced into multi-step chemical reactions following a programmed sequence. The ability to sequentially deliver different reagents into a reaction via programmable timers imprinted on paper makes it possible to automate multi-step assays, that otherwise could only be performed in laboratories or with manual intervention. Using our technique, we have developed multiple POC diagnostic devices to convert the current COVID-19 assays into POC form factors, such as (1) chemically amplified multiplex antigen test of SARS-CoV-2, influenza A, and B viruses in saliva, (2) paper-based dipstick ELISA that reports SARS-CoV-2 antibody titers in a digital manner without the need for an external instrument or operator, and (3) POC toolkit for multiplex molecular diagnosis of SARS-CoV-2 and influenza A & B viruses from saliva."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Delamination-based Control of Capillary Flow for Physically Programmed Lateral Flow Assays"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sarioglu, A. Fatih"],"dc:contributor.committeemember":["Frazier, Albert B.","Emelianov, Stanislav","Styczynski, Mark P.","Bhatti, Pamela T."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["College of Engineering","School of Electrical and Computer Engineering"],"dc:creator":["Lee, Dohwan"],"dc:date.accessioned":["2023-05-18T17:54:42Z"],"dc:date.available":["2023-05-18T17:54:42Z"],"dc:date.created":["2023-05"],"dc:date.issued":["2023-04-26"],"dc:date.submitted":["May 2023"],"dc:date.updated":["2023-05-18T17:54:42Z"],"dc:description":["Per graduate office, item removed from repository, to be reinstated May 2025"],"dc:description.abstract":["LFAs utilize the capillary flow of liquids for simple detection of analytes. While useful for spontaneously wicking samples, the capillary flow inherently limits performing complex reactions that require the timely application of multiple solutions. In this thesis, we introduce a new technique to control capillary flow on paper by simply imprinting roadblocks on the flow path with water-insoluble ink and utilizing the gradual formation of a void between a wetted paper and a sheath polymer tape to create timers. Timers are drawn at strategic nodes to hold the capillary flow for the desired period and thereby enable multiple liquids to be introduced into multi-step chemical reactions following a programmed sequence. The ability to sequentially deliver different reagents into a reaction via programmable timers imprinted on paper makes it possible to automate multi-step assays, that otherwise could only be performed in laboratories or with manual intervention. Using our technique, we have developed multiple POC diagnostic devices to convert the current COVID-19 assays into POC form factors, such as (1) chemically amplified multiplex antigen test of SARS-CoV-2, influenza A, and B viruses in saliva, (2) paper-based dipstick ELISA that reports SARS-CoV-2 antibody titers in a digital manner without the need for an external instrument or operator, and (3) POC toolkit for multiplex molecular diagnosis of SARS-CoV-2 and influenza A & B viruses from saliva."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/72047"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["a663fb68-17d4-4b9e-9342-a9fde343991e"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Point-of-care testing","Capillary flow control","Paper-based microfluidics","Lateral flow assays","COVID-19 assays"],"dc:title":["Delamination-based Control of Capillary Flow for Physically Programmed Lateral Flow Assays"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:04:47Z"}