{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/72412"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/72412","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Failure mechanism and damage evolution in flexible electronics under axial and twist strains","abstract":"Electronic devices have found use in a variety of flexible form factors and applications such as structural health monitors, wearable human health monitoring devices, and body suits. These form factors expose the electronic components (printed traces, passives, active devices, etc.) to a wide range of mechanical strains that are not typically seen in traditional rigid electronic systems. This is because the utility of the flexible wearable electronic systems depends on their ability to stretch, bend, and twist. With such stretching, bending, and twisting, the electrical conductance and thus, the overall performance of the flexible wearable electronics will change, and a clear understanding of the relationship between applied loading and the evolution of damage as well as the change in electrical properties is lacking. In this work, printed silver conductors on various flexible substrates such as polyimide and polyethylene terephthalate are subjected to both monotonic and cyclic stretching while the in-situ DC resistance is monitored. A numerical model based on RVE modeling is developed to provide predictive performance capability. In addition to DC measurements, high-frequency measurements of coplanar wave guides are performed during stretch to understand the behavior of conductors intended for high-frequency applications. Additionally, an innovative test apparatus is designed and fabricated to apply controlled twists to printed samples for both monotonic and fatigue testing. Finally, combinations of simultaneous stretch and twist are applied using another custom test apparatus to conductors to understand resistance change and damage evolution.","abstract_html":"Electronic devices have found use in a variety of flexible form factors and applications such as structural health monitors, wearable human health monitoring devices, and body suits. These form factors expose the electronic components (printed traces, passives, active devices, etc.) to a wide range of mechanical strains that are not typically seen in traditional rigid electronic systems. This is because the utility of the flexible wearable electronic systems depends on their ability to stretch, bend, and twist. With such stretching, bending, and twisting, the electrical conductance and thus, the overall performance of the flexible wearable electronics will change, and a clear understanding of the relationship between applied loading and the evolution of damage as well as the change in electrical properties is lacking. In this work, printed silver conductors on various flexible substrates such as polyimide and polyethylene terephthalate are subjected to both monotonic and cyclic stretching while the in-situ DC resistance is monitored. A numerical model based on RVE modeling is developed to provide predictive performance capability. In addition to DC measurements, high-frequency measurements of coplanar wave guides are performed during stretch to understand the behavior of conductors intended for high-frequency applications. Additionally, an innovative test apparatus is designed and fabricated to apply controlled twists to printed samples for both monotonic and fatigue testing. Finally, combinations of simultaneous stretch and twist are applied using another custom test apparatus to conductors to understand resistance change and damage evolution.","abstract_has_math":false,"creators":["Chow, Justin Hua-Yung"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Sitaraman, Suresh K."],"committee_chairs":[],"committee_members":["Antoniou, Antonia","Jacob, Karl","Swaminathan, Madhavan","Meth, Jeffrey"],"year":2022,"date_issued":"2022-01-14","date_published":"2022-01-14","updated_at":"2026-11-19T06:10:53Z","subjects":["Flexible Electronics","Mechanical Reliability","Failure Prediction"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/72412","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/72412","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F72412","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sitaraman, Suresh K."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Antoniou, Antonia","Jacob, Karl","Swaminathan, Madhavan","Meth, Jeffrey"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Chow, Justin Hua-Yung"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-07-26T18:44:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-07-26T18:44:23Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-05"]},{"key":"dc:date.issued","label":"Date","values":["2022-01-14"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2022"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2023-07-26T18:44:24Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["86701d63-9ca5-4060-89f8-aca6e0b267f6"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Flexible Electronics","Mechanical Reliability","Failure Prediction"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/72412"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Electronic devices have found use in a variety of flexible form factors and applications such as structural health monitors, wearable human health monitoring devices, and body suits. These form factors expose the electronic components (printed traces, passives, active devices, etc.) to a wide range of mechanical strains that are not typically seen in traditional rigid electronic systems. This is because the utility of the flexible wearable electronic systems depends on their ability to stretch, bend, and twist. With such stretching, bending, and twisting, the electrical conductance and thus, the overall performance of the flexible wearable electronics will change, and a clear understanding of the relationship between applied loading and the evolution of damage as well as the change in electrical properties is lacking. In this work, printed silver conductors on various flexible substrates such as polyimide and polyethylene terephthalate are subjected to both monotonic and cyclic stretching while the in-situ DC resistance is monitored. A numerical model based on RVE modeling is developed to provide predictive performance capability. In addition to DC measurements, high-frequency measurements of coplanar wave guides are performed during stretch to understand the behavior of conductors intended for high-frequency applications. Additionally, an innovative test apparatus is designed and fabricated to apply controlled twists to printed samples for both monotonic and fatigue testing. Finally, combinations of simultaneous stretch and twist are applied using another custom test apparatus to conductors to understand resistance change and damage evolution."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Failure mechanism and damage evolution in flexible electronics under axial and twist strains"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sitaraman, Suresh K."],"dc:contributor.committeemember":["Antoniou, Antonia","Jacob, Karl","Swaminathan, Madhavan","Meth, Jeffrey"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Chow, Justin Hua-Yung"],"dc:date.accessioned":["2023-07-26T18:44:23Z"],"dc:date.available":["2023-07-26T18:44:23Z"],"dc:date.created":["2022-05"],"dc:date.issued":["2022-01-14"],"dc:date.submitted":["May 2022"],"dc:date.updated":["2023-07-26T18:44:24Z"],"dc:description.abstract":["Electronic devices have found use in a variety of flexible form factors and applications such as structural health monitors, wearable human health monitoring devices, and body suits. These form factors expose the electronic components (printed traces, passives, active devices, etc.) to a wide range of mechanical strains that are not typically seen in traditional rigid electronic systems. This is because the utility of the flexible wearable electronic systems depends on their ability to stretch, bend, and twist. With such stretching, bending, and twisting, the electrical conductance and thus, the overall performance of the flexible wearable electronics will change, and a clear understanding of the relationship between applied loading and the evolution of damage as well as the change in electrical properties is lacking. In this work, printed silver conductors on various flexible substrates such as polyimide and polyethylene terephthalate are subjected to both monotonic and cyclic stretching while the in-situ DC resistance is monitored. A numerical model based on RVE modeling is developed to provide predictive performance capability. In addition to DC measurements, high-frequency measurements of coplanar wave guides are performed during stretch to understand the behavior of conductors intended for high-frequency applications. Additionally, an innovative test apparatus is designed and fabricated to apply controlled twists to printed samples for both monotonic and fatigue testing. Finally, combinations of simultaneous stretch and twist are applied using another custom test apparatus to conductors to understand resistance change and damage evolution."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/72412"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["86701d63-9ca5-4060-89f8-aca6e0b267f6"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:subject":["Flexible Electronics","Mechanical Reliability","Failure Prediction"],"dc:title":["Failure mechanism and damage evolution in flexible electronics under axial and twist strains"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T06:10:53Z"}