{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/7255"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/7255","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Innovative Thermal Management of Electronics Used in Oil Well Logging","abstract":"The oil and gas industries use sophisticated logging tools during and after drilling. These logging tools employ internal electronics for sensing viscosity, pressure, temperature, and other important quantities. To protect the sensitive electronics, which typically have a maximum allowable temperature of 100 㬠they are shielded and insulated from the harsh external drilling environment. The insulation reduces the external heat input, but it also makes rejection of the heat generated within the electronics challenging. Electronic component failures promoted by elevated temperatures, and thermal stress, require a time consuming and expensive logging tool replacement process. Better thermal management of the electronics in logging tools promises to save oil and gas companies time and money. This research focuses on this critical thermal management challenge. Specifically, this thesis describes the design, fabrication, and test of an innovative thermal management system capable of cooling commercial-off-the-shelf electronics for extended periods in harsh ambient temperatures exceeding 200 㮠Resistive heaters embedded in quad-flat-packages simulate the electronics used in oil well logging. A custom high temperature oven facilitates the evaluation of a full scale prototype of the thermal management system. We anticipate the prototype device will validate computer modeling efforts on which its design was based, and advance future designs of the thermal management system.","abstract_html":"The oil and gas industries use sophisticated logging tools during and after drilling. These logging tools employ internal electronics for sensing viscosity, pressure, temperature, and other important quantities. To protect the sensitive electronics, which typically have a maximum allowable temperature of 100 㬠they are shielded and insulated from the harsh external drilling environment. The insulation reduces the external heat input, but it also makes rejection of the heat generated within the electronics challenging. Electronic component failures promoted by elevated temperatures, and thermal stress, require a time consuming and expensive logging tool replacement process. Better thermal management of the electronics in logging tools promises to save oil and gas companies time and money. This research focuses on this critical thermal management challenge. Specifically, this thesis describes the design, fabrication, and test of an innovative thermal management system capable of cooling commercial-off-the-shelf electronics for extended periods in harsh ambient temperatures exceeding 200 㮠Resistive heaters embedded in quad-flat-packages simulate the electronics used in oil well logging. A custom high temperature oven facilitates the evaluation of a full scale prototype of the thermal management system. We anticipate the prototype device will validate computer modeling efforts on which its design was based, and advance future designs of the thermal management system.","abstract_has_math":false,"creators":["Jakaboski, Juan-Carlos"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Joshi, Yogendra"],"committee_chairs":[],"committee_members":["Bruce Storm","Ghiaasiaan, S. Mostafa"],"year":2004,"date_issued":"2004-05-14","date_published":"2004-05-14","updated_at":"2026-11-19T04:54:43Z","subjects":["Oil well logging","Electronics thermal management"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/7255","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/7255","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F7255","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Joshi, Yogendra"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bruce Storm","Ghiaasiaan, S. Mostafa"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Jakaboski, Juan-Carlos"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-09-16T15:19:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-09-16T15:19:15Z"]},{"key":"dc:date.issued","label":"Date","values":["2004-05-14"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["63ef328b-076b-44b7-92a9-0f7dd03fa1fa"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Oil well logging","Electronics thermal management"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/7255"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The oil and gas industries use sophisticated logging tools during and after drilling. These logging tools employ internal electronics for sensing viscosity, pressure, temperature, and other important quantities. To protect the sensitive electronics, which typically have a maximum allowable temperature of 100 㬠they are shielded and insulated from the harsh external drilling environment. The insulation reduces the external heat input, but it also makes rejection of the heat generated within the electronics challenging. Electronic component failures promoted by elevated temperatures, and thermal stress, require a time consuming and expensive logging tool replacement process. Better thermal management of the electronics in logging tools promises to save oil and gas companies time and money. This research focuses on this critical thermal management challenge. Specifically, this thesis describes the design, fabrication, and test of an innovative thermal management system capable of cooling commercial-off-the-shelf electronics for extended periods in harsh ambient temperatures exceeding 200 㮠Resistive heaters embedded in quad-flat-packages simulate the electronics used in oil well logging. A custom high temperature oven facilitates the evaluation of a full scale prototype of the thermal management system. We anticipate the prototype device will validate computer modeling efforts on which its design was based, and advance future designs of the thermal management system."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["7383093 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Innovative Thermal Management of Electronics Used in Oil Well Logging"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Joshi, Yogendra"],"dc:contributor.committeemember":["Bruce Storm","Ghiaasiaan, S. Mostafa"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Jakaboski, Juan-Carlos"],"dc:date.accessioned":["2005-09-16T15:19:15Z"],"dc:date.available":["2005-09-16T15:19:15Z"],"dc:date.issued":["2004-05-14"],"dc:description.abstract":["The oil and gas industries use sophisticated logging tools during and after drilling. These logging tools employ internal electronics for sensing viscosity, pressure, temperature, and other important quantities. To protect the sensitive electronics, which typically have a maximum allowable temperature of 100 㬠they are shielded and insulated from the harsh external drilling environment. The insulation reduces the external heat input, but it also makes rejection of the heat generated within the electronics challenging. Electronic component failures promoted by elevated temperatures, and thermal stress, require a time consuming and expensive logging tool replacement process. Better thermal management of the electronics in logging tools promises to save oil and gas companies time and money. This research focuses on this critical thermal management challenge. Specifically, this thesis describes the design, fabrication, and test of an innovative thermal management system capable of cooling commercial-off-the-shelf electronics for extended periods in harsh ambient temperatures exceeding 200 㮠Resistive heaters embedded in quad-flat-packages simulate the electronics used in oil well logging. A custom high temperature oven facilitates the evaluation of a full scale prototype of the thermal management system. We anticipate the prototype device will validate computer modeling efforts on which its design was based, and advance future designs of the thermal management system."],"dc:description.degree":["M.S."],"dc:format.extent":["7383093 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/7255"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["63ef328b-076b-44b7-92a9-0f7dd03fa1fa"],"dc:relation.ispartofseries":["Master of Science in Mechanical Engineering"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"],"dc:subject":["Oil well logging","Electronics thermal management"],"dc:title":["Innovative Thermal Management of Electronics Used in Oil Well Logging"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T04:54:43Z"}