{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/72614"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/72614","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Design and Comparison of a Powered Back Exosuit for Lifting Tasks","abstract":"Manual labor workers often perform repetitive lifting tasks that have been correlated with increased risk for chronic lower back pain and back injuries. Recently, back exoskeletons have been a popular area of study for potentially mitigating lower back pain from lifting. Most commercially available back exoskeletons are unpowered, passive devices that can reduce lumbar muscle exertion during lifts but lack an external power source to provide positive net work or an intelligent controller to adjust to different lifting conditions. Powered back exoskeletons can potentially solve these problems at the cost of generally being rigid, heavy, and unaccommodating for different lifting postures, particularly asymmetric lifts. A lightweight, cable-driven powered back exosuit is presented to address these issues. The exosuit uses an angle-based impedance controller to provide variable assistance based on user posture. Experimental results using the device across 10 subjects are presented, including EMG, metabolic, and user preference data. The results from the powered back exoskeleton are evaluated against the backX, a commercially available passive back support exoskeleton, and a no-exo control condition. Ultimately, it was determined that both the powered back exoskeleton and backX did not significantly reduce the metabolic cost associated with lifting, but both significantly decreased EMG activation to a similar degree.","abstract_html":"Manual labor workers often perform repetitive lifting tasks that have been correlated with increased risk for chronic lower back pain and back injuries. Recently, back exoskeletons have been a popular area of study for potentially mitigating lower back pain from lifting. Most commercially available back exoskeletons are unpowered, passive devices that can reduce lumbar muscle exertion during lifts but lack an external power source to provide positive net work or an intelligent controller to adjust to different lifting conditions. Powered back exoskeletons can potentially solve these problems at the cost of generally being rigid, heavy, and unaccommodating for different lifting postures, particularly asymmetric lifts. A lightweight, cable-driven powered back exosuit is presented to address these issues. The exosuit uses an angle-based impedance controller to provide variable assistance based on user posture. Experimental results using the device across 10 subjects are presented, including EMG, metabolic, and user preference data. The results from the powered back exoskeleton are evaluated against the backX, a commercially available passive back support exoskeleton, and a no-exo control condition. Ultimately, it was determined that both the powered back exoskeleton and backX did not significantly reduce the metabolic cost associated with lifting, but both significantly decreased EMG activation to a similar degree.","abstract_has_math":false,"creators":["Cullen, Ian T."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Young, Aaron"],"committee_chairs":[],"committee_members":["Mazumdar, Anirban","Sawicki, Gregory"],"year":2022,"date_issued":"2022-08-23","date_published":"2022-08-23","updated_at":"2026-11-19T04:25:15Z","subjects":["Wearable robotics","Robotics","Exoskeletons","Lower back pain"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/72614","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/72614","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F72614","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Young, Aaron"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Mazumdar, Anirban","Sawicki, Gregory"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Cullen, Ian T."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-09-06T19:43:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-09-06T19:43:57Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-08"]},{"key":"dc:date.issued","label":"Date","values":["2022-08-23"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2022"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2023-09-06T19:43:57Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["7f9a67d3-b78f-45e2-a5e9-d9a1650849db"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wearable robotics","Robotics","Exoskeletons","Lower back pain"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/72614"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Manual labor workers often perform repetitive lifting tasks that have been correlated with increased risk for chronic lower back pain and back injuries. Recently, back exoskeletons have been a popular area of study for potentially mitigating lower back pain from lifting. Most commercially available back exoskeletons are unpowered, passive devices that can reduce lumbar muscle exertion during lifts but lack an external power source to provide positive net work or an intelligent controller to adjust to different lifting conditions. Powered back exoskeletons can potentially solve these problems at the cost of generally being rigid, heavy, and unaccommodating for different lifting postures, particularly asymmetric lifts. A lightweight, cable-driven powered back exosuit is presented to address these issues. The exosuit uses an angle-based impedance controller to provide variable assistance based on user posture. Experimental results using the device across 10 subjects are presented, including EMG, metabolic, and user preference data. The results from the powered back exoskeleton are evaluated against the backX, a commercially available passive back support exoskeleton, and a no-exo control condition. Ultimately, it was determined that both the powered back exoskeleton and backX did not significantly reduce the metabolic cost associated with lifting, but both significantly decreased EMG activation to a similar degree."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design and Comparison of a Powered Back Exosuit for Lifting Tasks"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Young, Aaron"],"dc:contributor.committeemember":["Mazumdar, Anirban","Sawicki, Gregory"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Cullen, Ian T."],"dc:date.accessioned":["2023-09-06T19:43:57Z"],"dc:date.available":["2023-09-06T19:43:57Z"],"dc:date.created":["2022-08"],"dc:date.issued":["2022-08-23"],"dc:date.submitted":["August 2022"],"dc:date.updated":["2023-09-06T19:43:57Z"],"dc:description.abstract":["Manual labor workers often perform repetitive lifting tasks that have been correlated with increased risk for chronic lower back pain and back injuries. Recently, back exoskeletons have been a popular area of study for potentially mitigating lower back pain from lifting. Most commercially available back exoskeletons are unpowered, passive devices that can reduce lumbar muscle exertion during lifts but lack an external power source to provide positive net work or an intelligent controller to adjust to different lifting conditions. Powered back exoskeletons can potentially solve these problems at the cost of generally being rigid, heavy, and unaccommodating for different lifting postures, particularly asymmetric lifts. A lightweight, cable-driven powered back exosuit is presented to address these issues. The exosuit uses an angle-based impedance controller to provide variable assistance based on user posture. Experimental results using the device across 10 subjects are presented, including EMG, metabolic, and user preference data. The results from the powered back exoskeleton are evaluated against the backX, a commercially available passive back support exoskeleton, and a no-exo control condition. Ultimately, it was determined that both the powered back exoskeleton and backX did not significantly reduce the metabolic cost associated with lifting, but both significantly decreased EMG activation to a similar degree."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/72614"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["7f9a67d3-b78f-45e2-a5e9-d9a1650849db"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:subject":["Wearable robotics","Robotics","Exoskeletons","Lower back pain"],"dc:title":["Design and Comparison of a Powered Back Exosuit for Lifting Tasks"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T04:25:15Z"}