{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/72664"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/72664","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Characterization and Validation of a Proton Minibeam System and Evaluation of Treatment Planning Systems","abstract":"Spatially fractionated radiation therapy (SFRT) has been used to deliver radiation therapy since the early 1900s, with renewed interest in the last few decades. Proton SFRT is a recent proposal which is used in limited clinical circumstances. Further research on proton mini- and microbeams have been shown to have an increased therapeutic index when compared to traditional SFRT. Despite the body of research showing its biologic benefits compared to other more traditional methods of radiation therapy, proton minibeam radiation therapy (pMBRT) is not currently used clinically. This work attempts to model a pMBRT minibeam and assess the accuracy of Class-II Monte Carlo algorithms in generating clinical treatment plans. This work characterized a collimated proton minibeam system using TOPAS simulations and experimental measurements. It then used the open-source treatment planning system (TPS), MCSquare, to compare the results of Class-II Monte Carlo methods to more extensive Monte Carlo simulations and measurements. A simple clinical case with an anthropomorphic phantom was used to test MCSquare end-to-end. This work further characterized the secondary neutral particles present in a collimated minibeam system as well as the impact the collimator has on linear energy transfer (LET). Overall, measurements showed high agreement with TOPAS simulations when characterizing the minibeam. The TPS results showed high agreement with TOPAS and measurements, with noted differences due to lack of secondary neutral particle transport. The end-to-end test showed high agreement with a gamma analysis. The secondary neutral particles and LET characterization showed high agreement between measurements and TOPAS simulations and the impact of the collimator on these quantities wasstudied.","abstract_html":"Spatially fractionated radiation therapy (SFRT) has been used to deliver radiation therapy since the early 1900s, with renewed interest in the last few decades. Proton SFRT is a recent proposal which is used in limited clinical circumstances. Further research on proton mini- and microbeams have been shown to have an increased therapeutic index when compared to traditional SFRT. Despite the body of research showing its biologic benefits compared to other more traditional methods of radiation therapy, proton minibeam radiation therapy (pMBRT) is not currently used clinically. This work attempts to model a pMBRT minibeam and assess the accuracy of Class-II Monte Carlo algorithms in generating clinical treatment plans. This work characterized a collimated proton minibeam system using TOPAS simulations and experimental measurements. It then used the open-source treatment planning system (TPS), MCSquare, to compare the results of Class-II Monte Carlo methods to more extensive Monte Carlo simulations and measurements. A simple clinical case with an anthropomorphic phantom was used to test MCSquare end-to-end. This work further characterized the secondary neutral particles present in a collimated minibeam system as well as the impact the collimator has on linear energy transfer (LET). Overall, measurements showed high agreement with TOPAS simulations when characterizing the minibeam. The TPS results showed high agreement with TOPAS and measurements, with noted differences due to lack of secondary neutral particle transport. The end-to-end test showed high agreement with a gamma analysis. The secondary neutral particles and LET characterization showed high agreement between measurements and TOPAS simulations and the impact of the collimator on these quantities wasstudied.","abstract_has_math":false,"creators":["Stanforth, Alexander"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Wang, C.-K. Chris"],"committee_chairs":[],"committee_members":["Biegalski, Steve","Erickson, Anna","Lin, Liyong","Langen, Katja"],"year":2023,"date_issued":"2023-05-16","date_published":"2023-05-16","updated_at":"2026-11-19T04:57:30Z","subjects":["Proton","minibeam"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/72664","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/72664","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F72664","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wang, C.-K. Chris"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Biegalski, Steve","Erickson, Anna","Lin, Liyong","Langen, Katja"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Stanforth, Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-09-06T19:46:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-09-06T19:46:36Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-08"]},{"key":"dc:date.issued","label":"Date","values":["2023-05-16"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2023-09-06T19:46:37Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Proton","minibeam"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/72664"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Spatially fractionated radiation therapy (SFRT) has been used to deliver radiation therapy since the early 1900s, with renewed interest in the last few decades. Proton SFRT is a recent proposal which is used in limited clinical circumstances. Further research on proton mini- and microbeams have been shown to have an increased therapeutic index when compared to traditional SFRT. Despite the body of research showing its biologic benefits compared to other more traditional methods of radiation therapy, proton minibeam radiation therapy (pMBRT) is not currently used clinically. This work attempts to model a pMBRT minibeam and assess the accuracy of Class-II Monte Carlo algorithms in generating clinical treatment plans. This work characterized a collimated proton minibeam system using TOPAS simulations and experimental measurements. It then used the open-source treatment planning system (TPS), MCSquare, to compare the results of Class-II Monte Carlo methods to more extensive Monte Carlo simulations and measurements. A simple clinical case with an anthropomorphic phantom was used to test MCSquare end-to-end. This work further characterized the secondary neutral particles present in a collimated minibeam system as well as the impact the collimator has on linear energy transfer (LET). Overall, measurements showed high agreement with TOPAS simulations when characterizing the minibeam. The TPS results showed high agreement with TOPAS and measurements, with noted differences due to lack of secondary neutral particle transport. The end-to-end test showed high agreement with a gamma analysis. The secondary neutral particles and LET characterization showed high agreement between measurements and TOPAS simulations and the impact of the collimator on these quantities wasstudied."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization and Validation of a Proton Minibeam System and Evaluation of Treatment Planning Systems"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wang, C.-K. Chris"],"dc:contributor.committeemember":["Biegalski, Steve","Erickson, Anna","Lin, Liyong","Langen, Katja"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Stanforth, Alexander"],"dc:date.accessioned":["2023-09-06T19:46:36Z"],"dc:date.available":["2023-09-06T19:46:36Z"],"dc:date.created":["2023-08"],"dc:date.issued":["2023-05-16"],"dc:date.submitted":["August 2023"],"dc:date.updated":["2023-09-06T19:46:37Z"],"dc:description.abstract":["Spatially fractionated radiation therapy (SFRT) has been used to deliver radiation therapy since the early 1900s, with renewed interest in the last few decades. Proton SFRT is a recent proposal which is used in limited clinical circumstances. Further research on proton mini- and microbeams have been shown to have an increased therapeutic index when compared to traditional SFRT. Despite the body of research showing its biologic benefits compared to other more traditional methods of radiation therapy, proton minibeam radiation therapy (pMBRT) is not currently used clinically. This work attempts to model a pMBRT minibeam and assess the accuracy of Class-II Monte Carlo algorithms in generating clinical treatment plans. This work characterized a collimated proton minibeam system using TOPAS simulations and experimental measurements. It then used the open-source treatment planning system (TPS), MCSquare, to compare the results of Class-II Monte Carlo methods to more extensive Monte Carlo simulations and measurements. A simple clinical case with an anthropomorphic phantom was used to test MCSquare end-to-end. This work further characterized the secondary neutral particles present in a collimated minibeam system as well as the impact the collimator has on linear energy transfer (LET). Overall, measurements showed high agreement with TOPAS simulations when characterizing the minibeam. The TPS results showed high agreement with TOPAS and measurements, with noted differences due to lack of secondary neutral particle transport. The end-to-end test showed high agreement with a gamma analysis. The secondary neutral particles and LET characterization showed high agreement between measurements and TOPAS simulations and the impact of the collimator on these quantities wasstudied."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/72664"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Nuclear Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:relation.seriesentity":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"],"dc:subject":["Proton","minibeam"],"dc:title":["Characterization and Validation of a Proton Minibeam System and Evaluation of Treatment Planning Systems"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T04:57:30Z"}