{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/72769"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/72769","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Influence of Steel Reinforcement and Boundary Conditions on Cracking in Massive Concrete Caissons","abstract":"The purpose of the experimental research was to characterize and understand the conditions which lead to thermal cracking in massive concrete caisson drilled shafts. Seven circular column specimens with a diameter of 122 cm (48 in) and a height of 91 to 116 cm (36 to 46 in) were constructed with varying boundary conditions to represent likely field conditions of massive drilled concrete caissons. Both commercially available cardboardbased formwork and steel formwork were used. The formwork was surrounded by air, soil, or water. Thermistors were casted at mid-height of each column along the diameter to provide a higher resolution of temperature observation than what is typically required in industry monitoring practice. Cracking was monitored in the columns for up to 33 days after the casting of each specimen. Thermal boundary conditions of the specimens and the presence of reinforcement were found to be highly influential in predicting the formation of cracks. This text also describes a computational procedure to obtain an approximate stress state for massive concrete caisson specimens during early age. Stress states were predicted for larger specimens, up to 244 cm (96 in) in diameter, using predicted thermal data from the software B4CAST. The results show steel reinforcement can, in the presence of high temperatures, cause stress concentrations at the steel-concrete interface which may exceed the early age tensile strength of the concrete.","abstract_html":"The purpose of the experimental research was to characterize and understand the conditions which lead to thermal cracking in massive concrete caisson drilled shafts. Seven circular column specimens with a diameter of 122 cm (48 in) and a height of 91 to 116 cm (36 to 46 in) were constructed with varying boundary conditions to represent likely field conditions of massive drilled concrete caissons. Both commercially available cardboardbased formwork and steel formwork were used. The formwork was surrounded by air, soil, or water. Thermistors were casted at mid-height of each column along the diameter to provide a higher resolution of temperature observation than what is typically required in industry monitoring practice. Cracking was monitored in the columns for up to 33 days after the casting of each specimen. Thermal boundary conditions of the specimens and the presence of reinforcement were found to be highly influential in predicting the formation of cracks. This text also describes a computational procedure to obtain an approximate stress state for massive concrete caisson specimens during early age. Stress states were predicted for larger specimens, up to 244 cm (96 in) in diameter, using predicted thermal data from the software B4CAST. The results show steel reinforcement can, in the presence of high temperatures, cause stress concentrations at the steel-concrete interface which may exceed the early age tensile strength of the concrete.","abstract_has_math":false,"creators":["Wasson, Isaac Hunt"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":["Stewart, Lauren K.","Kahn, Lawrence"],"committee_chairs":[],"committee_members":["Loreto, Giovanni"],"year":2023,"date_issued":"2023-07-31","date_published":"2023-07-31","updated_at":"2026-11-19T06:03:33Z","subjects":["massive concrete","thermal effects","boundary conditions","caissons","circular shafts"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/72769","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/72769","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F72769","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Stewart, Lauren K.","Kahn, Lawrence"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Loreto, Giovanni"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Civil and Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Wasson, Isaac Hunt"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-09-11T13:56:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-09-11T13:56:31Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-08"]},{"key":"dc:date.issued","label":"Date","values":["2023-07-31"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2023-09-11T13:56:32Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["60b8f550-7e84-4d16-9a91-c65a26bac475"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Civil Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["451ac1ce-0dd6-43a5-8843-bae81fd68e33"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["massive concrete","thermal effects","boundary conditions","caissons","circular shafts"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/72769"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of the experimental research was to characterize and understand the conditions which lead to thermal cracking in massive concrete caisson drilled shafts. Seven circular column specimens with a diameter of 122 cm (48 in) and a height of 91 to 116 cm (36 to 46 in) were constructed with varying boundary conditions to represent likely field conditions of massive drilled concrete caissons. Both commercially available cardboardbased formwork and steel formwork were used. The formwork was surrounded by air, soil, or water. Thermistors were casted at mid-height of each column along the diameter to provide a higher resolution of temperature observation than what is typically required in industry monitoring practice. Cracking was monitored in the columns for up to 33 days after the casting of each specimen. Thermal boundary conditions of the specimens and the presence of reinforcement were found to be highly influential in predicting the formation of cracks. This text also describes a computational procedure to obtain an approximate stress state for massive concrete caisson specimens during early age. Stress states were predicted for larger specimens, up to 244 cm (96 in) in diameter, using predicted thermal data from the software B4CAST. The results show steel reinforcement can, in the presence of high temperatures, cause stress concentrations at the steel-concrete interface which may exceed the early age tensile strength of the concrete."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Influence of Steel Reinforcement and Boundary Conditions on Cracking in Massive Concrete Caissons"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Stewart, Lauren K.","Kahn, Lawrence"],"dc:contributor.committeemember":["Loreto, Giovanni"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:contributor.other":["College of Engineering","School of Civil and Environmental Engineering"],"dc:creator":["Wasson, Isaac Hunt"],"dc:date.accessioned":["2023-09-11T13:56:31Z"],"dc:date.available":["2023-09-11T13:56:31Z"],"dc:date.created":["2023-08"],"dc:date.issued":["2023-07-31"],"dc:date.submitted":["August 2023"],"dc:date.updated":["2023-09-11T13:56:32Z"],"dc:description.abstract":["The purpose of the experimental research was to characterize and understand the conditions which lead to thermal cracking in massive concrete caisson drilled shafts. Seven circular column specimens with a diameter of 122 cm (48 in) and a height of 91 to 116 cm (36 to 46 in) were constructed with varying boundary conditions to represent likely field conditions of massive drilled concrete caissons. Both commercially available cardboardbased formwork and steel formwork were used. The formwork was surrounded by air, soil, or water. Thermistors were casted at mid-height of each column along the diameter to provide a higher resolution of temperature observation than what is typically required in industry monitoring practice. Cracking was monitored in the columns for up to 33 days after the casting of each specimen. Thermal boundary conditions of the specimens and the presence of reinforcement were found to be highly influential in predicting the formation of cracks. This text also describes a computational procedure to obtain an approximate stress state for massive concrete caisson specimens during early age. Stress states were predicted for larger specimens, up to 244 cm (96 in) in diameter, using predicted thermal data from the software B4CAST. The results show steel reinforcement can, in the presence of high temperatures, cause stress concentrations at the steel-concrete interface which may exceed the early age tensile strength of the concrete."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/72769"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["60b8f550-7e84-4d16-9a91-c65a26bac475"],"dc:relation.ispartofseries":["Master of Science in Civil Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","88639fad-d3ae-4867-9e7a-7c9e6d2ecc7c"],"dc:relation.seriesentity":["451ac1ce-0dd6-43a5-8843-bae81fd68e33"],"dc:subject":["massive concrete","thermal effects","boundary conditions","caissons","circular shafts"],"dc:title":["Influence of Steel Reinforcement and Boundary Conditions on Cracking in Massive Concrete Caissons"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T06:03:33Z"}